- Description: TeSys GV2 - Circuit breaker - magnetic - 10 A - screw clamp terminals
- Product weight: 0.73 lb(US) (0.33 kg)
- Standards: NF C 79-130, EN 60204, IEC 60947-2, NF C 63-120, IEC 60947-1, VDE 0113, VDE 0660, NF C 63-650
- Device short name: GV2L
- Width: 1.77 in (45 mm)
- Height: 3.5 in (89 mm)
- Depth: 3.82 in (97 mm)
- Protective treatment: TH
- [Ui] rated insulation voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2
- Operating altitude: 6561.68 ft. (2000 m)
- Mechanical durability: 100000 cycles
- Tightening torque: 1.7 N.m on screw clamp terminals
- Connections - terminals: Screw clamp terminals 2 cable(s) 0...0.01 in (1...6 mm) - cable stiffness : solid, Screw clamp terminals 2 cable(s) 0...0.01 in (1.5...6 mm) - cable stiffness : flexible - without cable end, Screw clamp terminals 2 cable(s) 0...0.01 in (1...4 mm) - cable stiffness : flexible - with cable end
- Range: TeSys
- Mounting support: Rail, Plate
- System Voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
- Operating rate: 40 cyc/h
- Product name: TeSys GV2
- Electrical durability: 100000 cycles AC-3 at 415 V
- motor power kW: 3 kW at 400/415 V AC 50/60 Hz, 4 kW at 400/415 V AC 50/60 Hz, 4 kW at 500 V AC 50/60 Hz, 7.5 kWat 690 V AC 50/60 Hz, 5.5 kW at 690 V AC 50/60 Hz
- Utilization category: AC-3 conforming to IEC 60947-4-1, Category A conforming to IEC 60947-2
- Poles description: 3P
- Control type: Rotary knob
- Breaking capacity: 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2, 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
- Mounting position: Horizontal, Vertical
- Mounting mode: By Clips / By Screws
- Product certifications: CSA, GL, BV, LROS (Lloyds register of shipping), RINA, DNV, CCC
- Product or component type: Circuit breaker
- IK degree of protection: IK04
- Device application: Motor
- Ambient air temperature for operation: -4...140 F (-20...60 C)
- Ambient air temperature for storage: -40...176 F (-40...80 C)
- Network type: AC
- Fire resistance: 1760 F (960 C) conforming to IEC 60695-2-1
- Network frequency: 50/60 Hz conforming to IEC 60947-2
- Power dissipation per pole: 1.8 W
- [Ics] rated service short-circuit breaking capacity: 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2, 75 % at 440 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
- Trip unit rating: 10:00 AM
- Trip unit technology: Magnetic
- Rated duty: Continuous conforming to IEC 60947-4-1
- Magnetic tripping current: 138 A
- Mechanical robustness: Shocks 30 Gn conforming to IEC 60068-2-27, Vibrations 5 Gn, 5...150 Hz conforming to IEC 60068-2-6
- Suitability for isolation: Yes conforming to IEC 60947-1
- Phase failure sensitivity: Yes
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on GV2L14 . Santa Clara Systems carries 10,417 items from Telemecanique.
- Tesys Gv2 - Circuit Breaker - Magnetic - 10 A - Screw Clamp Terminals
Alternates
Common Typos
- 6V2114
- 6V21I4
- 6V21L4
- 6V2I14
- 6V2II4
- 6V2IL4
- 6V2L14
- 6V2LI4
- 6V2LL4
- GV2114
- GV21I4
- GV21L4
- GV2I14
- GV2II4
- GV2IL4
- GV2LI4
- GV2LL4
- GVZ114
- GVZ1I4
- GVZ1L4
- GVZI14
- GVZII4
- GVZIL4
- GVZL14
- GVZLI4
- GVZLL4
Appended Numbers
- GV2L14-A
- GV2L14-B
- GV2L14-C
- GV2L14-D
- GV2L14-E
- GV2L14-F
- GV2L14-G
- GV2L14-H
- GV2L14-I
- GV2L14-J
- GV2L14-K
- GV2L14-L
- GV2L14-M
- GV2L14-N
- GV2L14-O
- GV2L14-P
- GV2L14-Q
- GV2L14-R
- GV2L14-S
- GV2L14-T
- GV2L14-U
- GV2L14-V
- GV2L14-W
- GV2L14-X
- GV2L14-Y
- GV2L14-Z
More Products Like This
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier