- Description: TeSys GV2 - Circuit breaker - thermal-magnetic - 4...6.3 A - spring terminals
- Product weight: 0.62 lb(US) (0.28 kg)
- IP degree of protection: IP20 conforming to IEC 60529
- Standards: NF C 63-650, VDE 0113, IEC 60947-4-1, NF C 79-130, UL 508, EN 60204, CSA C22.2, IEC 60947-2, IEC 60947-1, VDE 0660, NF C 63-120
- Device short name: GV2ME
- Width: 1.77 in (45 mm)
- Height: 3.98 in (101 mm)
- Depth: 3.08 in (78.2 mm)
- Protective treatment: TH
- [Ui] rated insulation voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2
- Operating altitude: 6561.68 ft. (2000 m)
- Mechanical durability: 100000 cycles
- Connections - terminals: Spring terminals 2 cable(s) 0...0.01 in (1...6 mm) - cable stiffness : solid, Spring terminals 2 cable(s) 0...0.01 in (1.5...4 mm) - cable stiffness : flexible - without cable end
- Range: TeSys
- Mounting support: Rail
- [Ith] conventional free air thermal current: 6.3 A conforming to IEC 60947-4-1
- System Voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
- Operating rate: 25 cyc/h
- Product name: TeSys GV2
- Electrical durability: 100000 cycles AC-3 at 440 V
- motor power kW: 3 kW at 500 V AC 50/60 Hz, 2.2 kW at 400/415 V AC 50/60 Hz
- Utilization category: AC-3 conforming to IEC 60947-4-1, Category A conforming to IEC 60947-2
- Poles description: 3P
- Control type: Push-button
- Breaking capacity: 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
- Mounting position: Vertical, Horizontal
- Network type: AC
- Product certifications: DNV, UL, RINA, TSE, CEBEC, EZU, SETI, GL, CSA, EAC, LROS (Lloyds register of shipping), BV, ATEX, CCC
- Product or component type: Circuit breaker
- Network frequency: 50/60 Hz conforming to IEC 60947-4-1
- Device application: Motor
- Mounting mode: By Clips / By Screws
- IK degree of protection: IK04
- Trip unit technology: Thermal-magnetic
- Ambient air temperature for operation: -4...140 F (-20...60 C)
- Ambient air temperature for storage: -40...176 F (-40...80 C)
- Fire resistance: 1760 F (960 C) conforming to IEC 60695-2-1
- [Ics] rated service short-circuit breaking capacity: 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2, 75 %at 690 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
- [In] rated current: 4...6.3 A
- Trip unit rating: 4...6.3 A
- Magnetic tripping current: 78 A
- Power dissipation per pole: 2.5 W
- Rated duty: Continuous conforming to IEC 60947-4-1
- Suitability for isolation: Yes conforming to IEC 60947-1
- Phase failure sensitivity: Yes conforming to IEC 60947-4-1
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on GV2ME103 . Santa Clara Systems carries 10,327 items from Telemecanique.
- Tesys Gv2 - Circuit Breaker - Thermal-Magnetic - 4...6.3 A - Spring Terminals
Alternates
Common Typos
- 6V2ME103
- 6V2ME1O3
- 6V2MEI03
- 6V2MEIO3
- 6V2MEL03
- 6V2MELO3
- 6VZME103
- 6VZME1O3
- 6VZMEI03
- 6VZMEIO3
- 6VZMEL03
- 6VZMELO3
- GV2ME1O3
- GV2MEI03
- GV2MEIO3
- GV2MEL03
- GV2MELO3
- GVZME103
- GVZME1O3
- GVZMEI03
- GVZMEIO3
- GVZMEL03
- GVZMELO3
Appended Numbers
- GV2ME103-A
- GV2ME103-B
- GV2ME103-C
- GV2ME103-D
- GV2ME103-E
- GV2ME103-F
- GV2ME103-G
- GV2ME103-H
- GV2ME103-I
- GV2ME103-J
- GV2ME103-K
- GV2ME103-L
- GV2ME103-M
- GV2ME103-N
- GV2ME103-O
- GV2ME103-P
- GV2ME103-Q
- GV2ME103-R
- GV2ME103-S
- GV2ME103-T
- GV2ME103-U
- GV2ME103-V
- GV2ME103-W
- GV2ME103-X
- GV2ME103-Y
- GV2ME103-Z
More Products Like This
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier