• Telemecanique GV3 P13 TeSys GV3 - Circuit breaker - thermal-magnetic - 9?13A - EverLink BTR connectors Product Image
  • Telemecanique GV3 P13 TeSys GV3 - Circuit breaker - thermal-magnetic - 9?13A - EverLink BTR connectors Product Image
  • Telemecanique GV3 P13 TeSys GV3 - Circuit breaker - thermal-magnetic - 9?13A - EverLink BTR connectors Product Image
  • Telemecanique GV3 P13 TeSys GV3 - Circuit breaker - thermal-magnetic - 9?13A - EverLink BTR connectors Product Image
  • Telemecanique GV3 P13 Barcode

GV3P13

Get a Quote

Current response time:

By 5AM PT on Friday
  • Description: TeSys GV3 - Circuit breaker - thermal-magnetic - 9?13A - EverLink BTR connectors
  • Product weight: 2.12 lb(US) (0.96 kg)
  • IP degree of protection: IP20 conforming to IEC 60529
  • Standards: EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-2, CSA C22.2 No 14-05 type E, UL 508 type E
  • Device short name: GV3P
  • Width: 2.17 in (55 mm)
  • Height: 5.2 in (132 mm)
  • Depth: 5.35 in (136 mm)
  • Protective treatment: TH
  • [Ui] rated insulation voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
  • [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2
  • Operating altitude: 9842.52 ft. (3000 m)
  • Mechanical durability: 50000 cycles
  • Tightening torque: 8 N.m - on EverLink BTR screw connectors- cable 35 mm, 44.25 lbf.in (5 N.m) - on EverLink BTR screw connectors- cable 0.04 in (25 mm)
  • Connections - terminals: EverLink BTR screw connectors 2 cable(s) 0...0.04 in (1...25 mm) - cable stiffness : solid, EverLink BTR screw connectors 2 cable(s) 0...0.04 in (1...25 mm) - cable stiffness : flexible - without cable end, EverLink BTR screw connectors 2 cable(s) 0...0.04 in (1...25 mm) - cable stiffness : flexible - with cable end
  • Range: TeSys
  • Mounting support: Plate, Rail
  • [Ith] conventional free air thermal current: 13 A conforming to IEC 60947-4-1
  • System Voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
  • Operating rate: 25 cyc/h
  • Product name: TeSys GV3
  • Electrical durability: 50000 cycles AC-3 at 440 V In
  • motor power kW: 11 kW at 690 V AC 50/60 Hz, 7.5 kW at 500 V AC 50/60 Hz, 5.5 kW at 400/415 V AC 50/60 Hz
  • Utilization category: AC-3 conforming to IEC 60947-4-1, Category A conforming to IEC 60947-2
  • Poles description: 3P
  • Control type: Rotary knob
  • Breaking capacity: 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2, 12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
  • Mounting position: Horizontal, Vertical
  • Network type: AC
  • Product certifications: RINA, GL, LROS (pending), CCC, DNV, CSA, BV, UL, EAC, ATEX
  • Product or component type: Circuit breaker
  • Network frequency: 50/60 Hz conforming to IEC 60947-4-1
  • Device application: Motor
  • Mounting mode: By Clips / By Screws
  • IK degree of protection: IK09
  • Trip unit technology: Thermal-magnetic
  • Ambient air temperature for operation: -4...140 F (-20...60 C)
  • Ambient air temperature for storage: -40...176 F (-40...80 C)
  • Fire resistance: 1760 F (960 C) conforming to IEC 60695-2-1
  • [Ics] rated service short-circuit breaking capacity: 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2, 50 %at 500 V AC 50/60 Hz conforming to IEC 60947-2, 50 %at 690 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
  • [In] rated current: 9...13 A
  • Trip unit rating: 9...13 A
  • Magnetic tripping current: 182 A
  • Power dissipation per pole: 8 W
  • Rated duty: Continuous conforming to IEC 60947-4-1
  • Suitability for isolation: Yes conforming to IEC 60947-1
  • Phase failure sensitivity: Yes conforming to IEC 60947-4-1
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on GV3P13 . Santa Clara Systems carries 10,327 items from Telemecanique.
  • Tesys Gv3 - Circuit Breaker - Thermal-Magnetic - 9?13a - Everlink Btr Connectors

Alternates

    Common Typos

    • 6V3P13
    • 6V3PI3
    • 6V3PL3
    • GV3PI3
    • GV3PL3

    Appended Numbers

    • GV3P13-A
    • GV3P13-B
    • GV3P13-C
    • GV3P13-D
    • GV3P13-E
    • GV3P13-F
    • GV3P13-G
    • GV3P13-H
    • GV3P13-I
    • GV3P13-J
    • GV3P13-K
    • GV3P13-L
    • GV3P13-M
    • GV3P13-N
    • GV3P13-O
    • GV3P13-P
    • GV3P13-Q
    • GV3P13-R
    • GV3P13-S
    • GV3P13-T
    • GV3P13-U
    • GV3P13-V
    • GV3P13-W
    • GV3P13-X
    • GV3P13-Y
    • GV3P13-Z

    More Products Like This

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo