• Efector SBN246 Barcode

SBN246

Let Us Find It

Current response time:

By 5AM PT on Friday
  • Description: Flow Meter | SBN11IF0FRKG
  • Output Function: Normally Open / Closed; (Configurable)
  • Material: Stainless Steel (1.4404 / 316L); Pbt+Pc-Gf30; Pbt-Gf20; Pc; Brass Chemically Nickel-Plated
  • Resolution: 10 Gph 0.1 Gpm
  • Media: Water; Glycol Solutions; Coolants; Oil
  • Medium Temperature [F]: 14...212
  • Pressure Rating [Bar]: 25
  • Mawp (For Applications According To Crn) [Bar]: 25
  • Operating Voltage [V]: 18...30 Dc; (According To En 50178 Selv/Pelv)
  • Current Consumption [Ma]: < 50
  • Protection Class: Iii
  • Reverse Polarity Protection: Yes
  • Power-On Delay Time [S]: < 3
  • Number Of Inputs And Outputs: Number Of Digital Outputs: 2; Number Of Analog Outputs: 1
  • Total Number Of Outputs: 2
  • Output Signal: Switching Signal; Analog Signal; Frequency Signal; Io-Link; (Configurable)
  • Number Of Digital Outputs: 2
  • Max. Voltage Drop Switching Output Dc [V]: 2
  • Permanent Current Rating Of Switching Output Dc [Ma]: 150; (Per Output 2 X 200 (...60 C); 2 X 250 (...40 C))
  • Switching Cycles (Mechanical): 10 Million
  • Number Of Analog Outputs: 1
  • Analog Current Output [Ma]: 4...20
  • Max. Load [?]: 500
  • Short-Circuit Protection: Yes
  • Overload Protection: Yes
  • Frequency Of The Output [Hz]: 0...10000
  • Measuring Range [Gph]: 30...1620
  • Display Range: 0...1940 Gph 0...32.4 Gpm
  • Set Point Sp: 10...1620 Gph 0.2...27 Gpm
  • Reset Point Rp: 0...1610 Gph 0...26.8 Gpm
  • Frequency End Point, Fep: 110...1620 Gph 1.8...27 Gpm
  • In Steps Of: 10 Gph 0.1 Gpm
  • Frequency At The End Point Frp [Hz]: 10...10000
  • Measuring Dynamics: 0.0763888888888889
  • Measuring Range [F]: 14...212
  • Display Range [F]: -26...252
  • Resolution [F]: 2
  • Set Point Sp [F]: 16...212
  • Reset Point Rp [F]: 14...210
  • In Steps Of [F]: 2
  • Frequency Start Point, Fsp [F]: 14...172
  • Frequency End Point, Fep [F]: 54...212
  • Accuracy (In The Measuring Range): (4 % Mw + 1 % Mew); (Q > 2 L/Min; Medium And Operating Temperature: +22 C 4K)
  • Repeatability: 1 % Mew
  • Temperature Drift: 0,029 C / K
  • Accuracy [K]: 3 K (25C; Q > 1 L/Min)
  • Response Time [S]: 0.01
  • Damping For The Switching Output Dap [S]: 0...5
  • Damping For The Analog Output Daa [S]: 0...5
  • Dynamic Response T05 / T09 [S]: T09 = 120 (Q > 1 L/Min)
  • Parameter Setting Options: Hysteresis / Window; Normally Open / Closed; Switching Logic; Current Output; Medium Selection; Damping For The Switching Output / Analog Output; Display Can Be Rotated And Switched Off; Standard Unit Of Measurement; Process Value Color
  • Communication Interface: Io-Link
  • Transmission Type: Com2 (38,4 Kbaud)
  • Io-Link Revision: 1.1
  • Sdci Standard: Iec 61131-9 Cdv
  • Io-Link Device Id: 568 D / 0238 H
  • Profiles: Smart Sensor: Process Data Variable; Device Identification
  • Sio Mode: Yes
  • Required Master Port Class: A
  • Process Data Analogue: 2
  • Process Data Binary: 2
  • Min. Process Cycle Time [Ms]: 5
  • Ambient Temperature [F]: 32...140
  • Storage Temperature [F]: 5...176
  • Protection: Ip 65; Ip 67
  • Emc: Din En 61000-6-2 Din En 61000-6-3
  • Shock Resistance: Din En 60068-2-27 20 G (11 Ms)
  • Vibration Resistance: Din En 60068-2-6 5 G (10...2000 Hz)
  • Ul Approval: Ul Approval Number I006
  • Pressure Equipment Directive: Sound Engineering Practice; Can Be Used For Group 2 Fluids; Group 1 Fluids On Request
  • Materials (Wetted Parts): Stainless Steel (1.4401 / 316); Stainless Steel (1.4404 / 316L); Brass (2.0371); Brass Chemically Nickel-Plated; Pps; O-Ring: Fkm
  • Process Connection: Threaded Connection 1 Npt
  • Display: Display Unit 3 X Led, Green Switching Status 2 X Led, Yellow Measured Values Alphanumeric Display, Red/Green 4-Digit Programming Alphanumeric Display, 4-Digit
  • Connection: Connector: 1 X M12; Contacts: Gold-Plated
  • Pressure Loss: Dp Pressure Loss Q Volumetric Flow Quantity
  • Alternate Manufacturer Name: IFM
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on SBN246 . Santa Clara Systems carries 2,278 items from Efector.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.

Alternates

  • SBN11IF0FRKG

Common Typos

  • 58N246
  • 58N24G
  • 58NZ46
  • 58NZ4G
  • 5BN246
  • 5BN24G
  • 5BNZ46
  • 5BNZ4G
  • S8N246
  • S8N24G
  • S8NZ46
  • S8NZ4G
  • SBN24G
  • SBNZ46
  • SBNZ4G

Appended Numbers

  • SBN246-A
  • SBN246-B
  • SBN246-C
  • SBN246-D
  • SBN246-E
  • SBN246-F
  • SBN246-G
  • SBN246-H
  • SBN246-I
  • SBN246-J
  • SBN246-K
  • SBN246-L
  • SBN246-M
  • SBN246-N
  • SBN246-O
  • SBN246-P
  • SBN246-Q
  • SBN246-R
  • SBN246-S
  • SBN246-T
  • SBN246-U
  • SBN246-V
  • SBN246-W
  • SBN246-X
  • SBN246-Y
  • SBN246-Z

More Products Like This

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo