- Description: soft starter for asynchronous motor - ATS48 - 156 A - 208..690 V - 37..160 KW
- Product weight: 27.34 lb(US) (12.4 kg)
- Range of product: Altistart 48
- IP degree of protection: IP00
- Standards: EN/IEC 60947-4-2
- Device short name: ATS48
- Width: 7.87 in (200 mm)
- Height: 13.39 in (340 mm)
- Depth: 10.43 in (265 mm)
- Operating altitude: <= 3280.84 ft. (1000 m) without derating, > 3280.84...6561.68 ft. (> 1000...2000 m) with current derating of 2.2 % per additional 100 m
- [Uc] control circuit voltage: 110 - 15 % to 230 + 10 %, 50/60 Hz
- Vibration resistance: 1 gn (f = 13...200 Hz) conforming to EN/IEC 60068-2-6, 1.5 mm (f = 2...13 Hz) conforming to EN/IEC 60068-2-6
- Shock resistance: 15 gn 11 ms conforming to EN/IEC 60068-2-27
- motor power kW: 110 kW at 500 V for standard applications, 110 kW at 525 V for standard applications, 110 kW at 660 V for severe applications, 110 kW at 690 V for severe applications, 132 kW at 660 V for standard applications, 160 kW at 690 V for standard applications, 37 kW at 230 V for severe applications, 45 kW at 230 V for standard applications, 75 kW at 400 V for severe applications, 75 kW at 440 V for severe applications, 90 kW at 400 V for standard applications, 90 kW at 440 V for standard applications, 90 kW at 500 V for severe applications, 90 kW at 525 V for severe applications
- Utilization category: AC-53A
- [Us] rated supply voltage: 208...690 V (- 15...10 %)
- Relative humidity: 0...95 % without condensation or dripping water conforming to EN/IEC 60068-2-3
- Protection type: Phase failure (line), Thermal protection (motor), Thermal protection (starter)
- Assembly style: With heat sink
- Electromagnetic compatibility: Conducted and radiated emissions conforming to IEC 60947-4-2 level A, Conducted and radiated emissions conforming to IEC 60947-4-2 level B, Damped oscillating waves conforming to IEC 61000-4-12 level 3, Electrostatic discharge conforming to IEC 61000-4-2 level 3, Immunity to electrical transients conforming to IEC 61000-4-4 level 4, Immunity to radiated radio-electrical interference conforming to IEC 61000-4-3 level 3, Voltage/current impulse conforming to IEC 61000-4-5 level 3
- Product or component type: Soft starter
- Function available: External bypass (optional)
- Product destination: Asynchronous motors
- Supply voltage limits: 177...759 V
- Product certifications: NOM 117, CSA, UL, DNV, CCC, SEPRO, TCF, C-Tick, GOST
- Product specific application: Heavy duty industry and pumps
- Supply frequency: 50...60 Hz (- 5...5 %)
- Network frequency: 47.5...63 Hz
- Device connection: In the motor supply line
- Noise level: 50 dB
- Factory setting current: 156 A
- Pollution degree: Level 3 conforming to IEC 60664-1
- Motor power hp: 100 hp at 460 V for severe applications, 125 hp at 460 V for standard applications, 125 hp at 575 V for severe applications, 150 hp at 575 V for standard applications, 40 hp at 208 V for severe applications, 50 hp at 208 V for standard applications, 50 hp at 230 V for severe applications, 60 hp at 230 V for standard applications
- power dissipation in W: For standard applications 391 W, For standard applications 479 W
- Control circuit consumption: 30 W
- Ambient air temperature for operation: 14...104 F (-10...40 C) without derating, > 104...140 F (> 40...60 C) with current derating of 2 % per C
- Discrete output number: 2
- Ambient air temperature for storage: -13...158 F (-25...70 C)
- Type of start: Start with torque control (current limited to 5 In)
- Discrete output type: (LO1) logic output 0 V common configurable, (LO2) logic output 0 V common configurable, (R1) relay outputs fault relay NO, (R2) relay outputs end of starting relay NO, (R3) relay outputs motor powered NO
- IcL starter rating: 140 A for standard applications, 170 A for standard applications
- Output absolute accuracy precision: +/- 5 %
- Minimum switching current: Relay outputs 10 mA at 6 V DC
- Maximum switching current: Logic output 0.2 A at 30 V DC, Relay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5, L/R = 20 ms, Relay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5, L/R = 20 ms
- Discrete input number: 5
- Discrete input type: PTC, 750 Ohm at 77 F (25 C), (Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
- Discrete input voltage: 24 V (<= 30 V)
- Discrete input logic: Positive logic (Stop, Run, LI3, LI4) state 0 < 5 V and <= 2 mA, state 1 > 11 V and >= 5 mA
- Supply inrush current: Adjustable 0.4...1.3 Icl
- Analogue output type: (AO) current output 0-20 mA or 4-20 mA <= 500 Ohm
- Communication port protocol: Modbus
- Connector type: 1 RJ45
- Communication data link: Serial
- Physical interface: RS485 multidrop
- Transmission rate: 4800, 9600 or 19200 bps
- Installed device: 31
- Marking: CE
- Type of cooling: Forced convection
- Operating position: Vertical +/- 10 degree
- Power range: 30...50 kW at 200...240 V 3 phases, 55...100 kW at 380...440 V 3 phases, 110...220 kW at 480...500 V 3 phases
- Motor starter type: Soft starter
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on ATS48C17Y . Santa Clara Systems carries 10,327 items from Telemecanique.
- Soft Starter For Asynchronous Motor - Ats48 - 156 A - 208..690 V - 37..160 Kw
Alternates
Common Typos
- AT548C17Y
- AT548CI7Y
- AT548CL7Y
- AT54BC17Y
- AT54BCI7Y
- AT54BCL7Y
- ATS48CI7Y
- ATS48CL7Y
- ATS4BC17Y
- ATS4BCI7Y
- ATS4BCL7Y
Appended Numbers
- ATS48C17Y-A
- ATS48C17Y-B
- ATS48C17Y-C
- ATS48C17Y-D
- ATS48C17Y-E
- ATS48C17Y-F
- ATS48C17Y-G
- ATS48C17Y-H
- ATS48C17Y-I
- ATS48C17Y-J
- ATS48C17Y-K
- ATS48C17Y-L
- ATS48C17Y-M
- ATS48C17Y-N
- ATS48C17Y-O
- ATS48C17Y-P
- ATS48C17Y-Q
- ATS48C17Y-R
- ATS48C17Y-S
- ATS48C17Y-T
- ATS48C17Y-U
- ATS48C17Y-V
- ATS48C17Y-W
- ATS48C17Y-X
- ATS48C17Y-Y
- ATS48C17Y-Z
More Products Like This
-
ATS 48C14YU
Telemecanique
-
ATS 48C11Q
Telemecanique
-
ATS 48C21Q
Telemecanique
-
ATS 48C25Y
Telemecanique
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier