- Description: TeSys GV7 - circuit breaker - 3P - AC-3 - 12...20 A - thermal-magnetic
- Product weight: 4.43 lb(US) (2.01 kg)
- IP degree of protection: IP405 with terminal shrouds conforming to IEC 60529
- Standards: VDE 0113EN/IEC 60947-2NF C 79-130NF C 63-650EN/IEC 60947-1VDE 0660EN/IEC 60947-4-1NF C 63-120
- Device short name: GV7R
- Width: 4.13 in (105 mm)
- Height: 6.34 in (161 mm)
- Depth: 4.37 in (111 mm)
- Protective treatment: TC
- [Ui] rated insulation voltage: 750 V AC 50/60 Hz conforming to IEC 60947-2
- [Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947-2
- Operating altitude: 6561.68 ft. (2000 m)
- Mechanical durability: 50000 cycles
- Tightening torque: 10 N.m - on screw - screw M615 N.m - on bare cable connectors- cable 1.5...95 mm²
- Connections - terminals: BarsCable with lug - external diameter : 10 mmBare cable connectors 1.5...95 mm²Screw
- Range: TeSys
- Mounting support: Kit for fixing the switchgearFlushRailPanel mounting
- [Ith] conventional free air thermal current: 20 A conforming to IEC 60947-4-1
- System Voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
- Operating rate: 25 cyc/h
- Product name: TeSys GV7
- Electrical durability: 30000 cycles AC-3 at 440 V In50000 cycles AC-3 at 440 V In/2
- motor power kW: 11 kW at 500 V AC 50/60 Hz11 kW at 660/690 V AC 50/60 Hz15 kW at 660/690 V AC 50/60 Hz9 kW at 400/415 V AC 50/60 Hz9 kW at 500 V AC 50/60 Hz7.5 kW at 400/415 V AC 50/60 Hz
- Utilization category: AC-3 conforming to IEC 60947-4-1
- Poles description: 3P
- Control type: Rocker lever
- Breaking capacity: 18 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 400...415 V AC 50/60 Hz conforming to IEC 60947-28 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-236 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-285 kA Icu at 230...240 V AC 50/60 Hz conforming to IEC 60947-2
- Mounting position: Vertical
- Mounting mode: By Clips / By Screws
- Product certifications: ULDNV
- Product or component type: Circuit breaker
- Device application: Motor
- Pollution degree: 3
- Ambient air temperature for operation: -13...158 °F (-25...70 °C)
- Network type: AC
- Ambient air temperature for storage: -67...203 °F (-55...95 °C)
- Fire resistance: 1760 °F (960 °C) conforming to IEC 60695-2-1
- Network frequency: 50/60 Hz conforming to IEC 60947-4-1
- Power dissipation per pole: 5 W
- [Ics] rated service short-circuit breaking capacity: 100 % at 230...240 V AC 50/60 Hz conforming to IEC 60947-2100 % at 400...415 V AC 50/60 Hz conforming to IEC 60947-2100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
- Power dissipation: 5 W
- Trip unit rating: 12...20 A
- Trip unit technology: Thermal-magnetic
- Rated duty: Continuous conforming to IEC 60947-4-1
- Connection pitch: 1.38 in (35 mm) without spreaders1.77 in (45 mm) with spreaders
- Mechanical robustness: Shocks 15 Gn for 11 ms conforming to IEC 60068-2-27Vibrations 2.5 Gn, 0...25 Hz conforming to IEC 60068-2-6
- Suitability for isolation: Yes conforming to IEC 60947-1
- Phase failure sensitivity: Yes conforming to IEC 60947-4-1 § 7-2-1-5-2
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on GV7RE20 . Santa Clara Systems carries 10,416 items from Telemecanique.
- Tesys Gv7 - Circuit Breaker - 3p - Ac-3 - 12...20 A - Thermal-Magnetic
Alternates
Common Typos
- 6V7RE20
- 6V7RE2O
- 6V7REZ0
- 6V7REZO
- GV7RE2O
- GV7REZ0
- GV7REZO
Appended Numbers
- GV7RE20-A
- GV7RE20-B
- GV7RE20-C
- GV7RE20-D
- GV7RE20-E
- GV7RE20-F
- GV7RE20-G
- GV7RE20-H
- GV7RE20-I
- GV7RE20-J
- GV7RE20-K
- GV7RE20-L
- GV7RE20-M
- GV7RE20-N
- GV7RE20-O
- GV7RE20-P
- GV7RE20-Q
- GV7RE20-R
- GV7RE20-S
- GV7RE20-T
- GV7RE20-U
- GV7RE20-V
- GV7RE20-W
- GV7RE20-X
- GV7RE20-Y
- GV7RE20-Z
More Products Like This
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier