- Description: LIMIT SWITCH 600 VDC 10 AMP XC2J +OPTIONS
- Product weight: 1.33 lb(US) (0.605 kg)
- Range of product: OsiSense XC
- IP degree of protection: IP65 conforming to IEC 60529, IP657 conforming to NF C 20-010
- Standards: IEC 60337-1, CSA C22.2 No 14, UL 508, EN/IEC 60947-5-1, VDE 0660-200
- Device short name: XC2J
- Width: 1.57 in (40 mm)
- Height: 5.55 in (141 mm)
- Depth: 2.56 in (65 mm)
- Protective treatment: TC
- [Ui] rated insulation voltage: 300 V conforming to CSA C22.2 No 14, 500 V conforming to IEC 60947-5-1, 500 V conforming to NF C 20-040 group C
- Mechanical durability: 30000000 cycles
- Shock resistance: 25 gn 18 ms conforming to IEC 60068-2-27
- Vibration resistance: 10 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
- Electrical durability: 5000000 cycles DC-13, 120 V 4 W, <= 3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 5000000 cycles DC-13, 24 V 10 W, <= 3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 5000000 cycles DC-13, 48 V 7 W, <= 3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
- Electrical connection: Screw-clamp terminals, 1 x 0.5...2 x 2.5 mm
- Material: Metal
- Number of poles: 1
- Head type: Rotary head
- Fixing mode: By the body
- Series name: Special format
- Product or component type: Limit switch
- Cable entry: 1 entry incorporating cable gland, cable outer diameter: 0.24...0.53 in (6...13.5 mm)
- Product specific application: For severe applications
- Contacts insulation form: Za
- IK degree of protection: IK08
- Contacts material: Silver plated contacts
- Electrical shock protection class: Class I conforming to IEC 60536, Class I conforming to NF C 20-030
- Body type: Fixed
- Positive opening: Without
- Ambient air temperature for operation: -13...158 F (-25...70 C)
- Minimum actuation speed: 0.001 m/min
- Ambient air temperature for storage: -40...158 F (-40...70 C)
- Contact code designation: DC-13 Q300(Ue = 250 V, Ie = 0.27 A) EN/IEC 60947-5-1, AC-15 A300(Ue = 240 V, Ie = 3 A) Ithe = 10 A EN/IEC 60947-5-1
- Movement of operating head: Rotary
- Product certifications: NEMKO, DEMKO, CSA
- Type of operator: Thermoplastic roller lever
- Resistance across terminals: <= 25 MOhm conforming to IEC 60255-7 category 3, <= 25 MOhm conforming to NF C 93-050 method A
- Switch actuation: By 30 cam
- Short-circuit protection: 10 A by cartridge fuse, type gG
- Type of approach: Lateral approach, 2 directions
- Contact operation: Snap action
- Minimum torque for tripping: 2.65 lbf.in (0.3 N.m)
- Maximum actuation speed: 4.92 ft/s (1.5 m/s)
- terminals description ISO n1: (13-14-11-12)OF
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on XC2JC101 . Santa Clara Systems carries 10,327 items from Telemecanique.
- Limit Switch 600 Vdc 10 Amp Xc2j +options
Alternates
Common Typos
- XC2JC10I
- XC2JC10L
- XC2JC1O1
- XC2JC1OI
- XC2JC1OL
- XC2JCI01
- XC2JCI0I
- XC2JCI0L
- XC2JCIO1
- XC2JCIOI
- XC2JCIOL
- XC2JCL01
- XC2JCL0I
- XC2JCL0L
- XC2JCLO1
- XC2JCLOI
- XC2JCLOL
- XCZJC101
- XCZJC10I
- XCZJC10L
- XCZJC1O1
- XCZJC1OI
- XCZJC1OL
- XCZJCI01
- XCZJCI0I
- XCZJCI0L
Appended Numbers
- XC2JC101-A
- XC2JC101-B
- XC2JC101-C
- XC2JC101-D
- XC2JC101-E
- XC2JC101-F
- XC2JC101-G
- XC2JC101-H
- XC2JC101-I
- XC2JC101-J
- XC2JC101-K
- XC2JC101-L
- XC2JC101-M
- XC2JC101-N
- XC2JC101-O
- XC2JC101-P
- XC2JC101-Q
- XC2JC101-R
- XC2JC101-S
- XC2JC101-T
- XC2JC101-U
- XC2JC101-V
- XC2JC101-W
- XC2JC101-X
- XC2JC101-Y
- XC2JC101-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier