- Description: limit switch XC1AC - reinforced roller lever - 1C/O
- Product weight: 1.31 lb(US) (0.595 kg)
- Range of product: OsiSense XC
- IP degree of protection: IP65 IEC 60529, IP65 NF C 20-010
- Standards: EN 60947-5-1, IEC 60947-5-1, VDE 0660-200, CSA C22.2 No 14, IEC 60337-1
- Device short name: XC1AC
- Width: 3.03 in (77 mm)
- Height: 5.47 in (139 mm)
- Depth: 1.73 in (44 mm)
- Protective treatment: TC
- [Ui] rated insulation voltage: 600 V AC CSA C22.2 No 14, 600 V DC CSA C22.2 No 14, 500 V AC IEC 60947-5-1, 500 V AC NF C 20-040, 600 V DC IEC 60947-5-1, 600 V DC NF C 20-040
- Mechanical durability: 10000000 cycles
- Shock resistance: 95 gn 11 ms IEC 60068-2-27
- Vibration resistance: 9 gn 10...500 Hz IEC 60068-2-6
- Electrical durability: 1000000 cycles AC-15, 110 V 900 VA, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 50/60 Hz, inductive load type, 1000000 cycles AC-15, 230 V 1900 VA, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 50/60 Hz, inductive load type, 1000000 cycles AC-15, 48 V 450 VA, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 50/60 Hz, inductive load type, 1000000 cycles DC-13, 110 V 100 W, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C inductive load type, 1000000 cycles DC-13, 230 V 95 W, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C inductive load type, 1000000 cycles DC-13, 48 V 100 W, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C inductive load type, 3000000 cycles AC-15, 110 V 350 VA, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 50/60 Hz, inductive load type, 3000000 cycles AC-15, 230 V 430 VA, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 50/60 Hz, inductive load type, 3000000 cycles AC-15, 48 V 170 VA, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 50/60 Hz, inductive load type, 3000000 cycles DC-13, 110 V 40 W, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C inductive load type, 3000000 cycles DC-13, 230 V 33 W, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C inductive load type, 3000000 cycles DC-13, 48 V 35 W, <= 60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C inductive load type
- Electrical connection: Screw-clamp terminals, 1 x 0.5...1 x 2.5 mm
- Material: Metal
- Number of poles: 1
- Head type: Plunger head
- Contacts insulation form: Za
- Series name: Special format
- Maximum actuation speed: 3.28 ft/s (1 m/s) from left, 1.64 ft/s (0.5 m/s) from right
- Product or component type: Limit switch
- [Ithe] conventional enclosed thermal current: 10:00 AM
- Product specific application: Materials handling
- Electrical shock protection class: Class I conforming to IEC 61140, Class I conforming to NF C 20-030
- Resistance across terminals: <= 8 mOhm
- Ambient air temperature for operation: -13...158 F (-25...70 C)
- Sensor design: -
- Short-circuit protection: 10 A cartridge fuse gG
- Ambient air temperature for storage: -40...158 F (-40...70 C)
- Body type: Fixed
- Operating position: Any position
- Product certifications: CSA
- Fixing mode: By the body
- Movement of operating head: Linear
- Type of operator: Spring return roller lever metal reinforced
- Switch actuation: By 30 cam
- terminals description ISO n1: (11-12)NC, (13-14)NO
- Type of approach: Lateral approach 2 directions
- Cable entry: 3 entries tapped for Pg 13.5 cable gland, cable outer diameter: 0.35...0.47 in (9...12 mm)
- Contacts type and composition: 1 C/O
- Contact operation: Slow-break
- Number of steps: 1
- Positive opening: Without
- Minimum force for tripping: 29 N
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on XC1AC117 . Santa Clara Systems carries 10,327 items from Telemecanique.
- Limit Switch Xc1ac - Reinforced Roller Lever - 1c/o
Alternates
Common Typos
- XC1AC1I7
- XC1AC1L7
- XC1ACI17
- XC1ACII7
- XC1ACIL7
- XC1ACL17
- XC1ACLI7
- XC1ACLL7
- XCIAC117
- XCIAC1I7
- XCIAC1L7
- XCIACI17
- XCIACII7
- XCIACIL7
- XCIACL17
- XCIACLI7
- XCIACLL7
- XCLAC117
- XCLAC1I7
- XCLAC1L7
- XCLACI17
- XCLACII7
- XCLACIL7
- XCLACL17
- XCLACLI7
- XCLACLL7
Appended Numbers
- XC1AC117-A
- XC1AC117-B
- XC1AC117-C
- XC1AC117-D
- XC1AC117-E
- XC1AC117-F
- XC1AC117-G
- XC1AC117-H
- XC1AC117-I
- XC1AC117-J
- XC1AC117-K
- XC1AC117-L
- XC1AC117-M
- XC1AC117-N
- XC1AC117-O
- XC1AC117-P
- XC1AC117-Q
- XC1AC117-R
- XC1AC117-S
- XC1AC117-T
- XC1AC117-U
- XC1AC117-V
- XC1AC117-W
- XC1AC117-X
- XC1AC117-Y
- XC1AC117-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier