- Description: pump control relay RM35-BA - range 1..10 A
- Range of product: Zelio Control
- IP degree of protection: IP20(terminals) conforming to IEC 60529, IP30 (casing) conforming to IEC 60529
- Standards: EN/IEC 60255-6
- Width: 1.38 in (35 mm)
- [Ui] rated insulation voltage: 400 V conforming to IEC 60664-1
- Mechanical durability: 30000000 cycles
- Tightening torque: 5.31...8.85 lbf.in (0.6...1 N.m) conforming to IEC 60947-1
- Connections - terminals: Screw terminals 1 x 0.5...1 x 4 mm - AWG 20...AWG 11, solid cable without cable end, Screw terminals 2 x 0.5...2 x 2.5 mm - AWG 20...AWG 14, solid cable without cable end, Screw terminals 1 x 0.2...1 x 2.5 mm - AWG 24...AWG 12, flexible cable with cable end, Screw terminals 2 x 0.2...2 x 1.5 mm - AWG 24...AWG 16, flexible cable with cable end
- Mounting support: 35 mm symmetrical DIN rail conforming to EN/IEC 60715
- Operating rate: <= 360 operations/hour under full load
- Vibration resistance: 0.35 mm (f = 5...57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1, 1 gn (f = 57.6...150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1
- Shock resistance: 15 gn 11 ms conforming to IEC 60255-21-1
- Electrical durability: 100000 cycles
- Insulation resistance: > 500 MOhm at 500 V DC between supply and relay output conforming to 60255-5, > 500 MOhm at 500 V DC between measurement and relay output conforming to 60664-1, > 1 MOhm at 500 V DC between supply and measurement conforming to 60255-5, > 500 MOhm at 500 V DC between supply and relay output conforming to 60664-1, > 500 MOhm at 500 V DC between measurement and relay output conforming to 60255-5, > 1 MOhm at 500 V DC between supply and measurement conforming to 60664-1
- Utilization category: AC-12 conforming to IEC 60947-5-1, AC-13 conforming to IEC 60947-5-1, AC-14 conforming to IEC 60947-5-1, AC-15 conforming to IEC 60947-5-1, DC-12 conforming to IEC 60947-5-1, DC-13 conforming to IEC 60947-5-1
- Control circuit voltage limits: - 15 % + 10 % Un
- [Us] rated supply voltage: 208...480 V AC 3 phases, 230 V AC 1 phase
- Overvoltage category: III conforming to IEC 60664-1
- Relative humidity: 95 % at 131 F (55 C) conforming to IEC 60068-2-30
- Response time: < 300 ms in the event of a fault
- Housing material: Self-extinguishing plastic
- Reset time: 2000 ms
- Immunity to micro breaks: 500 ms
- Product or component type: Modular measurement and control relays
- Maximum switching voltage: 250 V AC/DC
- Electromagnetic compatibility: Emission standard for industrial environments conforming to EN/IEC 61000-6-4, Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3, Immunity for industrial environments conforming to NF EN/IEC 61000-6-2
- Relay type: Pump control relays
- Product specific application: For 3-phase and single-phase pump
- Product certifications: GL, GOST, C-Tick, UL, CSA
- Relay name: RM35BA
- Supply voltage limits: 183...528 V AC
- Ambient air temperature for storage: -40...158 F (-40...70 C)
- Relay monitored parameters: Phase sequence on 3-phase supply, Phase failure on 3-phase supply, Overcurrent and undercurrent control
- Ambient air temperature for operation: -4...122 F (-20...50 C)
- Time delay: Reset on terminal Y2 fixed 0.3 s, Ti on energisation adjustable 1...60 s, +/- 10 %, Tt on crossing the threshold adjustable 0.1...10 s, +/- 10 %
- Resistance across terminals: 0.01 Ohm E1-L2 terminals
- switching capacity in VA: 1250 VA
- Minimum switching current: 10 mA at 5 V DC
- Output contacts: 1 C/O
- Maximum switching current: 5 A AC/DC
- Nominal output current: 5:00 AM
- power consumption in VA: <= 5 VA AC
- Measuring cycle: <= 140 ms as true rms value
- Pollution degree: 3 conforming to IEC 60664-1
- Measurement range: 1...10 A AC
- Run-up delay at power-up: 0.5 s
- Dielectric strength: 2 kV AC 50 Hz (shock wave 4 kV)
- Hysteresis: 5 % of threshold
- Measurement accuracy: +/- 10 % of the full scale value
- Repeat accuracy: +/- 1 % input and measurement circuit, +/- 1 % time delay
- Measurement error: 1 % by volt over the whole range, +/- 0.05 %/C
- Input current: 11 A permanent at 25 C E1-L2 terminals, 50 A non repetitive < 1 s at 25 C E1-L2 terminals
- Marking: CE : EMC 89/336/EEC, CE : 73/23/EEC
- Supply frequency: 50/60 Hz +/- 10 %
- Operating position: Any position
- status LED: 1 LED green power ON, 1 LED yellow fault, 1 LED yellow relay ON
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on RM35BA10 . Santa Clara Systems carries 10,327 items from Telemecanique.
- Pump Control Relay Rm35-Ba - Range 1..10 A
Alternates
Common Typos
- RM358A10
- RM358A1O
- RM358AI0
- RM358AIO
- RM358AL0
- RM358ALO
- RM35BA1O
- RM35BAI0
- RM35BAIO
- RM35BAL0
- RM35BALO
- RM3S8A10
- RM3S8A1O
- RM3S8AI0
- RM3S8AIO
- RM3S8AL0
- RM3S8ALO
- RM3SBA10
- RM3SBA1O
- RM3SBAI0
- RM3SBAIO
- RM3SBAL0
- RM3SBALO
Appended Numbers
- RM35BA10-A
- RM35BA10-B
- RM35BA10-C
- RM35BA10-D
- RM35BA10-E
- RM35BA10-F
- RM35BA10-G
- RM35BA10-H
- RM35BA10-I
- RM35BA10-J
- RM35BA10-K
- RM35BA10-L
- RM35BA10-M
- RM35BA10-N
- RM35BA10-O
- RM35BA10-P
- RM35BA10-Q
- RM35BA10-R
- RM35BA10-S
- RM35BA10-T
- RM35BA10-U
- RM35BA10-V
- RM35BA10-W
- RM35BA10-X
- RM35BA10-Y
- RM35BA10-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier