- Description: Reversing Contactor
- Range of product: TeSys D
- IP degree of protection: IP2x conforming to IEC 60529
- Standards: CSA C22.2 No 14
- Device short name: LC2D
- Width: 165 mm
- Height: 132 mm
- Depth: 142 mm
- Protective treatment: TH (pollution degree 3) conforming to IEC 60068
- [Ui] rated insulation voltage: Control circuit: 600 V CSA certified
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947
- Operating altitude: 3000 m without
- Mechanical durability: 6000000 cycles
- Tightening torque: Control circuit: 1.7 N.m - cable 12.5 mm - with screwdriver flat 6 mm
- Connections - terminals: Control circuit: 1 cable(s) 14 mmflexible with cable end
- Mounting support: Rail
- [Ith] conventional free air thermal current: 10 A (at 60 C) for control circuit
- [Uc] control circuit voltage: 120 V AC 60 Hz
- Shock resistance: 10 gn contactor closed
- Vibration resistance: 2 gn 5300 Hz contactor opened
- Insulation resistance: > 10 MOhm for control circuit
- motor power kW: 11 kW at 220...240 V AC 50/60 Hz
- [Ie] rated operational current: Power circuit: 40 A AC AC-3 (at <60 C)
- Control circuit voltage limits: Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60 C)
- Poles description: 3P
- Overvoltage category: III
- Operating time: 12...26 ms closing
- Associated fuse rating: 10 A gG for control circuit conforming to IEC 60947-5-1
- Control circuit type: AC
- Product or component type: Reversing contactor
- Contactor application: Motor control
- Utilisation category: AC-4
- Coil type: Standard
- Pole contact composition: 3 NO
- Assembly style: Ready assembled
- Coil technology: Without built-in bidirectional peak limiting diode suppressor
- Protective cover: With
- Auxiliary contacts type: type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
- Auxiliary contact composition: 1 NO + 1 NC
- Interlocking type: Mechanical
- Flame retardance: V1 conforming to UL 94
- [Ue] rated operational voltage: Power circuit: <= 1000 V AC 25...400 Hz
- Irms rated making capacity: 140 A AC for control circuit conforming to IEC 60947-5-1
- Rated breaking capacity: 800 A at 440 V for power circuit conforming to IEC 60947
- Average impedance: - Ith 60 A 50 Hz for power circuit
- Power dissipation per pole: 2.4 W AC-3 - Ith 60 A
- inrush power in VA: 200 VA cos phi 0.75 (at 20 C)
- hold-in power consumption in VA: 20 VA 50 Hz cos phi 0.3 (at 20 C)
- Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
- Maximum operating rate: 3600 cyc/h 60 C
- Minimum switching current: 5 mA for control circuit
- Minimum switching voltage: 17 V for control circuit
- Non-overlap time: 1.5 ms on de-energisation between NC and NO contacts
- Net weight: 2.4 kg
- Ambient air temperature for operation: -560 C
- Ambient air temperature for storage: -6080 C
- Permissible ambient air temperature around the device: -4070 C at Uc
- Fire resistance: 850 C conforming to IEC 60695-2-1
- Heat dissipation: 610 W at 60 Hz for control circuit
- Circularity Profile: End of Life Information
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC2D40G6 . Santa Clara Systems carries 10,326 items from Telemecanique.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.
Alternates
Common Typos
- 1C2D4066
- 1C2D406G
- 1C2D40G6
- 1C2D40GG
- 1C2D4O66
- 1C2D4O6G
- 1C2D4OG6
- 1C2D4OGG
- 1CZD4066
- 1CZD40G6
- 1CZD40GG
- LC2D4066
- LC2D406G
- LC2D40GG
- LC2D4O66
- LC2D4O6G
- LC2D4OG6
- LC2D4OGG
- LCZD4066
- LCZD406G
- LCZD40G6
- LCZD40GG
- LCZD4O66
- LCZD4O6G
- LCZD4OG6
- LCZD4OGG
Appended Numbers
- LC2D40G6-A
- LC2D40G6-B
- LC2D40G6-C
- LC2D40G6-D
- LC2D40G6-E
- LC2D40G6-F
- LC2D40G6-G
- LC2D40G6-H
- LC2D40G6-I
- LC2D40G6-J
- LC2D40G6-K
- LC2D40G6-L
- LC2D40G6-M
- LC2D40G6-N
- LC2D40G6-O
- LC2D40G6-P
- LC2D40G6-Q
- LC2D40G6-R
- LC2D40G6-S
- LC2D40G6-T
- LC2D40G6-U
- LC2D40G6-V
- LC2D40G6-W
- LC2D40G6-X
- LC2D40G6-Y
- LC2D40G6-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier