- Description: Multipurpose Digital Contact Sensor
- Weight: Approx 110 g (including Power cable)
- Footnotes: *1 The amplifier models indicated with ?A? at the end of the model code are the upgraded version that provides compatibility with the DL series communication unit. Other models (without ?A? at the end of the model code) are not compatible with the DL series, but compatible with GT-H10/H10L/H22/H22L. *2 Be sure to mount the DIN rail mounting amplifier on a DIN rail (i.e. the unit should be mounted on the metal DIN plate itself). For additional amplifier unit installation, be sure to use the end unit (OP-26751). *3 One main unit and nine expansion units (ten in total) can be additionally installed. For additional amplifier unit installation, each output current must be 20 mA or less. *4 If additional amplifier units are installed, the power supply voltage is 24 VDC.
- Response time: hsp (1.5 ms) , 5 ms, 10 ms, 100 ms, 500 ms, 1 s, 5 s
- Output: NPN output
- Material: Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: Polycarbonate, Cable: PVC
- Accessories: Instruction manual
- Mounting method: DIN rail mount*2
- Main unit/Expansion unit: Main unit*3
- Current consumption. - At 12 V - Normal: 1140 mW (95 mA) or less
- Current consumption. - At 12 V - Power saving (Eco): 600 mW (50 mA) or less
- Current consumption. - At 24 V - Normal: 1200 mW (50 mA) or less
- Current consumption. - At 24 V - Power saving (Eco): 840 mW (35 mA) or less
- Display power - Measured value display: 6-digit 7-segment LED (red)
- Display method - Other displays: 2-color, 13-level bar LED display (red, green), indicators (red, green)
- Display range: -99.999 to 999.999
- Display resolution: 1 ?m 0.039 Mil
- Sampling rate: 2000 times/second
- Major functions: Preset, Hold, Variable hysteresis, Variable response time, Multiplier setting, Bank function (4 banks), Self-timing, Power save (eco) mode, Application mode, Calibration function, Core alarm
- Control input - Timing input: Input time: 2 ms or more
- Control input - Preset input: Input time: 20 ms or more
- Control input - Bank input: Input time: 20 ms or more
- HIGH, GO, LOW output: NPN open collector, 50 mA max. 40 V or less residual voltage: 1 V or less, N.O./N.C. switchable
- Rating - Power source voltage: 12 to 24 VDC, ripple (P-P) 10% or less*4
- Environmental resistance - Operating temperature range: -10 to 55C 14 to 131F, No freezing
- Environmental resistance - Operating ambient humidity: 35 to 85% RH (No condensation)
- Environmental resistance - Vibration: 10 to 55 Hz, double amplitude: 1.5 mm 0.06", 2 hours in each of X, Y, and Z directions
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on GT-71A . Santa Clara Systems carries 2,107 items from Keyence.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.
Alternates
Common Typos
- 6T-71A
- 6T-7IA
- 6T-7LA
- GT-7IA
- GT-7LA
Appended Numbers
- GT-71A-A
- GT-71A-B
- GT-71A-C
- GT-71A-D
- GT-71A-E
- GT-71A-F
- GT-71A-G
- GT-71A-H
- GT-71A-I
- GT-71A-J
- GT-71A-K
- GT-71A-L
- GT-71A-M
- GT-71A-N
- GT-71A-O
- GT-71A-P
- GT-71A-Q
- GT-71A-R
- GT-71A-S
- GT-71A-T
- GT-71A-U
- GT-71A-V
- GT-71A-W
- GT-71A-X
- GT-71A-Y
- GT-71A-Z