• Telemecanique RE17RLMU Barcode

RE17RLMU

Let Us Find It

Current response time:

By 5AM PT on Monday
  • Description: asymmetrical flashing relay - 1 s..100 h - 24..240 V AC - 1 OC
  • Product weight: 0.15 lb(US) (0.07 kg)
  • Range of product: Zelio Time
  • IP degree of protection: IP20 (terminal block) conforming to IEC 60529, IP40 (housing) conforming to IEC 60529, IP50 (front panel) conforming to IEC 60529
  • Standards: EN 61000-6-4, EN 61000-6-1, 2004/108/EC, IEC 61812-1, EN 61000-6-3, 2006/95/EC, EN 61000-6-2
  • Device short name: RE17R
  • Width: 0.69 in (17.5 mm)
  • [Uimp] rated impulse withstand voltage: 5 kV (1.2/50 s)
  • Mechanical durability: 10000000 cycles
  • Tightening torque: 5.31...8.85 lbf.in (0.6...1 N.m) conforming to IEC 60947-1
  • Connections - terminals: Screw terminals, clamping capacity: 1 x 0.5...1 x 3.3 mm AWG 20...AWG 12 (solid) without cable end, Screw terminals, clamping capacity: 2 x 0.5...2 x 2.5 mm AWG 20...AWG 14 (solid) without cable end, Screw terminals, clamping capacity: 1 x 0.2...1 x 2.5 mm AWG 24...AWG 14 (flexible) with cable end, Screw terminals, clamping capacity: 2 x 0.2...2 x 1.5 mm AWG 24...AWG 16 (flexible) with cable end
  • Mounting support: 35 mm DIN rail conforming to EN/IEC 60715
  • Vibration resistance: 20 m/s (f = 10...150 Hz) conforming to IEC 60068-2-6
  • Shock resistance: 15 gn (duration = 11 ms) conforming to IEC 60068-2-27
  • Electrical durability: 100000 cycles resistive load (8 A at 250 V AC maximum)
  • Insulation resistance: 100 MOhm at 500 V DC conforming to IEC 60664-1
  • [Us] rated supply voltage: 24...240 V AC at 50/60 Hz, 24 V DC
  • Relative humidity: 93 % without condensation conforming to IEC 60068-2-30
  • Control type: Selector switch on front panel
  • Breaking capacity: <= 2000 VA
  • Mounting position: Any position in relation to normal vertical mounting plane
  • Input voltage: 10 V
  • Housing material: Self-extinguishing
  • Contacts type and composition: 1 C/O
  • Immunity to micro breaks: <= 20 ms
  • Product or component type: Modular timing relay
  • Contacts material: Cadmium free
  • Discrete output type: Relay
  • Product certifications: cULus, CSA, GL
  • Ambient air temperature for storage: -22...140 F (-30...60 C)
  • Voltage range: 0.85...1.1 Us
  • Ambient air temperature for operation: -4...140 F (-20...60 C)
  • Time delay type: L, Li
  • Supply frequency: 50...60 Hz (+/- 5 %)
  • Time delay range: 1...10 min, 10...100 h, 1...10 h, 6...60 s, 6...60 min, 1...10 s, 0.1...1 s
  • Nominal output current: 8:00 AM
  • Electromagnetic compatibility: Electrostatic discharge immunity test, in contact at 6 kV conforming to IEC 61000-4-2 level 3, Electrostatic discharge immunity test, in air at 8 kV conforming to IEC 61000-4-2 level 3, Susceptibility to electromagnetic fields, 80 MHz to 1 GHz at 10 V/m conforming to IEC 61000-4-3 level 3, Electrical fast transient/burst immunity test, capacitive connecting clip at 1 kV conforming to IEC 61000-4-4 level 3, Electrical fast transient/burst immunity test, direct at 2 kV conforming to IEC 61000-4-4 level 3, 1.2/50 s shock waves immunity test, differential mode at 1 kV conforming to IEC 61000-4-5 level 3, 1.2/50 s shock waves immunity test, common mode at 2 kV conforming to IEC 61000-4-5 level 3, Conducted RF disturbances, 0.15...80 MHz at 10 V conforming to IEC 61000-4-6 level 3, Voltage dips and interruptions immunity test, 1 cycle at 0 % conforming to IEC 61000-4-11, Voltage dips and interruptions immunity test, 25/30 cycles at 70 % conforming to IEC 61000-4-11, Conducted and radiated emissions conforming to EN 55022 class B
  • Repeat accuracy: +/- 0.5 % conforming to IEC 61812-1
  • Temperature drift: +/- 0.05 %/C
  • Voltage drift: +/- 0.2 %/V
  • Setting accuracy of time delay: +/- 10 % of full scale at 25 C conforming to IEC 61812-1
  • Impulse duration: 100 ms with load in parallel typical, 30 ms typical
  • Reset time: 120 ms on de-energisation typical
  • On-load factor: 100%
  • power consumption in VA: 0...32 VA at 240 V AC
  • power consumption in W: <= 0.6 W at 24 V DC
  • Minimum switching current: 10 mA at 5 V DC
  • Maximum switching current: 8 A AC/DC
  • Maximum switching voltage: 250 V AC
  • operating rate in Hz: 10 Hz
  • Dielectric strength: 2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
  • Delay response: < 100 ms
  • Marking: CE
  • Creepage distance: 4 kV/3 conforming to IEC 60664-1
  • Safety reliability data: B10d = 270000, MTTFd = 296.8 years
  • Local signaling: LED indicator on steady: relay energized, no timing in progress, LED indicator flashing: timing in progress (80 % ON and 20 % OFF)
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on RE17RLMU . Santa Clara Systems carries 10,327 items from Telemecanique.
  • Asymmetrical Flashing Relay - 1 S..100 H - 24..240 V Ac - 1 Oc

Alternates

    Common Typos

    • RE17R1MU
    • RE17RIMU
    • REI7R1MU
    • REI7RIMU
    • REI7RLMU
    • REL7R1MU
    • REL7RIMU
    • REL7RLMU

    Appended Numbers

    • RE17RLMU-A
    • RE17RLMU-B
    • RE17RLMU-C
    • RE17RLMU-D
    • RE17RLMU-E
    • RE17RLMU-F
    • RE17RLMU-G
    • RE17RLMU-H
    • RE17RLMU-I
    • RE17RLMU-J
    • RE17RLMU-K
    • RE17RLMU-L
    • RE17RLMU-M
    • RE17RLMU-N
    • RE17RLMU-O
    • RE17RLMU-P
    • RE17RLMU-Q
    • RE17RLMU-R
    • RE17RLMU-S
    • RE17RLMU-T
    • RE17RLMU-U
    • RE17RLMU-V
    • RE17RLMU-W
    • RE17RLMU-X
    • RE17RLMU-Y
    • RE17RLMU-Z

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo