- Description: TeSys GV2 - Circuit breaker - magnetic - 32 A - screw clamp terminals
- Product weight: 0.73 lb(US) (0.33 kg)
- Standards: NF C 63-120, NF C 63-650, IEC 60947-1, VDE 0113, VDE 0660, IEC 60947-2, EN 60204, NF C 79-130
- Device short name: GV2LE
- Width: 1.77 in (45 mm)
- Height: 3.5 in (89 mm)
- Depth: 3.09 in (78.5 mm)
- Protective treatment: TH
- [Ui] rated insulation voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2
- Operating altitude: 6561.68 ft. (2000 m)
- Mechanical durability: 100000 cycles
- Tightening torque: 1.7 N.m on screw clamp terminals
- Connections - terminals: Screw clamp terminals 2 cable(s) 0...0.01 in (1...6 mm) - cable stiffness : solid, Screw clamp terminals 2 cable(s) 0...0.01 in (1.5...6 mm) - cable stiffness : flexible - without cable end, Screw clamp terminals 2 cable(s) 0...0.01 in (1...4 mm) - cable stiffness : flexible - with cable end
- Range: TeSys
- Mounting support: Rail, Plate
- System Voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
- Operating rate: 40 cyc/h
- Product name: TeSys GV2
- Electrical durability: 100000 cycles AC-3 at 415 V
- motor power kW: 15 kW at 400/415 V AC 50/60 Hz, 22 kW at 690 V AC 50/60 Hz, 18.5 kW at 500 V AC 50/60 Hz
- Utilization category: AC-3 conforming to IEC 60947-4-1, Category A conforming to IEC 60947-2
- Poles description: 3P
- Control type: Rocker lever
- Breaking capacity: 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 6 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 4 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2, 10 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
- Mounting position: Vertical, Horizontal
- Mounting mode: By Clips / By Screws
- Product certifications: CCC, CSA
- Product or component type: Circuit breaker
- IK degree of protection: IK04
- Device application: Motor
- Ambient air temperature for operation: -4...140 F (-20...60 C)
- Ambient air temperature for storage: -40...176 F (-40...80 C)
- Network type: AC
- Fire resistance: 1760 F (960 C) conforming to IEC 60695-2-1
- Network frequency: 50/60 Hz conforming to IEC 60947-2
- Power dissipation per pole: 1.8 W
- [Ics] rated service short-circuit breaking capacity: 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 50 %at 440 V AC 50/60 Hz conforming to IEC 60947-2, 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2, 75 %at 690 V AC 50/60 Hz conforming to IEC 60947-2
- Trip unit rating: 32 A
- Trip unit technology: Magnetic
- Rated duty: Continuous conforming to IEC 60947-4-1
- Magnetic tripping current: 416 A
- Mechanical robustness: Shocks 30 Gn conforming to IEC 60068-2-27, Vibrations 5 Gn, 5...150 Hz conforming to IEC 60068-2-6
- Suitability for isolation: Yes conforming to IEC 60947-1
- Phase failure sensitivity: Yes
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on GV2LE32 . Santa Clara Systems carries 10,400 items from Telemecanique.
- Tesys Gv2 - Circuit Breaker - Magnetic - 32 A - Screw Clamp Terminals
Alternates
Common Typos
- 6V21E32
- 6V21E3Z
- 6V2IE32
- 6V2IE3Z
- 6V2LE32
- 6V2LE3Z
- 6VZ1E32
- 6VZ1E3Z
- 6VZIE32
- 6VZIE3Z
- 6VZLE32
- 6VZLE3Z
- GV21E32
- GV21E3Z
- GV2IE32
- GV2IE3Z
- GV2LE3Z
- GVZ1E32
- GVZ1E3Z
- GVZIE32
- GVZIE3Z
- GVZLE32
- GVZLE3Z
Appended Numbers
- GV2LE32-A
- GV2LE32-B
- GV2LE32-C
- GV2LE32-D
- GV2LE32-E
- GV2LE32-F
- GV2LE32-G
- GV2LE32-H
- GV2LE32-I
- GV2LE32-J
- GV2LE32-K
- GV2LE32-L
- GV2LE32-M
- GV2LE32-N
- GV2LE32-O
- GV2LE32-P
- GV2LE32-Q
- GV2LE32-R
- GV2LE32-S
- GV2LE32-T
- GV2LE32-U
- GV2LE32-V
- GV2LE32-W
- GV2LE32-X
- GV2LE32-Y
- GV2LE32-Z
More Products Like This
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier