- Description: On-delay Timing Relay - 0.05s?300h - 24?240V AC/DC - 1C/O
- Product weight: 0.22 lb(US) (0.1 kg)
- Range of product: Zelio Time
- IP degree of protection: IP20(terminals) conforming to IEC 60529, IP40 (housing) conforming to IEC 60529, IP50 (front face) conforming to IEC 60529
- Standards: UL 508, IEC 61812-1
- Device short name: RE22
- Width: 0.89 in (22.5 mm)
- [Uimp] rated impulse withstand voltage: 5 kV 1.2...50 s conforming to IEC 60664-1
- Mechanical durability: 10000000 cycles
- Tightening torque: 5.31...8.85 lbf.in (0.6...1 N.m) conforming to IEC 60947-1
- Connections - terminals: Screw terminals : 1 x 0.5...1 x 3.3 mm, AWG 20...AWG 12 solid cable without cable end, Screw terminals : 2 x 0.5...2 x 2.5 mm, AWG 20...AWG 14 solid cable without cable end, Screw terminals : 1 x 0.2...1 x 2.5 mm, AWG 24...AWG 14 flexible cable with cable end, Screw terminals : 2 x 0.2...2 x 1.5 mm, AWG 24...AWG 16 flexible cable with cable end
- Mounting support: 35 mm DIN rail conforming to EN/IEC 60715
- Vibration resistance: 20 m/s (f = 10...150 Hz) conforming to IEC 60068-2-6
- Shock resistance: 15 gn (not operating) (duration = 11 ms) conforming to IEC 60068-2-27, 5 gn (in operation) (duration = 11 ms) conforming to IEC 60068-2-27
- Electrical durability: 100000 cycles for 8 A at 250 V AC-1, 100000 cycles for 2 A at 24 V DC-1
- Insulation resistance: 100 MOhm at 500 V DC conforming to IEC 60664-1
- [Us] rated supply voltage: 24...240 V AC/DC at 50/60 Hz
- Overvoltage category: III conforming to IEC 60664-1
- Relative humidity: 95 % at 25...55 C
- Control type: Rotary knob, Diagnostic button
- Mounting position: Any position
- Input voltage: <= 2.4 V
- Housing material: Self-extinguishing
- Contacts type and composition: 1 C/O timed contact, cadmium free
- Dielectric strength: 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 61812-1
- Product or component type: Modular timing relay
- Time delay type: Aw, A
- Discrete output type: Relay
- Time delay range: 30...300 s, 10...100 s, 0.3...3 s, 1...10 s, 3...30 s, 3...30 min, 30...300 h, 0.05...1 s, 30...300 min, 3...30 h
- Directives: 2004/108/EC - electromagnetic compatibility, 2006/95/EC - low voltage directive
- Product certifications: UL, CSA, CE, GL, EAC, RCM, China RoHS, CCC
- Nominal output current: 8:00 AM
- Ambient air temperature for operation: -4...140 F (-20...60 C)
- Ambient air temperature for storage: -40...158 F (-40...70 C)
- Voltage range: 0.85...1.1 Us
- Supply frequency: 50...60 Hz (+/- 5 %)
- Pollution degree: 3 conforming to IEC 60664-1
- Repeat accuracy: +/- 0.5 % conforming to IEC 61812-1
- Electromagnetic compatibility: Fast transients immunity test (test level: 1 kV, level 3 - capacitive connecting clip) conforming to IEC 61000-4-4, Surge immunity test (test level: 1 kV, level 3 - differential mode) conforming to IEC 61000-4-5, Surge immunity test (test level: 2 kV, level 3 - common mode) conforming to IEC 61000-4-5, Electrostatic discharge (test level: 6 kV, level 3 - contact discharge) conforming to IEC 61000-4-2, Electrostatic discharge (test level: 8 kV, level 3 - air discharge) conforming to IEC 61000-4-2, Radiated radio-frequency electromagnetic field immunity test (test level: 10 V/m, level 3 - 80 MHz...1 GHz) conforming to IEC 61000-4-3, Conducted RF disturbances (test level: 10 V, level 3 - 0.15...80 MHz) conforming to IEC 61000-4-6, Fast transient bursts (test level: 2 kV, level 3 - direct contact) conforming to IEC 61000-4-4, Immunity to micro breaks and voltage drops (test level: 30 % - 500 ms) conforming to IEC 61000-4-11, Immunity to micro breaks and voltage drops (test level: 100 % - 20 ms) conforming to IEC 61000-4-11
- Temperature drift: +/- 0.05 %/C
- Voltage drift: +/- 0.2 %/V
- Setting accuracy of time delay: +/- 10 % of full scale at 25 C conforming to IEC 61812-1
- Minimum pulse duration: 100 ms (with load in parallel), 30 ms
- Reset time: 120 ms (on de-energisation)
- Immunity to micro breaks: <= 10 ms
- power consumption in VA: 3 VA at 240 V AC
- power consumption in W: 1.5 W at 240 V
- switching capacity in VA: 2000 VA
- Minimum switching current: 10 mA 5 V DC
- Maximum switching current: 8:00 AM
- Maximum switching voltage: 250 V AC
- Delay response: < 100 ms
- Creepage distance: 4 kV/3 conforming to IEC 60664-1
- Safety reliability data: MTTFd = 308.2 years, B10d = 280000
- status LED: Green LED backlight (steady) dial pointer indication, Yellow LED (steady) output relay energized, Yellow LED (fast flashing) timing in progress and output relay de-energized, Yellow LED (slow flashing) timing in progress and output relay energized
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on RE22R1AMR . Santa Clara Systems carries 10,327 items from Telemecanique.
- On-Delay Timing Relay - 0.05s?300h - 24?240v Ac/dc - 1c/o
Alternates
Common Typos
- RE22RIAMR
- RE22RLAMR
- RE2ZR1AMR
- RE2ZRIAMR
- RE2ZRLAMR
- REZ2R1AMR
- REZ2RIAMR
- REZ2RLAMR
- REZZR1AMR
- REZZRIAMR
- REZZRLAMR
Appended Numbers
- RE22R1AMR-A
- RE22R1AMR-B
- RE22R1AMR-C
- RE22R1AMR-D
- RE22R1AMR-E
- RE22R1AMR-F
- RE22R1AMR-G
- RE22R1AMR-H
- RE22R1AMR-I
- RE22R1AMR-J
- RE22R1AMR-K
- RE22R1AMR-L
- RE22R1AMR-M
- RE22R1AMR-N
- RE22R1AMR-O
- RE22R1AMR-P
- RE22R1AMR-Q
- RE22R1AMR-R
- RE22R1AMR-S
- RE22R1AMR-T
- RE22R1AMR-U
- RE22R1AMR-V
- RE22R1AMR-W
- RE22R1AMR-X
- RE22R1AMR-Y
- RE22R1AMR-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier