- Description: extension module LTME TeSys T - 100..240 V AC
- Product weight: 0.46 lb(US) (0.21 kg)
- IP degree of protection: IP20
- Standards: CSA C22.2 No 14, IEC 60947-4-1, IACS E10, UL 508, EN 60947-4-1
- Device short name: LTME
- Width: 1.77 in (45 mm)
- Height: 2.4 in (61 mm)
- Depth: 4.75 in (120.7 mm)
- Protective treatment: 12 x 24 hour cycles conforming to EN/IEC 60068-2-30, 48 h conforming to EN/IEC 60070-2-11, TH conforming to EN/IEC 60068
- [Ui] rated insulation voltage: 690 V conforming to CSA C22.2 No 14, 690 V conforming to EN/IEC 60947-1, 690 V conforming to UL 508
- [Uimp] rated impulse withstand voltage: 4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1, 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
- Operating altitude: <= 6561.68 ft. (2000 m) without derating
- Tightening torque: 4.42...5.31 lbf.in (0.5...0.6 N.m), 0.12 in (3 mm) flat screwdriver control circuit
- Connections - terminals: Connector, 1 flexible cable with cable end 0...0 in (0.25...2.5 mm) /AWG 24...AWG 14 control circuit, Connector, 1 flexible cable without cable end 0...0 in (0.2...2.5 mm) /AWG 24...AWG 14 control circuit, Connector, 1 flexible cable without cable end 0...0 in (0.25...2.5 mm) /AWG 24...AWG 14 control circuit, Connector, 1 solid cable without cable end 0...0 in (0.2...2.5 mm) /AWG 24...AWG 14 control circuit, Connector, 2 flexible cable with cable end 0...0 in (0.2...1 mm) /AWG 24...AWG 14 control circuit, Connector, 2 flexible cable without cable end 0...0 in (0.2...1.5 mm) /AWG 24...AWG 14 control circuit, Connector, 2 flexible cable without cable end 0...0 in (0.5...1.5 mm) /AWG 24...AWG 14 control circuit, Connector, 2 solid cable without cable end 0...0 in (0.2...1 mm) /AWG 24...AWG 14 control circuit
- Range: TeSys
- Operating rate: 1800 cyc/h
- Product name: TeSys T
- Overvoltage category: III
- Product certifications: DNV, BV, RINA, KERI, RMRoS, CSA, C-Tick, LROS (Lloyds register of shipping), ABS, UL, NOM, GL, ATEX, CCC, EAC
- Logic input number: 4
- Product or component type: Extension module
- Input current: 3.1 mA at 100 V, 7.5 mA at 240 V
- Device application: Equipment monitoring and control
- Input/output type: Logic input : 79...264 V and <= 15 mA 25 ms (at state 1), Logic input : 0...40 V and 2 A...15 mA for 25 ms (at state 0)
- Fire resistance: 1202 F (650 C) conforming to EN/IEC 60695-2-12, 1760 F (960 C) conforming to UL 94
- Range compatibility: TeSys T LTMR motor controller
- Maximum operating frequency: 2 Hz
- Ambient air temperature for operation: -4...140 F (-20...60 C)
- Supply: Via the controller
- Ambient air temperature for storage: -40...176 F (-40...80 C)
- Contacts type and composition: Without
- Metering type: Calculated active and reactive energy (+/- W.h, +/- VAR.h), Frequency, Power factor, Active power P, P1, P2, P3, Voltage U21, U32, U13, V1, V2, V3, Reactive power Q, Q1, Q2, Q3, Imbalance voltage
- Mechanical robustness: shocks half sine wave acceleration (15 Gn for 11 ms) conforming to EN/IEC 60068-2-27, ? vibrations mounted on symmetrical rail (1 Gn, 5...300 Hz) conforming to EN/IEC 60068-2-6, ? vibrations plate mounted (4 Gn, 5...300 Hz) conforming to EN/IEC 60068-2-6
- Measurement accuracy: 3 % power factor (cos ? > 0.6), 1 % voltage (100...830 V), 5 % active and reactive power
- Connection pitch: 0.2 in (5.08 mm)
- Pollution degree: 3
- Electromagnetic compatibility: electrostatic discharge 3 (8 kV air, 6 kV contact), conforming to EN/IEC 61000-4-2, ? fast transients immunity test other circuits level 3 (2 kV), conforming to EN/IEC 61000-4-4, ? fast transients immunity test on supply and relay outputs level 4 (4 kV), conforming to EN/IEC 61000-4-4, ? conducted RF disturbances (10 V), conforming to EN/IEC 61000-4-6, ? surges serial mode (1 kV) control circuit, conforming to EN/IEC 61000-4-5, ? surges common mode (2 kV) communication, conforming to EN/IEC 61000-4-5, ? surges serial mode (2 kV) voltage inputs, conforming to EN/IEC 61000-4-5, ? surges common mode (4 kV) voltage inputs, conforming to EN/IEC 61000-4-5, ? surges common mode (2 kV) control circuit, conforming to EN/IEC 61000-4-5
- Compatibility code: LTME
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LTMEV40FM . Santa Clara Systems carries 10,327 items from Telemecanique.
- Extension Module Ltme Tesys T - 100..240 V Ac
Alternates
Common Typos
- 1TMEV40FM
- 1TMEV4OFM
- ITMEV40FM
- ITMEV4OFM
- LTMEV4OFM
Appended Numbers
- LTMEV40FM-A
- LTMEV40FM-B
- LTMEV40FM-C
- LTMEV40FM-D
- LTMEV40FM-E
- LTMEV40FM-F
- LTMEV40FM-G
- LTMEV40FM-H
- LTMEV40FM-I
- LTMEV40FM-J
- LTMEV40FM-K
- LTMEV40FM-L
- LTMEV40FM-M
- LTMEV40FM-N
- LTMEV40FM-O
- LTMEV40FM-P
- LTMEV40FM-Q
- LTMEV40FM-R
- LTMEV40FM-S
- LTMEV40FM-T
- LTMEV40FM-U
- LTMEV40FM-V
- LTMEV40FM-W
- LTMEV40FM-X
- LTMEV40FM-Y
- LTMEV40FM-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier