• Telemecanique LC1 D12V7 Contactor Product Image
  • Telemecanique LC1 D12V7 Contactor Product Image
  • Telemecanique LC1 D12V7 Contactor Product Image
  • Telemecanique LC1 D12V7 Contactor Product Image
  • Telemecanique LC1 D12V7 Barcode

LC1D12V7

Get a Quote

Current response time:

8 Minutes 49 Seconds
  • Description: Contactor
  • IP degree of protection: IP20 front face conforming to IEC 60529
  • Standards: CSA C22.2 No 14
  • Device short name: LC1D
  • Width: 45 mm
  • Height: 77 mm
  • Depth: 86 mm
  • Protective treatment: TH conforming to IEC 60068-2-30
  • [Ui] rated insulation voltage: Power circuit: 690 V conforming to IEC 60947-4-1
  • [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947
  • Operating altitude: 3000 m without
  • Mechanical durability: 15 Mcycles
  • Tightening torque: Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat 6 mm
  • Connections - terminals: Power circuit: screw clamp terminals 1 cable(s) 14 mmflexible without cable end
  • Range: TeSys
  • Mounting support: Plate
  • [Ith] conventional free air thermal current: 25 A (at 60 C) for power circuit
  • Product name: TeSys D
  • [Uc] control circuit voltage: 400 V AC 50/60 Hz
  • Electrical durability: 2 Mcycles 12 A AC-3 at Ue <= 440 V
  • Insulation resistance: > 10 MOhm for signalling circuit
  • motor power kW: 3 kW at 220...230 V AC 50/60 Hz (AC-3)
  • [Ie] rated operational current: 25 A (at <60 C) at <= 440 V AC AC-1 for power circuit
  • Control circuit voltage limits: Drop-out: 0.3...0.6 Uc AC 50/60 Hz (at 60 C)
  • Poles description: 3P
  • Overvoltage category: III
  • Operating time: 12...22 ms closing
  • Associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1
  • Control circuit type: AC at 50/60 Hz
  • Product or component type: Contactor
  • Contactor application: Motor control
  • Utilisation category: AC-3
  • Power pole contact composition: 3 NO
  • [Ue] rated operational voltage: Power circuit: <= 690 V AC 25...400 Hz
  • motor power HP (UL / CSA): 0.5 hp at 115 V AC 50/60 Hz for 1 phase motors
  • Auxiliary contact composition: 1 NO + 1 NC
  • Irms rated making capacity: 250 A at 440 V for power circuit conforming to IEC 60947
  • Rated breaking capacity: 250 A at 440 V for power circuit conforming to IEC 60947
  • [Icw] rated short-time withstand current: 105 A 40 C - 10 s for power circuit
  • Average impedance: 2.5 mOhm - Ith 25 A 50 Hz for power circuit
  • Power dissipation per pole: 0.36 W AC-3
  • Safety cover: With
  • Product certifications: GL
  • Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
  • Maximum operating rate: 3600 cyc/h 60 C
  • Coil technology: Without built-in suppressor module
  • inrush power in VA: 70 VA 60 Hz cos phi 0.75 (at 20 C)
  • hold-in power consumption in VA: 7.5 VA 60 Hz cos phi 0.3 (at 20 C)
  • Heat dissipation: 23 W at 50/60 Hz
  • Auxiliary contacts type: type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
  • Signalling circuit frequency: 25...400 Hz
  • Minimum switching current: 5 mA for signalling circuit
  • Minimum switching voltage: 17 V for signalling circuit
  • Non-overlap time: 1.5 ms on de-energisation between NC and NO contact
  • Pollution degree: 3
  • Ambient air temperature for operation: -560 C
  • Ambient air temperature for storage: -6080 C
  • Permissible ambient air temperature around the device: -4070 C at Uc
  • Fire resistance: 850 C conforming to IEC 60695-2-1
  • Flame retardance: V1 conforming to UL 94
  • Mechanical robustness: Vibrations contactor open: 2 Gn, 5...300 Hz
  • Toxic heavy metal free: Yes
  • Mercury free: Yes
  • Circularity Profile: End of Life Information
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1D12V7 . Santa Clara Systems carries 10,327 items from Telemecanique.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.

Alternates

    Common Typos

    • 1C1D12V7
    • 1C1D1ZV7
    • 1C1DI2V7
    • 1C1DIZV7
    • 1C1DL2V7
    • 1C1DLZV7
    • 1CID12V7
    • 1CID1ZV7
    • 1CIDI2V7
    • LC1D1ZV7
    • LC1DI2V7
    • LC1DIZV7
    • LC1DL2V7
    • LC1DLZV7
    • LCID12V7
    • LCID1ZV7
    • LCIDI2V7
    • LCIDIZV7
    • LCIDL2V7
    • LCIDLZV7
    • LCLD12V7
    • LCLD1ZV7
    • LCLDI2V7
    • LCLDIZV7
    • LCLDL2V7
    • LCLDLZV7

    Appended Numbers

    • LC1D12V7-A
    • LC1D12V7-B
    • LC1D12V7-C
    • LC1D12V7-D
    • LC1D12V7-E
    • LC1D12V7-F
    • LC1D12V7-G
    • LC1D12V7-H
    • LC1D12V7-I
    • LC1D12V7-J
    • LC1D12V7-K
    • LC1D12V7-L
    • LC1D12V7-M
    • LC1D12V7-N
    • LC1D12V7-O
    • LC1D12V7-P
    • LC1D12V7-Q
    • LC1D12V7-R
    • LC1D12V7-S
    • LC1D12V7-T
    • LC1D12V7-U
    • LC1D12V7-V
    • LC1D12V7-W
    • LC1D12V7-X
    • LC1D12V7-Y
    • LC1D12V7-Z

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo