- Description: TeSys GV2 - Motor circuit breaker - thermal-magnetic - 0.16?0.25 A
- IP degree of protection: IP20 conforming to IEC 60529
- Standards: VDE 0660, IEC 60947-4-1, NF C 63-650, CSA C22.2, NF C 63-120, VDE 0113, IEC 60947-1, IEC 60947-2, NF C 79-130, EN 60204, UL 508
- Device short name: GV2P
- Width: 1.77 in (45 mm)
- Height: 3.5 in (89 mm)
- Depth: 3.82 in (97 mm)
- Protective treatment: TH
- [Ui] rated insulation voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2
- Operating altitude: 6561.68 ft. (2000 m)
- Mechanical durability: 100000 cycles
- Tightening torque: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals
- Connections - terminals: Screw clamp terminals 2 cable(s) 0...0.01 in (1...6 mm) - cable stiffness : solid, Screw clamp terminals 2 cable(s) 0...0.01 in (1.5...6 mm) - cable stiffness : flexible - without cable end, Screw clamp terminals 2 cable(s) 0...0.01 in (1...4 mm) - cable stiffness : flexible - with cable end
- Range: TeSys
- Mounting support: Rail, Plate
- [Ith] conventional free air thermal current: 0.25 A conforming to IEC 60947-4-1
- System Voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
- Operating rate: 25 cyc/h
- Product name: TeSys GV2
- Electrical durability: 100000 cycles AC-3 at 440 V
- motor power kW: 0.06 kW at 400/415 V AC 50/60 Hz
- Utilization category: AC-3 conforming to IEC 60947-4-1, Category A conforming to IEC 60947-2
- Poles description: 3P
- Control type: Rotary knob
- Breaking capacity: 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
- Mounting position: Vertical, Horizontal
- Network type: AC
- Product certifications: GL, UL, TSE, BV, CSA, RINA, CCC, LROS (Lloyds register of shipping), EZU, EAC, ATEX, DNV, UL 508 type E
- Product or component type: Circuit breaker
- Network frequency: 50/60 Hz conforming to IEC 60947-4-1
- Device application: Motor
- Mounting mode: By Clips / By Screws
- IK degree of protection: IK04
- Trip unit technology: Thermal-magnetic
- Ambient air temperature for operation: -4...140 F (-20...60 C)
- Ambient air temperature for storage: -40...176 F (-40...80 C)
- Fire resistance: 1760 F (960 C) conforming to IEC 60695-2-1
- [Ics] rated service short-circuit breaking capacity: 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
- [In] rated current: 0.16...0.25 A
- Trip unit rating: 0.16...0.25 A
- Magnetic tripping current: 2.4 A
- Power dissipation per pole: 2.5 W
- Rated duty: Continuous conforming to IEC 60947-4-1
- Suitability for isolation: Yes conforming to IEC 60947-1
- Phase failure sensitivity: Yes conforming to IEC 60947-4-1
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on GV2P02 . Santa Clara Systems carries 10,417 items from Telemecanique.
- Tesys Gv2 - Motor Circuit Breaker - Thermal-Magnetic - 0.16?0.25 A
Alternates
Common Typos
- 6V2P02
- 6V2P0Z
- 6V2PO2
- 6V2POZ
- 6VZP02
- 6VZP0Z
- 6VZPO2
- 6VZPOZ
- GV2P0Z
- GV2PO2
- GV2POZ
- GVZP02
- GVZP0Z
- GVZPO2
- GVZPOZ
Appended Numbers
- GV2P02-A
- GV2P02-B
- GV2P02-C
- GV2P02-D
- GV2P02-E
- GV2P02-F
- GV2P02-G
- GV2P02-H
- GV2P02-I
- GV2P02-J
- GV2P02-K
- GV2P02-L
- GV2P02-M
- GV2P02-N
- GV2P02-O
- GV2P02-P
- GV2P02-Q
- GV2P02-R
- GV2P02-S
- GV2P02-T
- GV2P02-U
- GV2P02-V
- GV2P02-W
- GV2P02-X
- GV2P02-Y
- GV2P02-Z
More Products Like This
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier