- Description: Light Curtain Set
- Footnotes: *1 OFF?ON return time is 125 ms. *2 Note the derating illustrated in the graph to the right when using PNP output. *3 This includes situations in which the SL-C Series is off and in which the power supply line is disconnected. *4 The wiring resistance between the OSSD output and the connected equipment (excluding the wiring resistance of the optional dedicated cable) must be 2.5 - or less to ensure that the SL-C Series operate correctly. If using the NPN output *5 The SL-CHM Series attains a protection rating of IP65 because the main unit's sensor is enclosed in an aluminum case.
- Response time: 15 ms *1
- Light source: Infrared LED (850 nm)
- Effective aperture angle: Max. 2.5 (when operating distance is at least 3 m 9.8')
- Operation mode: Turned on when light is being applied to all optical axes (excluding when the blanking function is used)
- Detection capability: 25 mm (when the blanking function is not used)
- No. of beam axes: 48
- Detection zone: 940 mm 37.01"
- Protection area: 985 mm38.78"
- DetectingdistanceTransmitter lens: Norbornene plasticReceiver lens cover: Polyarylate: 0.25 to 9 m
- Beam axis interval: 20 mm 0.79"
- OSSD output - Output type: 2 outputs each for PNP and NPN, Can be switched using the connection connector cable
- OSSD output - Max. load current: 300 mA *2
- OSSD output - OFF-state voltage: 2.5 V (with a cable length of 7 m 23.0')
- OSSD output - Leakage current: 100 A maximum*3
- OSSD output - Max. capacitive load: 2.2 F (with a load resistance of 100 ?)
- OSSD output - Load wiring resistance: 2.5 - maximum*4
- Approved standards - EMC - EMS: IEC61496-1, EN61496-1, UL61496-1
- Approved standards - EMC - EMI: EN55011 Class A, FCC Part15 Class A
- Approved standards - Safety: IEC61496-1, EN61496-1, UL61496-1 (type 4 ESPE),IEC61496-2, EN61496-2, UL61496-2 (type 4 AOPD),UL508
- Current consumption - Transmitter: 87 mA
- Current consumption - Receiver: 90 mA
- Rating - Power voltage: 24 VDC 10% (Ripple P-P 10% or less)
- Environmental resistance - Enclosure rating: IP65 (IEC 60529)*5
- Environmental resistance - Ambient temperature: -10 to +55C 14 to 131F, No freezing
- Environmental resistance - Ambient temperature for storage: -10 to +60C 14 to 140F, No freezing
- Environmental resistance - Relative humidity: 35 to 85%RH (no condensation)
- Environmental resistance - Storage relative humidity: 35 to 95%RH (no condensation)
- Environmental resistance - Operating ambient luminance: Incandescent lamp: 5,000 lux or less, sunlight: 20,000 lux or less
- Environmental resistance - Vibration: 10 to 55 Hz, 0.7 mm 0.03", double amplitude, 20 sweeps each in X, Y, and Z directions
- Environmental resistance - Shock resistance: 100 m/s2 (Approx 10G) 16 ms pulse, in X, Y, Z directions 1000 times each axis
- Weight - Transmitter: Approx 3.2 kg
- Weight - Receiver: Approx 3.3 kg
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on SL-C48HM . Santa Clara Systems carries 2,104 items from Keyence.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.
Alternates
Common Typos
- 51-C48HM
- 51-C4BHM
- 5I-C48HM
- 5I-C4BHM
- 5L-C48HM
- 5L-C4BHM
- S1-C48HM
- S1-C4BHM
- SI-C48HM
- SI-C4BHM
- SL-C4BHM
Appended Numbers
- SL-C48HM-A
- SL-C48HM-B
- SL-C48HM-C
- SL-C48HM-D
- SL-C48HM-E
- SL-C48HM-F
- SL-C48HM-G
- SL-C48HM-H
- SL-C48HM-I
- SL-C48HM-J
- SL-C48HM-K
- SL-C48HM-L
- SL-C48HM-M
- SL-C48HM-N
- SL-C48HM-O
- SL-C48HM-P
- SL-C48HM-Q
- SL-C48HM-R
- SL-C48HM-S
- SL-C48HM-T
- SL-C48HM-U
- SL-C48HM-V
- SL-C48HM-W
- SL-C48HM-X
- SL-C48HM-Y
- SL-C48HM-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier