  • Description: Contactor | 1SBL141001R8410
  • Product ID: 1SBL141001R8410
  • Extended Product Type: A9-30-10 110V 50Hz / 110-120V 60Hz
  • Product Net Weight: 0.340 kg
  • Product Net Width: 44 mm
  • Product Net Height: 74 mm
  • Product Net Depth: 74 mm
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 C Close to Contactor for Storage -60 ... +80 C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 C Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 C
  • Standards: Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
  • Rated Impulse Withstand Voltage (U<sub>imp</sub>): 8 kV
  • Rated Insulation Voltage (U<sub>i</sub>): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
  • Terminal Type: Screw Terminals
  • Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz
  • Number of Auxiliary Contacts NO: 1
  • Number of Auxiliary Contacts NC: 0
  • Mechanical Durability: 10 million
  • Connecting Capacity Main Circuit: Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm
  • GOST Certificate: GOST_POCCFRME77B07175
  • Maximum Operating Altitude Permissible: 3000 m
  • Rated Control Circuit Voltage (U<sub>c</sub>): 50 Hz 110 V 60 Hz 110 120 V
  • Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
  • Maximum Mechanical Switching Frequency: 3600 cycles per hour
  • Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm
  • Operate Time: Between Coil Energization and NO Contact Closing 10 ... 26 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms
  • Country of Origin: France (FR)
  • Number of Main Contacts NO: 3
  • GL Certificate: DNV-GL_TAE00000TX
  • Number of Main Contacts NC: 0
  • Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 25 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 690 V 90 A
  • Coil Consumption: Average Holding Value 50 / 60 Hz 8 V&#183;A Average Holding Value 50 / 60 Hz 2 W Average Pull-in Value 50 Hz 74 V&#183;A Average Pull-in Value 60 Hz 70 V&#183;A
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at 55 C) C
  • Connecting terminals (delivered in open position) Main poles: M 3.5 (+,-) pozidriv 2 screws with cable clamp
  • EAN: 3471522031846
  • Made To Order: No
  • Product Sales Status: Inactive
  • Quote Only: No
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85369085
  • Package Level 1 Width: 78 mm
  • Package Level 1 Length: 76 mm
  • Package Level 1 Height: 47 mm
  • Package Level 1 Gross Weight: 0.34 kg
  • Package Level 1 EAN: 3471522031846
  • Package Level 2 Units: 63 piece
  • Package Level 3 Units: 1220 piece
  • Package Level 1 Units: 1 piece
  • Rated Operational Voltage: Main Circuit 690 V
  • Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 26 A acc. to IEC 60947-5-1, q = 40 C 16 A
  • Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 40 C 25 A (690 V) 55 C 22 A (690 V) 70 C 18 A
  • Rated Operational Current AC-3 (I<sub>e</sub>): (220 / 230 / 240 V) 55 C 9 A (380 / 400 V) 55 C 9 A (415 V) 55 C 9 A (440 V) 55 C 9 A (500 V) 55 C 9 A (690 V) 55 C 7 A
  • Rated Operational Power AC-3 (P<sub>e</sub>): (220 / 230 / 240 V) 2.2 kW (380 / 400 V) 4 kW (415 V) 4 kW (440 V) 4 kW (500 V) 5.5 kW (690 V) 5.5 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
  • Rated Operational Current AC-15 (I<sub>e</sub>): (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
  • Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 100 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 26 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 50 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 250 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 60 A for 0.1 s 140 A for 1 s 100 A
  • Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour
  • Rated Operational Current DC-13 (I<sub>e</sub>): (125 V) 1.1 / 138 A (24 V) 6 / 144 A (250 V) 0.55 / 138 A (48 V) 2.8 / 134 A (72 V) 2 / 144 A
  • Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 20 g Closed, Shock Direction: B1 10 g Open, Shock Direction: B1 5 g Shock Direction: B2 15 g Shock Direction: C1 20 g Shock Direction: C2 20 g
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Instructions and Manuals: FPTC407721P0001
  • BV Certificate: BV_2634H07559D0
  • CB Certificate: CB_FR_602227A
  • CCC Certificate: CCC_2013010304615753 CCC_2004010309130463
  • CSA Certificate: CSA_1041746
  • cUL Certificate: UL_20160205-E312527-10-2
  • Data Sheet, Technical Information: 1SBC100122C0202_Ch02
  • Declaration of Conformity - CE: 1SBD250801U1000
  • DNV Certificate: DNV-GL_TAE00000TX
  • EAC Certificate: EAC_RU C-FR ME77 B01010
  • LOVAG Certificate: LOVAG_FR97037
  • LR Certificate: LRS_9830011E4
  • RINA Certificate: RINA_ELE128713XG001
  • RMRS Certificate: RMRS_0507015250
  • RoHS Information: 1SBD350050R1000
  • UL Certificate: UL_071301E39231
  • UL Listing Card: UL_E312527
  • E-nummer: 3227683
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • ETIM 6: EC000066 - Power contactor, AC switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on A9-30-10-84 . Santa Clara Systems carries 36,928 items from ABB.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.

Alternates

  • A9 30 10 84
  • A9301084
  • 1SBL141001R8410

Common Typos

  • A9-30-10-B4
  • A9-30-1O-84
  • A9-30-1O-B4
  • A9-30-I0-84
  • A9-30-I0-B4
  • A9-30-IO-84
  • A9-30-IO-B4
  • A9-30-L0-84
  • A9-30-L0-B4
  • A9-30-LO-84
  • A9-30-LO-B4
  • A9-3O-10-84
  • A9-3O-10-B4
  • A9-3O-1O-84
  • A9-3O-1O-B4
  • A9-3O-I0-84
  • A9-3O-I0-B4
  • A9-3O-IO-84
  • A9-3O-IO-B4
  • A9-3O-L0-84
  • A9-3O-L0-B4
  • A9-3O-LO-84
  • A9-3O-LO-B4

Appended Numbers

  • A9-30-10-84-A
  • A9-30-10-84-B
  • A9-30-10-84-C
  • A9-30-10-84-D
  • A9-30-10-84-E
  • A9-30-10-84-F
  • A9-30-10-84-G
  • A9-30-10-84-H
  • A9-30-10-84-I
  • A9-30-10-84-J
  • A9-30-10-84-K
  • A9-30-10-84-L
  • A9-30-10-84-M
  • A9-30-10-84-N
  • A9-30-10-84-O
  • A9-30-10-84-P
  • A9-30-10-84-Q
  • A9-30-10-84-R
  • A9-30-10-84-S
  • A9-30-10-84-T
  • A9-30-10-84-U
  • A9-30-10-84-V
  • A9-30-10-84-W
  • A9-30-10-84-X
  • A9-30-10-84-Y
  • A9-30-10-84-Z

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo