- Description: A145-30-22 110-115V 50Hz / 115V 60Hz Contactor
- Product ID: 1SFL471001R8922
- Extended Product Type: 1SFL471001R8922
- Product Net Weight: 3.500 kg
- Product Net Width: 123.5 mm
- Product Net Height: 196.0 mm
- Product Net Depth: 160.0 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
- Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25+50 C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40+70 C Close to Contactor for Storage -40+70 C
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): Main Circuit 8 kV
- Rated Insulation Voltage (U<sub>i</sub>): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
- Terminal Type: Main Circuit: Bars
- Rated Frequency (f): Main Circuit 50/60 Hz
- Number of Auxiliary Contacts NO: 2
- Number of Auxiliary Contacts NC: 2
- Mechanical Durability: 5 million
- Connecting Capacity Main Circuit: Rigid Al-Cable 1x25150 mm Bar 24 mm Rigid Cu-Cable 1x6185 mm
- Maximum Operating Voltage UL/CSA: Main Circuit 600 V
- Maximum Operating Altitude Permissible: 3000 m
- Rated Control Circuit Voltage (U<sub>c</sub>): 60 Hz 115 V 50 Hz 110 115 V
- Maximum Mechanical Switching Frequency: 3600 cycles per hour
- Connecting Capacity Auxiliary Circuit: Solid 2x14 mm Flexible with Insulated Ferrule 2x0.752.5 mm Stranded 1x14 mm Flexible 2x0.752.5 mm Flexible with Ferrule 1x0.752.5 mm
- Operate Time: Between Coil Energization and NO Contact Closing 13 ... 27 ms Between Coil De-energization and NO Contact Opening 9 ... 13 ms Between Coil De-energization and NC Contact Closing 5 ... 10 ms Between Coil Energization and NC Contact Opening 8 ... 22 ms
- Number of Main Contacts NO: 3
- GL Certificate: GL_15529-00HH
- Number of Main Contacts NC: 0
- Short-Circuit Protective Devices: gG Type Fuses 315 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1500 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1200 A
- Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 600 V·A Holding at Max. Rated Control Circuit Voltage 50 Hz 35 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 550 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 40 V·A
- Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at 70 C) C
- Connecting terminals (delivered in open position) Main poles: Flat type c/w screws and bolts
- Horsepower Rating UL/CSA: (208 V AC) Three Phase 40 Hp (440 ... 480 V AC) Three Phase 100 Hp (550 ... 600 V AC) Three Phase 125 Hp (220 ... 240 V AC) Three Phase 50 Hp (200 V AC) Three Phase 40 Hp
- General Use Rating UL/CSA: (600 V AC) 230 A
- EAN: 7320500217313
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Package Level 1 Width: 170 mm
- Package Level 1 Length: 180 mm
- Package Level 1 Height: 245 mm
- Package Level 1 Gross Weight: 3.5 kg
- Package Level 1 EAN: 7320500217313
- Package Level 1 Units: 1 piece
- Rated Operational Voltage: Main Circuit 690 V
- Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 250 A
- Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 55 C 230 A (690 V) 40 C 250 A (1000 V) 40 C 180 A (1000 V) 55 C 180 A (690 V) 70 C 180 A (1000 V) 70 C 180 A
- Rated Operational Current AC-3 (I<sub>e</sub>): (1000 V) 55 C 80 A (690 V) 55 C 120 A (415 V) 55 C 145 A (220 / 230 / 240 V) 55 C 145 A (440 V) 55 C 145 A (380 / 400 V) 55 C 145 A (500 V) 55 C 145 A
- Rated Operational Power AC-3 (P<sub>e</sub>): (500 V) 90 kW (690 V) 110 kW (220 / 230 / 240 V) 45 kW (380 / 400 V) 75 kW (440 V) 75 kW (415 V) 75 kW
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
- Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 280 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 800 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 600 A
- Maximum Electrical Switching Frequency: AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 150 cycles per hour
- Rated Operational Current DC-1 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 C 250 A (220 V) 3 Poles in Series, 40 C 250 A
- Rated Operational Current DC-3 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 C 250 A (220 V) 3 Poles in Series, 40 C 250 A
- Rated Operational Current DC-5 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 C 250 A (220 V) 3 Poles in Series, 40 C 250 A
- Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 5 g Shock Direction: C2 5 g Shock Direction: B2 5 g Shock Direction: C1 5 g Shock Direction: B1 5 g
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Instructions and Manuals: 1SFC380003-89
- BV Certificate: 09826/C0 BV
- CB Certificate: SE-69488
- CCC Certificate: CQC_2002010304011010
- Data Sheet, Technical Information: 1SBC100122C0202
- Declaration of Conformity - CE: 1SFA1-45
- DNV Certificate: DNV_E-12191
- LOVAG Certificate: IT99027
- LR Certificate: LR_12-70003
- RINA Certificate: ELE060313XG/001
- RMRS Certificate: RMRS_12-03683-315
- RoHS Information: 1SFC101046D0203
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- UNSPSC: 39121529
- Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on A145-30-22-89 . Santa Clara Systems carries 36,937 items from ABB.
- Versions From 24….690 Ac
- 50 And 60 Hz
- A 3-Phase Contactor Suitable For Various Applications Such As Motor Starting
- Isolation
- By-Pass And Distribution Application Up To Max 1000 V.operated With Control Voltage
Alternates
- 1SFL471001R8922
- SCH.A 145-30-22 11
- SCH.A-145-30-22-11
- SCH.A145-30-2211
- SCH.A 145 30 22 11
- SCH.A 1453022 11
- SCHA145302211
Common Typos
- A145-30-22-B9
- A145-30-2Z-89
- A145-30-2Z-B9
- A145-30-Z2-89
- A145-30-Z2-B9
- A145-30-ZZ-89
- A145-30-ZZ-B9
- A145-3O-22-89
- A145-3O-22-B9
- A145-3O-2Z-89
- A145-3O-2Z-B9
- A145-3O-Z2-89
- A145-3O-Z2-B9
- A145-3O-ZZ-89
- A145-3O-ZZ-B9
- A14S-30-22-89
- A14S-30-22-B9
- A14S-30-2Z-89
- A14S-30-2Z-B9
- A14S-30-Z2-89
- A14S-30-Z2-B9
- A14S-30-ZZ-89
- A14S-30-ZZ-B9
- A14S-3O-22-89
- A14S-3O-22-B9
- A14S-3O-2Z-89
Appended Numbers
- A145-30-22-89-A
- A145-30-22-89-B
- A145-30-22-89-C
- A145-30-22-89-D
- A145-30-22-89-E
- A145-30-22-89-F
- A145-30-22-89-G
- A145-30-22-89-H
- A145-30-22-89-I
- A145-30-22-89-J
- A145-30-22-89-K
- A145-30-22-89-L
- A145-30-22-89-M
- A145-30-22-89-N
- A145-30-22-89-O
- A145-30-22-89-P
- A145-30-22-89-Q
- A145-30-22-89-R
- A145-30-22-89-S
- A145-30-22-89-T
- A145-30-22-89-U
- A145-30-22-89-V
- A145-30-22-89-W
- A145-30-22-89-X
- A145-30-22-89-Y
- A145-30-22-89-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier