- Description: TeSys GV3-Circuit breaker-thermal-magnetic - 48?65A - EverLink BTR connectors
- Product weight: 2.12 lb(US) (0.96 kg)
- IP degree of protection: IP20 conforming to IEC 60529
- Standards: EN/IEC 60947-4-1, CSA C22.2 No 14-05 type E, EN/IEC 60947-1, EN/IEC 60947-2, UL 508 type E
- Device short name: GV3P
- Width: 2.17 in (55 mm)
- Height: 5.2 in (132 mm)
- Depth: 5.35 in (136 mm)
- Protective treatment: TH
- [Ui] rated insulation voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2
- Operating altitude: 9842.52 ft. (3000 m)
- Mechanical durability: 50000 cycles
- Tightening torque: 8 N.m - on EverLink BTR screw connectors- cable 35 mm, 44.25 lbf.in (5 N.m) - on EverLink BTR screw connectors- cable 0.04 in (25 mm)
- Connections - terminals: EverLink BTR screw connectors 2 cable(s) 0...0.04 in (1...25 mm) - cable stiffness : solid, EverLink BTR screw connectors 2 cable(s) 0...0.04 in (1...25 mm) - cable stiffness : flexible - without cable end, EverLink BTR screw connectors 2 cable(s) 0...0.04 in (1...25 mm) - cable stiffness : flexible - with cable end
- Range: TeSys
- Mounting support: Plate, Rail
- [Ith] conventional free air thermal current: 65 A conforming to IEC 60947-4-1
- System Voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
- Operating rate: 25 cyc/h
- Product name: TeSys GV3
- Electrical durability: 50000 cycles AC-3 at 440 V In
- motor power kW: 45 kW at 500 V AC 50/60 Hz, 55 kWat 690 V AC 50/60 Hz, 30 kWat 400/415 V AC 50/60 Hz
- Utilization category: AC-3 conforming to IEC 60947-4-1, Category A conforming to IEC 60947-2
- Poles description: 3P
- Control type: Rotary knob
- Breaking capacity: 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2, 12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
- Mounting position: Horizontal, Vertical
- Network type: AC
- Product certifications: ATEX, UL, RINA, LROS (pending), CCC, DNV, CSA, BV, EAC, GL
- Product or component type: Circuit breaker
- Network frequency: 50/60 Hz conforming to IEC 60947-4-1
- Device application: Motor
- Mounting mode: By Clips / By Screws
- IK degree of protection: IK09
- Trip unit technology: Thermal-magnetic
- Ambient air temperature for operation: -4...140 F (-20...60 C)
- Ambient air temperature for storage: -40...176 F (-40...80 C)
- Fire resistance: 1760 F (960 C) conforming to IEC 60695-2-1
- [Ics] rated service short-circuit breaking capacity: 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2, 50 %at 500 V AC 50/60 Hz conforming to IEC 60947-2, 50 %at 690 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
- [In] rated current: 48...65 A
- Trip unit rating: 48...65 A
- Magnetic tripping current: 910 A
- Power dissipation per pole: 8 W
- Rated duty: Continuous conforming to IEC 60947-4-1
- Suitability for isolation: Yes conforming to IEC 60947-1
- Phase failure sensitivity: Yes conforming to IEC 60947-4-1
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on GV3P65 . Santa Clara Systems carries 10,327 items from Telemecanique.
- Tesys Gv3-Circuit Breaker-Thermal-Magnetic - 48?65a - Everlink Btr Connectors
Alternates
Common Typos
- 6V3P65
- 6V3P6S
- 6V3PG5
- 6V3PGS
- GV3P6S
- GV3PG5
- GV3PGS
Appended Numbers
- GV3P65-A
- GV3P65-B
- GV3P65-C
- GV3P65-D
- GV3P65-E
- GV3P65-F
- GV3P65-G
- GV3P65-H
- GV3P65-I
- GV3P65-J
- GV3P65-K
- GV3P65-L
- GV3P65-M
- GV3P65-N
- GV3P65-O
- GV3P65-P
- GV3P65-Q
- GV3P65-R
- GV3P65-S
- GV3P65-T
- GV3P65-U
- GV3P65-V
- GV3P65-W
- GV3P65-X
- GV3P65-Y
- GV3P65-Z
More Products Like This
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier