- Description: Contactor | A26-30-32-80
- Product ID: 1SBL241001R8032
- Extended Product Type: 1SBL241001R8032
- Product Net Weight: 0.660 kg
- Product Net Width: 54 mm
- Product Net Height: 90 mm
- Product Net Depth: 126.3 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
- Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 C Close to Contactor for Storage -60 ... +80 C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 C Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 C
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): 8 kV
- Rated Insulation Voltage (U<sub>i</sub>): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V acc. to UL/CSA 600 V
- Terminal Type: Screw Terminals
- Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz
- Number of Auxiliary Contacts NO: 3
- Number of Auxiliary Contacts NC: 2
- Mechanical Durability: 10 million
- Connecting Capacity Main Circuit: Flexible with Cable End 0.75 ... 4 mm Rigid Cable 1.5 ... 6 mm
- GOST Certificate: GOST_POCCFRME77B07175
- Maximum Operating Altitude Permissible: 3000 m
- Rated Control Circuit Voltage (U<sub>c</sub>): 50 Hz 220 230 V 60 Hz 230 240 V
- Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
- Maximum Mechanical Switching Frequency: 3600 cycles per hour
- Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm
- Operate Time: Between Coil Energization and NO Contact Closing 8 ... 21 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms Between Coil De-energization and NC Contact Closing 7 ... 14 ms Between Coil Energization and NC Contact Opening 6 ... 18 ms
- Country of Origin: France (FR)
- Number of Main Contacts NO: 3
- GL Certificate: DNV-GL_TAE00000TX
- Number of Main Contacts NC: 0
- Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 50 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 420 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 170 A
- Coil Consumption: Average Holding Value 50 / 60 Hz 12 V·A Average Holding Value 50 / 60 Hz 3 W Average Pull-in Value 50 Hz 125 V·A Average Pull-in Value 60 Hz 120 V·A
- Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at 55 C) C
- Connecting terminals (delivered in open position) Main poles: M 4 (+,-) pozidriv 2 screws with cable clamp
- Lead Time: 14 day(s)
- EAN: 3471522065803
- Made To Order: No
- Product Sales Status: Inactive
- Quote Only: Yes
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85369085
- Package Level 1 Width: 100 mm
- Package Level 1 Length: 149 mm
- Package Level 1 Height: 61 mm
- Package Level 1 Gross Weight: 0.66 kg
- Package Level 1 EAN: 3471522065803
- Package Level 2 Units: 20 piece
- Package Level 3 Units: 240 piece
- Package Level 1 Units: 1 piece
- Rated Operational Voltage: Main Circuit 690 V
- Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 45 A acc. to IEC 60947-5-1, q = 40 C 16 A
- Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 40 C 45 A (690 V) 55 C 40 A (690 V) 70 C 32 A
- Rated Operational Current AC-3 (I<sub>e</sub>): (220 / 230 / 240 V) 55 C 26 A (380 / 400 V) 55 C 26 A (415 V) 55 C 26 A (440 V) 55 C 26 A (500 V) 55 C 22 A (690 V) 55 C 17 A
- Rated Operational Power AC-3 (P<sub>e</sub>): (220 / 230 / 240 V) 6.5 kW (380 / 400 V) 11 kW (415 V) 11 kW (440 V) 15 kW (500 V) 15 kW (690 V) 15 kW
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
- Rated Operational Current AC-15 (I<sub>e</sub>): (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
- Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 210 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 45 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 90 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 400 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 110 A for 0.1 s 140 A for 1 s 100 A
- Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour
- Rated Operational Current DC-13 (I<sub>e</sub>): (125 V) 0.55 / 69 A (24 V) 6 / 144 A (250 V) 0.3 / 75 A (48 V) 2.8 / 134 A (72 V) 1 / 72 A
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Instructions and Manuals: FPTC407722P0001
- BV Certificate: BV_2634H07559D0
- CB Certificate: CB_FR_602227A
- CCC Certificate: CCC_2013010304615752 CCC_2004010309133982
- CSA Certificate: CSA_1033838_LR056745
- cUL Certificate: UL_071301E39231
- Data Sheet, Technical Information: 1SBC100122C0202_Ch02
- Declaration of Conformity - CE: 1SBD250801U1000
- DNV Certificate: DNV-GL_TAE00000TX
- EAC Certificate: EAC_RU C-FR ME77 B01010
- LR Certificate: LRS_9830011E4
- RINA Certificate: RINA_ELE128713XG001
- RMRS Certificate: RMRS_0507015250
- RoHS Information: 1SBD350061R1000
- UL Certificate: UL_071301E39231
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- ETIM 6: EC000066 - Power contactor, AC switching
- UNSPSC: 39121529
- Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on A26-30-32-80 . Santa Clara Systems carries 36,939 items from ABB.
- 2nd Stack With 4 Built-In Auxiliary Contacts
- Side-Mounted Add-On Auxiliary Contact Blocks (The Built-In Auxiliary Contact Elements Are Mechanically Linked) - Control Circuit: Ac Operated With Laminated Magnet Circuit - Accessories: A Wide Range Of Accessories Is Available.
- A26 Contactors Are Mainly Used For Controlling 3-Phase Motors And Generally For Controlling Power Circuits Up To 690 V Ac Or 220 V Dc. The Contactors Can Also Be Used For Many Other Applications Such As Isolation
- Capacitor Switching
- Lighting. The A... Series 2-Stack 3-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 1st Stack With 3 Main Poles And 1 Built-In Auxiliary Contact
Alternates
- 1SBL241001R8032
- A26 30 32 80
- A26303280
Common Typos
- A26-30-32-8O
- A26-30-32-B0
- A26-30-32-BO
- A26-30-3Z-80
- A26-30-3Z-8O
- A26-30-3Z-B0
- A26-30-3Z-BO
- A26-3O-32-80
- A26-3O-32-8O
- A26-3O-32-B0
- A26-3O-32-BO
- A26-3O-3Z-80
- A26-3O-3Z-8O
- A26-3O-3Z-B0
- A26-3O-3Z-BO
- A2G-30-32-80
- A2G-30-32-8O
- A2G-30-32-B0
- A2G-30-32-BO
- A2G-30-3Z-80
- A2G-30-3Z-8O
- A2G-30-3Z-B0
- A2G-30-3Z-BO
- A2G-3O-32-80
- A2G-3O-32-8O
- A2G-3O-32-B0
Appended Numbers
- A26-30-32-80-A
- A26-30-32-80-B
- A26-30-32-80-C
- A26-30-32-80-D
- A26-30-32-80-E
- A26-30-32-80-F
- A26-30-32-80-G
- A26-30-32-80-H
- A26-30-32-80-I
- A26-30-32-80-J
- A26-30-32-80-K
- A26-30-32-80-L
- A26-30-32-80-M
- A26-30-32-80-N
- A26-30-32-80-O
- A26-30-32-80-P
- A26-30-32-80-Q
- A26-30-32-80-R
- A26-30-32-80-S
- A26-30-32-80-T
- A26-30-32-80-U
- A26-30-32-80-V
- A26-30-32-80-W
- A26-30-32-80-X
- A26-30-32-80-Y
- A26-30-32-80-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier