• Telemecanique LR2K0308 TeSys K - differential thermal overload relays - 1.8...2.6 - class 10A Product Image
  • Telemecanique LR2K0308 TeSys K - differential thermal overload relays - 1.8...2.6 - class 10A Product Image
  • Telemecanique LR2K0308 TeSys K - differential thermal overload relays - 1.8...2.6 - class 10A Product Image
  • Telemecanique LR2K0308 TeSys K - differential thermal overload relays - 1.8...2.6 - class 10A Product Image
  • Telemecanique LR2K0308 Barcode

LR2K0308

Get a Quote

Current response time:

12 Minutes 2 Seconds
  • Description: TeSys K - differential thermal overload relays - 1.8...2.6 - class 10A
  • Product weight: 0.32 lb(US) (0.145 kg)
  • IP degree of protection: IP2x conforming to IEC 60529
  • Standards: IEC 60947NF C 63-650VDE 0660BS 4941
  • Device short name: LR2K
  • Width: 1.77 in (45 mm)
  • Height: 2.28 in (58 mm)
  • Depth: 2.56 in (65 mm)
  • Protective treatment: TC conforming to IEC 60068TC conforming to DIN 50016
  • [Ui] rated insulation voltage: 600 V power circuit conforming to CSA C22.2 No 14690 V power circuit conforming to BS 4941690 V power circuit conforming to IEC 60947750 V power circuit conforming to VDE 0110 group C
  • [Uimp] rated impulse withstand voltage: 6 kV
  • Operating altitude: 6561.68 ft. (2000 m) without derating
  • Tightening torque: 11.5 lbf.in (1.3 N.m) - on screw clamp terminals - with screwdriver Philips No 211.5 lbf.in (1.3 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm
  • Connections - terminals: Screw clamp terminals 1 cable(s) 0...0.01 in² (1.5...4 mm²) - cable stiffness: solidScrew clamp terminals 1 cable(s) 0...0.01 in² (0.75...4 mm²) - cable stiffness: flexible - without cable endScrew clamp terminals 1 cable(s) 0...0 in² (0.34...2.5 mm²) - cable stiffness: flexible - with cable endScrew clamp terminals 2 cable(s) 0...0.01 in² (1.5...4 mm²) - cable stiffness: solidScrew clamp terminals 2 cable(s) 0...0.01 in² (0.75...4 mm²) - cable stiffness: flexible - without cable endScrew clamp terminals 2 cable(s) 0...0 in² (0.34...1.5 mm²) - cable stiffness: flexible - with cable end
  • Range: TeSys
  • Mounting support: Plate with specific accessoriesRail with specific accessoriesUnder contactor
  • [Ith] conventional free air thermal current: 6 A for signaling circuit
  • System Voltage: <= 690 V power circuit690 V AC AC-15 signaling circuit250 V DC DC-13 signaling circuit
  • Product name: TeSys LRK
  • Associated fuse rating: 6 A gG for signaling circuit conforming to VDE 06606 A gG for signaling circuit conforming to IEC 60947
  • Control type: Red push-button trip test functionBlue push-button stop and manual resetSelector switch manual or automatic reset mode
  • Network frequency: <= 400 Hz
  • Product certifications: CSAUL
  • Product or component type: Differential thermal overload relay
  • Auxiliary contact composition: 1 NO + 1 NC
  • Relay application: Motor protection
  • Ambient air temperature for operation: -4...131 °F (-20...55 °C) without derating conforming to IEC 60947-22...140 °F (-30...60 °C) with derating conforming to IEC 60947
  • Product compatibility: LC7KLP4KLP1KLC1K
  • Ambient air temperature for storage: -40...158 °F (-40...70 °C)
  • Network type: ACDC
  • Thermal overload class: Class 10A conforming to IEC 60947-4-1
  • Power dissipation per pole: 2 W
  • Fire resistance: 1562 °F (850 °C) conforming to IEC 60695-2-1
  • Thermal protection adjustment range: 1.8...2.6 A
  • Phase failure sensitivity: Yes conforming to IEC 60947-4-1
  • Flame retardance: V1 conforming to UL 94Requirement 2 conforming to NF F 16-101Requirement 2 conforming to NF F 16-102
  • Local signaling: Trip indicator (yellow)
  • Mechanical robustness: Shocks NO contact 10 Gn for 11 ms conforming to IEC 60068-2-27Shocks NC contact 10 Gn for 11 ms conforming to IEC 60068-2-27Vibrations NO contact 2 Gn, 5...300 Hz conforming to IEC 60068-2-6Vibrations NC contact 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LR2K0308 . Santa Clara Systems carries 10,431 items from Telemecanique.
  • Tesys K - Differential Thermal Overload Relays - 1.8...2.6 - Class 10a

Alternates

    Common Typos

    • 1R2K0308
    • 1R2K030B
    • 1R2K03O8
    • 1R2K03OB
    • 1R2KO308
    • 1R2KO30B
    • 1R2KO3O8
    • 1R2KO3OB
    • 1RZK0308
    • 1RZK030B
    • 1RZK03O8
    • LR2K030B
    • LR2K03O8
    • LR2K03OB
    • LR2KO308
    • LR2KO30B
    • LR2KO3O8
    • LR2KO3OB
    • LRZK0308
    • LRZK030B
    • LRZK03O8
    • LRZK03OB
    • LRZKO308
    • LRZKO30B
    • LRZKO3O8
    • LRZKO3OB

    Appended Numbers

    • LR2K0308-A
    • LR2K0308-B
    • LR2K0308-C
    • LR2K0308-D
    • LR2K0308-E
    • LR2K0308-F
    • LR2K0308-G
    • LR2K0308-H
    • LR2K0308-I
    • LR2K0308-J
    • LR2K0308-K
    • LR2K0308-L
    • LR2K0308-M
    • LR2K0308-N
    • LR2K0308-O
    • LR2K0308-P
    • LR2K0308-Q
    • LR2K0308-R
    • LR2K0308-S
    • LR2K0308-T
    • LR2K0308-U
    • LR2K0308-V
    • LR2K0308-W
    • LR2K0308-X
    • LR2K0308-Y
    • LR2K0308-Z

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo