- Description: TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V DC coil
- Product weight: 1.06 lb(US) (0.48 kg)
- Range of product: TeSys D
- IP degree of protection: IP20 front face conforming to IEC 60529
- Standards: CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508
- Device short name: LC1D
- Width: 1.77 in (45 mm)
- Height: 3.03 in (77 mm)
- Depth: 3.74 in (95 mm)
- Protective treatment: TH conforming to IEC 60068-2-30
- [Ui] rated insulation voltage: 600 V power circuit certifications CSA600 V power circuit certifications UL690 V power circuit conforming to IEC 60947-4-1690 V signaling circuit conforming to IEC 60947-1600 V signaling circuit certifications CSA600 V signaling circuit certifications UL
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947
- Operating altitude: 9842.52 ft. (3000 m) without derating in temperature
- Mechanical durability: 30 Mcycles
- Tightening torque: Power circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mmPower circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2
- Connections - terminals: Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable endPower circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable endControl circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable endPower circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endPower circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endPower circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable endPower circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable endPower circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable end
- Range: TeSys
- Mounting support: PlateRail
- [Ith] conventional free air thermal current: 25 A at <= 140 °F (60 °C) power circuit10 A at <= 140 °F (60 °C) signaling circuit
- System Voltage: <= 300 V DC power circuit<= 690 V AC 25...400 Hz power circuit
- Operating rate: 3600 cyc/h at <= 140 °F (60 °C)
- Product name: TeSys D
- [Uc] control circuit voltage: 24 V DC
- Electrical durability: 0.6 Mcycles 25 A AC-1 at Ue <= 440 V2 Mcycles 9 A AC-3 at Ue <= 440 V
- Insulation resistance: > 10 MOhm signaling circuit
- motor power kW: 2.2 kW at 400 V AC 50/60 Hz AC-42.2 kW at 220...230 V AC 50/60 Hz AC-34 kW at 380...400 V AC 50/60 Hz AC-35.5 kW at 500 V AC 50/60 Hz AC-35.5 kW at 660...690 V AC 50/60 Hz AC-34 kW at 415...440 V AC 50/60 Hz AC-3
- [Ie] rated operational current: 25 A (<= 140 °F (60 °C)) at <= 440 V AC AC-1 power circuit9 A (<= 140 °F (60 °C)) at <= 440 V AC AC-3 power circuit
- Utilization category: AC-1AC-3AC-4
- Control circuit voltage limits: 0.1...0.3 Uc drop-out at 140 °F (60 °C), DC0.8...1.25 Uc operational at 140 °F (60 °C), DC
- Poles description: 3P
- Overvoltage category: III
- Operating time: 65.45...88.55 ms closing20...30 ms opening
- Associated fuse rating: 20 A gG at <= 690 V coordination type 2 power circuit25 A gG at <= 690 V coordination type 1 power circuit10 A gG signaling circuit conforming to IEC 60947-5-1
- Control circuit type: DC low consumption
- Coil technology: Built-in bidirectional peak limiting diode suppressor
- Time constant: 40 ms
- Pollution degree: 3
- Product or component type: Contactor
- inrush power in W: 2.4 W at 68 °F (20 °C)
- Ambient air temperature for operation: 23...140 °F (-5...60 °C)
- hold-in power consumption in W: 2.4 W at 68 °F (20 °C)
- Ambient air temperature for storage: -76...176 °F (-60...80 °C)
- Contactor application: Motor controlResistive load
- Auxiliary contacts type: Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1Type mirror contact (1 NC) conforming to IEC 60947-4-1
- Permissible ambient air temperature around the device: -40...158 °F (-40...70 °C) at Uc
- Signaling circuit frequency: 25...400 Hz
- Minimum switching current: 5 mA signaling circuit
- Fire resistance: 1562 °F (850 °C) conforming to IEC 60695-2-1
- Pole contact composition: 3 NO
- Minimum switching voltage: 17 V signaling circuit
- Flame retardance: V1 conforming to UL 94
- Non-overlap time: 1.5 ms on energisation between NC and NO contact1.5 ms on de-energisation between NC and NO contact
- Mechanical robustness: Vibrations contactor open 2 Gn, 5...300 HzVibrations contactor closed 4 Gn, 5...300 HzShocks contactor open 10 Gn for 11 msShocks contactor closed 15 Gn for 11 ms
- Power range: 1.1...2 kW 200...240 V 3 phases2.2...3 kW 380...440 V 3 phases4...6 kW 380...440 V 3 phases4...6 kW 480...500 V 3 phases
- Motor power hp: 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors1 hp at 230/240 V AC 50/60 Hz 1 phase motors2 hp at 200/208 V AC 50/60 Hz 3 phases motors2 hp at 230/240 V AC 50/60 Hz 3 phases motors5 hp at 460/480 V AC 50/60 Hz 3 phases motors7.5 hp at 575/600 V AC 50/60 Hz 3 phases motors
- Motor starter type: Direct on-line contactor
- Contactor coil voltage: 24 V DC low consumption
- Auxiliary contact composition: 1 NO + 1 NC
- Irms rated making capacity: 250 A at 440 V power circuit conforming to IEC 60947140 A AC signaling circuit conforming to IEC 60947-5-1250 A DC signaling circuit conforming to IEC 60947-5-1
- Rated breaking capacity: 250 A at 440 V power circuit conforming to IEC 60947
- [Icw] rated short-time withstand current: 105 A <= 104 °F (40 °C) 10 s power circuit210 A <= 104 °F (40 °C) 1 s power circuit30 A <= 104 °F (40 °C) 10 min power circuit61 A <= 104 °F (40 °C) 1 min power circuit100 A 1 s signaling circuit120 A 500 ms signaling circuit140 A 100 ms signaling circuit
- Average impedance: 2.5 mOhm at 50 Hz - Ith 25 A power circuit
- Power dissipation per pole: 0.2 W AC-31.56 W AC-1
- Protective cover: With
- Product certifications: DNVRINALROS (Lloyds register of shipping)BVULGLCSACCCGOST
- Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1D09BL . Santa Clara Systems carries 10,416 items from Telemecanique.
- Tesys D Contactor - 3p(3 No) - Ac-3 - <= 440 V 9 A - 24 V Dc Coil
Alternates
Common Typos
- LC1D0981
- LC1D098I
- LC1D098L
- LC1D09B1
- LC1D09BI
- LC1DO981
- LC1DO98I
- LC1DO98L
- LC1DO9B1
- LC1DO9BI
- LC1DO9BL
- LCID0981
- LCID098I
- LCID098L
- LCID09B1
- LCID09BI
- LCID09BL
- LCIDO981
- LCIDO98I
- LCIDO98L
- LCIDO9B1
- LCIDO9BI
- LCIDO9BL
- LCLD09B1
- LCLD09BI
- LCLD09BL
Appended Numbers
- LC1D09BL-A
- LC1D09BL-B
- LC1D09BL-C
- LC1D09BL-D
- LC1D09BL-E
- LC1D09BL-F
- LC1D09BL-G
- LC1D09BL-H
- LC1D09BL-I
- LC1D09BL-J
- LC1D09BL-K
- LC1D09BL-L
- LC1D09BL-M
- LC1D09BL-N
- LC1D09BL-O
- LC1D09BL-P
- LC1D09BL-Q
- LC1D09BL-R
- LC1D09BL-S
- LC1D09BL-T
- LC1D09BL-U
- LC1D09BL-V
- LC1D09BL-W
- LC1D09BL-X
- LC1D09BL-Y
- LC1D09BL-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier