• Telemecanique GV2 P20 TeSys GV2 - Motor circuit breaker - thermal-magnetic - 13?18 A Product Image
  • Telemecanique GV2 P20 TeSys GV2 - Motor circuit breaker - thermal-magnetic - 13?18 A Product Image
  • Telemecanique GV2 P20 TeSys GV2 - Motor circuit breaker - thermal-magnetic - 13?18 A Product Image
  • Telemecanique GV2 P20 TeSys GV2 - Motor circuit breaker - thermal-magnetic - 13?18 A Product Image
  • Telemecanique GV2 P20 Barcode

GV2P20

Get a Quote

Current response time:

By 5AM PT on Monday
  • Description: TeSys GV2 - Motor circuit breaker - thermal-magnetic - 13?18 A
  • IP degree of protection: IP20 conforming to IEC 60529
  • Standards: CSA C22.2, UL 508, NF C 63-650, IEC 60947-2, VDE 0113, IEC 60947-1, VDE 0660, NF C 63-120, EN 60204, NF C 79-130, IEC 60947-4-1
  • Device short name: GV2P
  • Width: 1.77 in (45 mm)
  • Height: 3.5 in (89 mm)
  • Depth: 3.82 in (97 mm)
  • Protective treatment: TH
  • [Ui] rated insulation voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
  • [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2
  • Operating altitude: 6561.68 ft. (2000 m)
  • Mechanical durability: 100000 cycles
  • Tightening torque: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals
  • Connections - terminals: Screw clamp terminals 2 cable(s) 0...0.01 in (1...6 mm) - cable stiffness : solid, Screw clamp terminals 2 cable(s) 0...0.01 in (1.5...6 mm) - cable stiffness : flexible - without cable end, Screw clamp terminals 2 cable(s) 0...0.01 in (1...4 mm) - cable stiffness : flexible - with cable end
  • Range: TeSys
  • Mounting support: Rail, Plate
  • [Ith] conventional free air thermal current: 18 A conforming to IEC 60947-4-1
  • System Voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
  • Operating rate: 25 cyc/h
  • Product name: TeSys GV2
  • Electrical durability: 100000 cycles AC-3 at 440 V
  • motor power kW: 15 kW at 690 V AC 50/60 Hz, 9 kW at 500 V AC 50/60 Hz, 7.5 kW at 400/415 V AC 50/60 Hz
  • Utilization category: AC-3 conforming to IEC 60947-4-1, Category A conforming to IEC 60947-2
  • Poles description: 3P
  • Control type: Rotary knob
  • Breaking capacity: 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2, 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 4 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
  • Mounting position: Vertical, Horizontal
  • Network type: AC
  • Product certifications: LROS (Lloyds register of shipping), CCC, BV, UL, CSA, RINA, ATEX, UL 508 type E, DNV, EAC, EZU, GL, TSE
  • Product or component type: Circuit breaker
  • Network frequency: 50/60 Hz conforming to IEC 60947-4-1
  • Device application: Motor
  • Mounting mode: By Clips / By Screws
  • IK degree of protection: IK04
  • Trip unit technology: Thermal-magnetic
  • Ambient air temperature for operation: -4...140 F (-20...60 C)
  • Ambient air temperature for storage: -40...176 F (-40...80 C)
  • Fire resistance: 1760 F (960 C) conforming to IEC 60695-2-1
  • [Ics] rated service short-circuit breaking capacity: 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2, 50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 75 % at 440 V AC 50/60 Hz conforming to IEC 60947-2, 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
  • [In] rated current: 13...18 A
  • Trip unit rating: 13...18 A
  • Magnetic tripping current: 223 A
  • Power dissipation per pole: 2.5 W
  • Rated duty: Continuous conforming to IEC 60947-4-1
  • Suitability for isolation: Yes conforming to IEC 60947-1
  • Phase failure sensitivity: Yes conforming to IEC 60947-4-1
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on GV2P20 . Santa Clara Systems carries 10,327 items from Telemecanique.
  • Tesys Gv2 - Motor Circuit Breaker - Thermal-Magnetic - 13?18 A

Alternates

  • GV2P20H7

Common Typos

  • 6V2P20
  • 6V2P2O
  • 6V2PZ0
  • 6V2PZO
  • 6VZP20
  • 6VZP2O
  • 6VZPZ0
  • 6VZPZO
  • GV2P2O
  • GV2PZ0
  • GV2PZO
  • GVZP20
  • GVZP2O
  • GVZPZ0
  • GVZPZO

Appended Numbers

  • GV2P20-A
  • GV2P20-B
  • GV2P20-C
  • GV2P20-D
  • GV2P20-E
  • GV2P20-F
  • GV2P20-G
  • GV2P20-H
  • GV2P20-I
  • GV2P20-J
  • GV2P20-K
  • GV2P20-L
  • GV2P20-M
  • GV2P20-N
  • GV2P20-O
  • GV2P20-P
  • GV2P20-Q
  • GV2P20-R
  • GV2P20-S
  • GV2P20-T
  • GV2P20-U
  • GV2P20-V
  • GV2P20-W
  • GV2P20-X
  • GV2P20-Y
  • GV2P20-Z

More Products Like This

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo