- Description: current control relay RM35-J - range 0.15..1.5 A
- Product weight: 0.29 lb(US) (0.13 kg)
- Range of product: Zelio Control
- IP degree of protection: IP20(terminals) conforming to IEC 60529, IP30 (casing) conforming to IEC 60529
- Standards: EN/IEC 60255-6
- Width: 1.38 in (35 mm)
- [Ui] rated insulation voltage: 250 V conforming to IEC 60664-1
- Mechanical durability: 30000000 cycles
- Tightening torque: 5.31...8.85 lbf.in (0.6...1 N.m) conforming to IEC 60947-1
- Connections - terminals: Screw terminals 1 x 0.5...1 x 4 mm - AWG 20...AWG 11, solid cable without cable end, Screw terminals 2 x 0.5...2 x 2.5 mm - AWG 20...AWG 14, solid cable without cable end, Screw terminals 1 x 0.2...1 x 2.5 mm - AWG 24...AWG 12, flexible cable with cable end, Screw terminals 2 x 0.2...2 x 1.5 mm - AWG 24...AWG 16, flexible cable with cable end
- Mounting support: 35 mm symmetrical DIN rail conforming to EN/IEC 60715
- Operating rate: <= 360 operations/hour under full load
- Vibration resistance: 0.35 mm (f = 5...57.6 Hz) conforming to IEC 60068-2-6, 1 gn (f = 57.6...150 Hz) conforming to IEC 60255-21-1
- Shock resistance: 15 gn 11 ms conforming to IEC 60255-21-1
- Electrical durability: 100000 cycles
- Insulation resistance: > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5, > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1, > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5, > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1, > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5, > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1
- Utilization category: AC-12 conforming to IEC 60947-5-1, AC-13 conforming to IEC 60947-5-1, AC-14 conforming to IEC 60947-5-1, AC-15 conforming to IEC 60947-5-1, DC-12 conforming to IEC 60947-5-1, DC-13 conforming to IEC 60947-5-1, DC-14 conforming to IEC 60947-5-1
- Control circuit voltage limits: - 15 % + 10 % Un
- [Us] rated supply voltage: 24...240 V AC/DC, 50/60 Hz +/- 10 %
- Overvoltage category: III conforming to IEC 60664-1
- Relative humidity: 95 % at 131 F (55 C) conforming to IEC 60068-2-30
- Housing material: Self-extinguishing plastic
- Dielectric test voltage: 2 kV AC 50 Hz, 1 min conforming to IEC 60255-5, 2 kV AC 50 Hz, 1 min conforming to IEC 60664-1
- Reset time: 1500 ms time delay
- Immunity to micro breaks: 50 ms
- Product or component type: Modular measurement and control relays
- Maximum switching voltage: 250 V AC/DC
- Electromagnetic compatibility: Emission standard for industrial environments conforming to EN/IEC 61000-6-4, Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3, Immunity for industrial environments conforming to NF EN/IEC 61000-6-2
- Relay type: Current control relay
- Relay name: RM35JA
- Supply voltage limits: 20.4...264 V AC/DC
- Product certifications: C-Tick, GL, UL, GOST, CSA
- Relay monitored parameters: Overcurrent or undercurrent detection
- Ambient air temperature for storage: -40...158 F (-40...70 C)
- Time delay type: Adjustable 1...20 s, 0 + 10 % on energisation Ti, Adjustable 0.3...30 s, 0 + 10 % on crossing the threshold Tt
- power consumption in W: <= 0.6 W DC
- Ambient air temperature for operation: -4...122 F (-20...50 C)
- switching capacity in VA: 1250 VA
- Control circuit frequency: 40...70 Hz +/- 10 %
- Minimum switching current: 10 mA at 5 V DC
- Resistance across terminals: 0.005 Ohm E3-M terminals, 0.015 Ohm E2-M terminals, 0.05 Ohm E1-M terminals
- Maximum switching current: 5 A AC/DC
- Output contacts: 2 C/O
- power consumption in VA: <= 3.5 VA AC
- Nominal output current: 5:00 AM
- Measurement range: 0.15...1.5 A E1-M terminals, 0.5...5 A E2-M terminals, 1.5...15 A E3-M terminals, 150 mA...15 A current
- Measuring cycle: <= 30 ms measurement cycle as true rms value
- Pollution degree: 3 conforming to IEC 60664-1
- Hysteresis: 5...50 % of threshold setting
- Run-up delay at power-up: 0.3 s
- Non-dissipating shock wave: 4 kV conforming to IEC 60255-5, 4 kV conforming to IEC 60664-1, 4 kV conforming to IEC 61000-4-5
- Measurement accuracy: +/- 10 % of the full scale value
- Repeat accuracy: +/- 0.5 % input and measurement circuit, +/- 2 % time delay
- Measurement error: 0.05 %/C with temperature variation, 1 by volt over the whole range with voltage variation
- Polarity: No DC
- Threshold setting: 10...100 %
- Marking: CE : EMC 89/336/EEC, CE : 73/23/EEC
- Operating position: Any position without derating
- Local signaling: LED green power ON, LED yellow relay ON
- Safety reliability data: MTTFd = 296.8 years, B10d = 270000
- Contacts material: Cadmium free
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on RM35JA32MW . Santa Clara Systems carries 10,327 items from Telemecanique.
- Current Control Relay Rm35-J - Range 0.15..1.5 A
Alternates
Common Typos
- RM35JA3ZMW
- RM3SJA32MW
- RM3SJA3ZMW
Appended Numbers
- RM35JA32MW-A
- RM35JA32MW-B
- RM35JA32MW-C
- RM35JA32MW-D
- RM35JA32MW-E
- RM35JA32MW-F
- RM35JA32MW-G
- RM35JA32MW-H
- RM35JA32MW-I
- RM35JA32MW-J
- RM35JA32MW-K
- RM35JA32MW-L
- RM35JA32MW-M
- RM35JA32MW-N
- RM35JA32MW-O
- RM35JA32MW-P
- RM35JA32MW-Q
- RM35JA32MW-R
- RM35JA32MW-S
- RM35JA32MW-T
- RM35JA32MW-U
- RM35JA32MW-V
- RM35JA32MW-W
- RM35JA32MW-X
- RM35JA32MW-Y
- RM35JA32MW-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier