- Description: TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 220...230 V AC coil
- Range of product: TeSys K
- Protective treatment: TC conforming to IEC 60068TC conforming to DIN 50016
- Operating altitude: 6561.68 ft. (2000 m) without derating in temperature
- Range: TeSys
- [Ith] conventional free air thermal current: 20 A at <= 122 °F (50 °C) power circuit10 A at <= 122 °F (50 °C) signaling circuit
- Operating rate: 3600 cyc/h
- Product name: TeSys K
- [Uc] control circuit voltage: 220...230 V AC 50/60 Hz
- Insulation resistance: > 10 MOhm signaling circuit
- motor power kW: 2.2 kW at 400 V AC 50/60 Hz AC-42.2 kW at 220...230 V AC 50/60 Hz AC-34 kW at 380...415 V AC 50/60 Hz AC-34 kW at 440 V AC 50/60 Hz AC-34 kW at 480 V AC 50/60 Hz AC-34 kW at 500...600 V AC 50/60 Hz AC-34 kW at 660...690 V AC 50/60 Hz AC-3
- [Ie] rated operational current: 9 A at <= 440 V AC AC-3 power circuit20 A (<= 122 °F (50 °C)) at <= 440 V AC AC-1 power circuit16 A (<= 158 °F (70 °C)) at 690 V AC AC-1 power circuit
- Utilization category: AC-1AC-3AC-4
- Control circuit voltage limits: 0.2...0.75 Uc at <= 122 °F (50 °C) drop-out0.8...1.15 Uc at <= 122 °F (50 °C) operational
- Poles description: 3P
- Overvoltage category: III
- Operating time: 10...20 ms coil de-energisation and NO opening10...20 ms coil energisation and NO closing
- Associated fuse rating: 25 A gG at <= 440 V power circuit25 A aM power circuit10 A gG signaling circuit conforming to IEC 6094710 A gG signaling circuit conforming to VDE 0660
- Control circuit type: AC 50/60 Hz
- Product certifications: CSAUL
- Product or component type: Contactor
- Pole contact composition: 3 NO
- Flame retardance: V1 conforming to UL 94Requirement 2 conforming to NF F 16-101Requirement 2 conforming to NF F 16-102
- Device application: Control
- Contactor application: Motor controlResistive load
- Auxiliary contact composition: 1 NO
- Irms rated making capacity: 110 A AC power circuit conforming to NF C 63-110110 A AC power circuit conforming to IEC 60947110 A AC signaling circuit conforming to IEC 60947
- Rated breaking capacity: 110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 60947110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947
- Average impedance: 3 mOhm at 50 Hz - Ith 20 A power circuit
- inrush power in VA: 30 VA at 68 °F (20 °C)
- hold-in power consumption in VA: 4.5 VA at 68 °F (20 °C)
- Heat dissipation: 1.3 W
- Auxiliary contacts type: Type instantaneous (1 NO)
- Signaling circuit frequency: <= 400 Hz
- Minimum switching current: 5 mA signaling circuit
- Minimum switching voltage: 17 V signaling circuit
- Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
- Non overlap distance: 0.02 in (0.5 mm)
- Mechanical robustness: Shocks contactor closed, on X axis 10 Gn for 11 ms IEC 60068-2-27Shocks contactor closed, on Y axis 15 Gn for 11 ms IEC 60068-2-27Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27Shocks contactor opened, on X axis 6 Gn for 11 ms IEC 60068-2-27Shocks contactor opened, on Y axis 10 Gn for 11 ms IEC 60068-2-27Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6Vibrations contactor opened 2 Gn, 5...300 Hz IEC 60068-2-6
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1K0910M7 . Santa Clara Systems carries 10,416 items from Telemecanique.
- Tesys K Contactor - 3p - Ac-3 <= 440 V 9 A - 1 No Aux. - 220...230 V Ac Coil
Alternates
Common Typos
- LC1K091OM7
- LC1K09I0M7
- LC1K09IOM7
- LC1K09L0M7
- LC1K09LOM7
- LC1KO910M7
- LC1KO91OM7
- LC1KO9I0M7
- LC1KO9IOM7
- LC1KO9L0M7
- LC1KO9LOM7
- LCIK0910M7
- LCIK091OM7
- LCIK09I0M7
- LCIK09IOM7
- LCIK09L0M7
- LCIK09LOM7
- LCIKO910M7
- LCIKO91OM7
- LCIKO9I0M7
- LCIKO9IOM7
- LCIKO9L0M7
- LCIKO9LOM7
- LCLK0910M7
- LCLK091OM7
- LCLK09I0M7
Appended Numbers
- LC1K0910M7-A
- LC1K0910M7-B
- LC1K0910M7-C
- LC1K0910M7-D
- LC1K0910M7-E
- LC1K0910M7-F
- LC1K0910M7-G
- LC1K0910M7-H
- LC1K0910M7-I
- LC1K0910M7-J
- LC1K0910M7-K
- LC1K0910M7-L
- LC1K0910M7-M
- LC1K0910M7-N
- LC1K0910M7-O
- LC1K0910M7-P
- LC1K0910M7-Q
- LC1K0910M7-R
- LC1K0910M7-S
- LC1K0910M7-T
- LC1K0910M7-U
- LC1K0910M7-V
- LC1K0910M7-W
- LC1K0910M7-X
- LC1K0910M7-Y
- LC1K0910M7-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier