- Description: TeSys GV2 - Circuit breaker - thermal-magnetic - 17...23 A - spring terminals
- Product weight: 0.62 lb(US) (0.28 kg)
- IP degree of protection: IP20 conforming to IEC 60529
- Standards: NF C 63-650, UL 508, VDE 0113, IEC 60947-2, EN 60204, IEC 60947-4-1, CSA C22.2, NF C 63-120, IEC 60947-1, VDE 0660, NF C 79-130
- Device short name: GV2ME
- Width: 1.77 in (45 mm)
- Height: 3.98 in (101 mm)
- Depth: 3.08 in (78.2 mm)
- Protective treatment: TH
- [Ui] rated insulation voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2
- Operating altitude: 6561.68 ft. (2000 m)
- Mechanical durability: 100000 cycles
- Connections - terminals: Spring terminals 2 cable(s) 0...0.01 in (1...6 mm) - cable stiffness : solid, Spring terminals 2 cable(s) 0...0.01 in (1.5...4 mm) - cable stiffness : flexible - without cable end
- Range: TeSys
- Mounting support: Rail
- [Ith] conventional free air thermal current: 23 A conforming to IEC 60947-4-1
- System Voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
- Operating rate: 25 cyc/h
- Product name: TeSys GV2
- Electrical durability: 100000 cycles AC-3 at 440 V
- motor power kW: 11 kW at 400/415 V AC 50/60 Hz, 11 kW at 500 V AC 50/60 Hz, 9 kW at 400/415 V AC 50/60 Hz
- Utilization category: AC-3 conforming to IEC 60947-4-1, Category A conforming to IEC 60947-2
- Poles description: 3P
- Control type: Push-button
- Breaking capacity: 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2, 15 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 50 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 6 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2, 4 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
- Mounting position: Horizontal, Vertical
- Network type: AC
- Product certifications: BV, ATEX, GL, DNV, LROS (Lloyds register of shipping), EAC, EZU, UL, RINA, CEBEC, CCC, TSE, SETI, CSA
- Product or component type: Circuit breaker
- Network frequency: 50/60 Hz conforming to IEC 60947-4-1
- Device application: Motor
- Mounting mode: By Clips / By Screws
- IK degree of protection: IK04
- Trip unit technology: Thermal-magnetic
- Ambient air temperature for operation: -4...140 F (-20...60 C)
- Ambient air temperature for storage: -40...176 F (-40...80 C)
- Fire resistance: 1760 F (960 C) conforming to IEC 60695-2-1
- [Ics] rated service short-circuit breaking capacity: 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2, 40 %at 400/415 V AC 50/60 Hz conforming to IEC 60947-2, 50 %at 440 V AC 50/60 Hz conforming to IEC 60947-2, 75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2, 75 %at 690 V AC 50/60 Hz conforming to IEC 60947-2
- [In] rated current: 17...23 A
- Trip unit rating: 17...23 A
- Magnetic tripping current: 327 A
- Power dissipation per pole: 2.5 W
- Rated duty: Continuous conforming to IEC 60947-4-1
- Suitability for isolation: Yes conforming to IEC 60947-1
- Phase failure sensitivity: Yes conforming to IEC 60947-4-1
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on GV2ME213 . Santa Clara Systems carries 10,327 items from Telemecanique.
- Tesys Gv2 - Circuit Breaker - Thermal-Magnetic - 17...23 A - Spring Terminals
Alternates
Common Typos
- 6V2ME213
- 6V2ME2I3
- 6V2ME2L3
- 6V2MEZ13
- 6V2MEZI3
- 6V2MEZL3
- 6VZME213
- 6VZME2I3
- 6VZME2L3
- 6VZMEZ13
- 6VZMEZI3
- 6VZMEZL3
- GV2ME2I3
- GV2ME2L3
- GV2MEZ13
- GV2MEZI3
- GV2MEZL3
- GVZME213
- GVZME2I3
- GVZME2L3
- GVZMEZ13
- GVZMEZI3
- GVZMEZL3
Appended Numbers
- GV2ME213-A
- GV2ME213-B
- GV2ME213-C
- GV2ME213-D
- GV2ME213-E
- GV2ME213-F
- GV2ME213-G
- GV2ME213-H
- GV2ME213-I
- GV2ME213-J
- GV2ME213-K
- GV2ME213-L
- GV2ME213-M
- GV2ME213-N
- GV2ME213-O
- GV2ME213-P
- GV2ME213-Q
- GV2ME213-R
- GV2ME213-S
- GV2ME213-T
- GV2ME213-U
- GV2ME213-V
- GV2ME213-W
- GV2ME213-X
- GV2ME213-Y
- GV2ME213-Z
More Products Like This
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier