• Telemecanique XPSCM1144P Barcode

XPSCM1144P

Get a Quote

Current response time:

By 5AM PT on Monday
  • Description: module XPS-CM - single-beam photo-electric sensors - 24 V DC
  • Range of product: Preventa Safety detection
  • IP degree of protection: IP20(terminals) conforming to IEC 60529IP40(enclosure) conforming to IEC 60529
  • [Ui] rated insulation voltage: 300 V, degree of pollution 2 conforming to EN/IEC 60947-5-1300 V, degree of pollution 2 conforming to DIN VDE 0110 parts 1 and 2
  • [Uimp] rated impulse withstand voltage: 4 kV overvoltage category III, conforming to EN/IEC 60947-5-14 kV overvoltage category III, conforming to DIN VDE 0110 parts 1 and 2
  • Connections - terminals: Captive screw clamp terminals, removable terminal block, clamping capacity: 1 x 0.25...1 x 2.5 mm² flexible cable with cable end, without bezelCaptive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.2...2 x 1 mm² solid cable without cable endCaptive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.25...2 x 1 mm² flexible cable with cable end, without bezelCaptive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.5...2 x 1.5 mm² flexible cable with cable end, with double bezelCaptive screw clamp terminals, removable terminal block, clamping capacity: 1 x 0.2...1 x 2.5 mm² solid or flexible cable without cable endCaptive screw clamp terminals, removable terminal block, clamping capacity: 1 x 0.25...1 x 2.5 mm² flexible cable with cable end, with bezelCaptive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.2...2 x 1.5 mm² flexible cable without cable end
  • [Us] rated supply voltage: 24 V DC (- 20...20 %)
  • Associated fuse rating: 4 A gG for relay output conforming to DIN VDE 0660 part 2004 A gG for relay output conforming to EN/IEC 60947-5-16 A fast blow for relay output conforming to DIN VDE 0660 part 2006 A fast blow for relay output conforming to EN/IEC 60947-5-1
  • Protection type: Electronic internal fuse
  • Breaking capacity: 1.5 A/24 V - L/R = 50 ms, DC-13 relay output20 mA/24 V for solid state output
  • Output type: Relay 2 NO (13-14, 23-24), volt-free
  • Input voltage: 24 V DC (terminal(s) U+, U-) muting function24 V DC sensor
  • Sensor power supply: 24 V DC (terminal(s) U+, U-)
  • Ambient air temperature for operation: 14...131 °F (-10...55 °C)
  • Product or component type: Safety module
  • Supply current for sensors: < 200 mA
  • Ambient air temperature for storage: -13...185 °F (-25...85 °C)
  • Safety module name: XPSCM
  • Input current: < 200 mA for muting function
  • Safety module application: For monitoring of single beam photo-electric sensor
  • Synchronisation time between inputs: 3 s (+/- 20 %) for the activation of the MA/MB muting signal
  • Function of module: Built-in muting
  • Muting maximum duration: 60 s (- 10...30 %)
  • Safety level: Can reach category 2 conforming to EN/ISO 13849-1 with the appropriate control system and correctly wiredCan reach SILCL 1 conforming to EN/IEC 62061 with the appropriate control system and correctly wiredCan reach PL = c conforming to EN/ISO 13849-1 with the appropriate control system and correctly wired
  • Line resistance: <= 10 Ohm for sensor power supply
  • Safety reliability data: MTTFd = 16.6 years conforming to EN/ISO 13849-1DC = 95.5 % conforming to EN/ISO 13849-1PFH = 3.12E-7 1/h conforming to EN/IEC 61508PFHd = 3.12E-7 1/h conforming to EN/IEC 62061
  • Number of inputs: 2 (terminal(s) MA, MB) muting function4 (terminal(s) Z1, Z2, Z3, Z4) sensor
  • Input compatibility: XC limit switch muting functionXU2M18PP340... muting functionXU2S18PP340... (infrared) sensorXU9M18PP340... muting function
  • Minimum output current: 10 mA relay output
  • Minimum output voltage: 17 V relay output
  • Response time on input open: <= 25 ms
  • Number of additional circuits: 0
  • Local signalling: 1 LED, function electronic internal fuse status1 LED, function restarting1 LED, function safety outputs closed1 LED, function safety outputs open1 incandescent lamp, function muting power consumption: 4...6.5 W
  • Output thermal current: 5.6 A per relay11 A maximum
  • power consumption in W: <= 15 W
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on XPSCM1144P . Santa Clara Systems carries 10,416 items from Telemecanique.
  • Module Xps-Cm - Single-Beam Photo-Electric Sensors - 24 V Dc

Alternates

    Common Typos

    • XP5CM1144P
    • XP5CM1I44P
    • XP5CM1L44P
    • XP5CMI144P
    • XP5CMII44P
    • XP5CMIL44P
    • XP5CML144P
    • XP5CMLI44P
    • XP5CMLL44P
    • XPSCM1I44P
    • XPSCM1L44P
    • XPSCMI144P
    • XPSCMII44P
    • XPSCMIL44P
    • XPSCML144P
    • XPSCMLI44P
    • XPSCMLL44P

    Appended Numbers

    • XPSCM1144P-A
    • XPSCM1144P-B
    • XPSCM1144P-C
    • XPSCM1144P-D
    • XPSCM1144P-E
    • XPSCM1144P-F
    • XPSCM1144P-G
    • XPSCM1144P-H
    • XPSCM1144P-I
    • XPSCM1144P-J
    • XPSCM1144P-K
    • XPSCM1144P-L
    • XPSCM1144P-M
    • XPSCM1144P-N
    • XPSCM1144P-O
    • XPSCM1144P-P
    • XPSCM1144P-Q
    • XPSCM1144P-R
    • XPSCM1144P-S
    • XPSCM1144P-T
    • XPSCM1144P-U
    • XPSCM1144P-V
    • XPSCM1144P-W
    • XPSCM1144P-X
    • XPSCM1144P-Y
    • XPSCM1144P-Z

    More Products Like This

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo