  • Description: multifunction control unit LUCM - class 5...30 - 3...12 A - 24 V DC
  • Product weight: 0.39 lb(US) (0.175 kg)
  • IP degree of protection: IP20 front panel and wired terminals conforming to IEC 60947-1, IP20 other faces conforming to IEC 60947-1, IP40 front panel outside connection zone conforming to IEC 60947-1
  • Standards: CSA C22.2 No 14 type E, EN 60947-6-2, IEC 60947-6-2, UL 508 type E with phase barrier
  • Device short name: LUCM
  • Protective treatment: TH conforming to IEC 60068
  • [Ui] rated insulation voltage: 600 V conforming to CSA C22.2 No 14, 600 V conforming to UL 508, 690 V conforming to IEC 60947-1
  • [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-6-2
  • Operating altitude: 6561.68 ft. (2000 m)
  • Range: TeSys
  • Product name: TeSys U
  • [Uc] control circuit voltage: 24 V DC
  • Shock resistance: 10 gn power poles open conforming to IEC 60068-2-27, 15 gn power poles closed conforming to IEC 60068-2-27
  • Vibration resistance: 2 gn 5...300 Hz power poles open conforming to IEC 60068-2-6, 4 gn 5...300 Hz power poles closed conforming to IEC 60068-2-6
  • motor power kW: 9 kW at 690 V AC 50/60 Hz, 5.5 kW at 400...440 V AC 50/60 Hz, 5.5 kW at 500 V AC 50/60 Hz
  • Utilization category: AC-44, AC-41, AC-43
  • Control circuit voltage limits: 20...28 V DC circuit 24 V in operation
  • Operating time: 35 ms opening with LUB12 control circuit, 35 ms opening with LUB32 control circuit, 65 ms closing with LUB32 control circuit, 75 ms closing with LUB12 control circuit
  • Function available: Log function, Monitoring function, indication of main motor parameters, Protection function alarm, Overload, no-load running, Differentiation of thermal overload and magnetic fault, Earth fault protection, Protection against overload and short-circuit, Protection against phase failure and phase imbalance, Manual or automatic reset
  • Heat dissipation: 0.8 W external auxiliary circuit, 1.7 W control circuit with LUB12, 1.8 W control circuit with LUB32
  • Mounting mode: Plug-in
  • Immunity to micro breaks: 3 ms
  • Mounting location: Front side
  • Immunity to voltage dips: 70 % 500 ms conforming to IEC 61000-4-11
  • Product or component type: Multifunction control unit
  • Product specific application: Most sophisticated control and protection requirements, with display
  • Typical current consumption: 150 mA at 24 V DC I maximum while closing with LUB12, 200 mA at 24 V DC I maximum while closing with LUB32, 70 mA at 24 V DC I rms sealed with LUB12, 75 mA at 24 V DC I rms sealed
  • Product certifications: CSA, BV, ABS, CCC, ASEFA, GL, ATEX, GOST, DNV, UL, LROS (Lloyds register of shipping)
  • Product compatibility: ASILUFC51, LUFC00, LULC031, ASILUFC5, LUFV2, LULC08, LULC07, LUFN.., LULC033, LULC09, LULC15
  • Load type: Single-phase motor - cooling: self-cooled, force cooled - setting settable, 3-phase motor - cooling: self-cooled, force cooled - setting settable
  • Tripping threshold: 14.2 x Ir +/- 20 %
  • Ambient air temperature for operation: -13...140 F (-25...60 C)
  • Thermal protection adjustment range: 3...12 A
  • Physical interface: RS485 multidrop - connector(s): RJ45 - location: front panel - communication protocol: Modbus RTU 19200 bit/s
  • Ambient air temperature for storage: -40...185 F (-40...85 C)
  • Return time: <= 200 ms
  • Thermal overload class: Class 5?30 - frequency limit: 50...60 Hz - temperature compensation: -13...131 F (-25...55 C) - conforming to IEC 60947-6-2, Class 5?30 - frequency limit: 50...60 Hz - temperature compensation: -13...131 F (-25...55 C) - conforming to UL 508
  • Messages display capacity: 2 lines of 12 characters - display LCD - English - accuracy +/- 5 % - resolution 1 % of Ir, 2 lines of 12 characters - display LCD - French - accuracy +/- 5 % - resolution 1 % of Ir, 2 lines of 12 characters - display LCD - German - accuracy +/- 5 % - resolution 1 % of Ir, 2 lines of 12 characters - display LCD - Italian - accuracy +/- 5 % - resolution 1 % of Ir, 2 lines of 12 characters - display LCD - Spanish - accuracy +/- 5 % - resolution 1 % of Ir
  • Fire resistance: 1202 F (650 C) conforming to IEC 60695-2-12, 1760 F (960 C) parts supporting live components conforming to IEC 60695-2-12
  • User language: English - setting factory setting, English, French, German, Italian, Spanish - setting settable
  • Reset: Automatic reset - setting: setting range, Manual - setting: factory setting, Manual - setting: setting range, Remote reset - setting: setting range
  • Time before reset: 120 s - reset manual - setting factory setting, 1...1000 s - reset manual or automatic reset - setting settable
  • Information displayed: Average current - setting factory setting, Average current - setting settable, Cause of last 5 faults - setting settable, Current in phase - setting settable, Earth leakage current - setting settable, Phase imbalance - setting settable, Thermal state of motor - setting settable
  • Resistance to electrostatic discharge: 8 kV level 3 in open air conforming to IEC 61000-4-2, 8 kV level 4 on contact conforming to IEC 61000-4-2
  • Resistance to radiated fields: 9.14 V/yd (10 V/m) 3 conforming to IEC 61000-4-3
  • Resistance to fast transients: 2 kV class 3 serial link conforming to IEC 61000-4-4, 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
  • Safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
  • Immunity to radio electric fields: 10 V conforming to IEC 61000-4-6
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LUCM12BL . Santa Clara Systems carries 10,416 items from Telemecanique.
  • Multifunction Control Unit Lucm - Class 5...30 - 3...12 A - 24 V Dc

Alternates

    Common Typos

    • LUCM1281
    • LUCM128I
    • LUCM128L
    • LUCM12B1
    • LUCM12BI
    • LUCM1Z81
    • LUCM1Z8I
    • LUCM1Z8L
    • LUCM1ZB1
    • LUCM1ZBI
    • LUCM1ZBL
    • LUCMI281
    • LUCMI28I
    • LUCMI28L
    • LUCMI2B1
    • LUCMI2BI
    • LUCMI2BL
    • LUCMIZ81
    • LUCMIZ8I
    • LUCMIZ8L
    • LUCMIZB1
    • LUCMIZBI
    • LUCMIZBL
    • LUCML2B1
    • LUCML2BI
    • LUCML2BL

    Appended Numbers

    • LUCM12BL-A
    • LUCM12BL-B
    • LUCM12BL-C
    • LUCM12BL-D
    • LUCM12BL-E
    • LUCM12BL-F
    • LUCM12BL-G
    • LUCM12BL-H
    • LUCM12BL-I
    • LUCM12BL-J
    • LUCM12BL-K
    • LUCM12BL-L
    • LUCM12BL-M
    • LUCM12BL-N
    • LUCM12BL-O
    • LUCM12BL-P
    • LUCM12BL-Q
    • LUCM12BL-R
    • LUCM12BL-S
    • LUCM12BL-T
    • LUCM12BL-U
    • LUCM12BL-V
    • LUCM12BL-W
    • LUCM12BL-X
    • LUCM12BL-Y
    • LUCM12BL-Z

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo