- Description: power base - TeSys U - 12 A - 24 V DC screw clamps control
- Product weight: 2.8 lb(US) (1.27 kg)
- IP degree of protection: IP20 front panel and wired terminals conforming to IEC 60947-1IP20 other faces conforming to IEC 60947-1IP40 front panel outside connection zone conforming to IEC 60947-1
- Standards: CSA C22.2 No 14 type EEN 60947-6-2IEC 60947-6-2UL 508 type E with phase barrier
- Device short name: LU2B
- Width: 1.77 in (45 mm)
- Height: 8.82 in (224 mm)
- Depth: 4.96 in (126 mm)
- Protective treatment: TH conforming to IEC 60068
- [Ui] rated insulation voltage: 600 V conforming to CSA C22.2 No 14600 V conforming to UL 508690 V conforming to IEC 60947-1 3
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-6-2
- Operating altitude: 6561.68 ft. (2000 m)
- Mechanical durability: 15000000 cycles
- Tightening torque: Control circuit: 7.08...10.62 lbf.in (0.8...1.2 N.m) - with screwdriver 0.2 in (5 mm) flatControl circuit: 7.08...10.62 lbf.in (0.8...1.2 N.m) - with screwdriver 0.2 in (5 mm) Philips no 1Power circuit: 16.81...22.12 lbf.in (1.9...2.5 N.m) - with screwdriver 0.24 in (6 mm) flatPower circuit: 16.81...22.12 lbf.in (1.9...2.5 N.m) - with screwdriver 0.24 in (6 mm) Philips No 2
- Connections - terminals: Power circuit: screw clamp terminals 2 cable 0...0.01 in² (1.5...6 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 1 cable 0...0 in² (0.34...1.5 mm²) - cable stiffness: flexible - with cable endControl circuit: screw clamp terminals 1 cable 0...0 in² (0.75...1.5 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 1 cable 0...0 in² (0.75...1.5 mm²) - cable stiffness: rigid - without cable endControl circuit: screw clamp terminals 2 cable 0...0 in² (0.34...1.5 mm²) - cable stiffness: flexible - with cable endControl circuit: screw clamp terminals 2 cable 0...0 in² (0.75...1.5 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 2 cable 0...0 in² (0.75...1.5 mm²) - cable stiffness: rigid - without cable endPower circuit: screw clamp terminals 1 cable 0...0.02 in² (1...10 mm²) - cable stiffness: rigid - without cable endPower circuit: screw clamp terminals 1 cable 0...0.01 in² (1...6 mm²) - cable stiffness: flexible - with cable endPower circuit: screw clamp terminals 1 cable 0...0.02 in² (2.5...10 mm²) - cable stiffness: flexible - without cable endPower circuit: screw clamp terminals 2 cable 0...0.01 in² (1...6 mm²) - cable stiffness: flexible - with cable endPower circuit: screw clamp terminals 2 cable 0...0.01 in² (1...6 mm²) - cable stiffness: rigid - without cable end
- Range: TeSys
- [Ith] conventional free air thermal current: 12:00 AM
- System Voltage: 230 V440 V500 V690 V
- Operating rate: 60 cyc/mn
- Product name: TeSys U
- [Uc] control circuit voltage: 24 V DC
- Shock resistance: 10 gn power poles open conforming to IEC 60068-2-2715 gn power poles closed conforming to IEC 60068-2-27
- Vibration resistance: 2 gn 5...300 Hz power poles open conforming to IEC 60068-2-274 gn 5...300 Hz power poles closed conforming to IEC 60068-2-27
- [Ie] rated operational current: 12 A at <= 440 V12 A at 500 V9 A at 690 V
- Utilization category: AC-44AC-41AC-43
- Control circuit voltage limits: 14.5 V 24 V DC drop-out20...27 V 24 V DC in operation
- Poles description: 3P
- Operating time: 150 ms with change of direction power circuit35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM control circuit70 ms closing with LUCA, LUCB, LUCC, LUCD control circuit75 ms closing with LUCM control circuit75 ms without change of direction power circuit
- Auxiliary contact composition: 1 NO + 1 NC
- Heat dissipation: 2 W for control circuit with LUCA, LUCB, LUCC, LUCD1.7 W for control circuit with LUCM
- Auxiliary contacts type: Type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1Type mirror contact (1 NC) state of the power conforming to draft IEC 60947-1
- Immunity to micro breaks: 3 ms
- Immunity to voltage dips: 70 % 500 ms conforming to IEC 61000-4-11
- Product or component type: Reversing power base
- Network frequency: 40...60 Hz
- Product certifications: BVCSAABSGOSTGLULCCCLROS (Lloyds register of shipping)ASEFADNVATEX
- Device application: Motor
- [Ics] rated service breaking capacity: 10 kA 500 V4 kA 690 V50 kA 230 V50 kA 440 V
- Suitability for isolation: Yes
- Typical current consumption: 120 mA at 24 V DC I maximum while closing120 mA at 24 V DC I rms sealed
- Ambient air temperature for operation: -13...140 °F (-25...60 °C) with LUCM-13...158 °F (-25...70 °C) with LUCA, LUCB, LUCC, LUCD
- Inrush restraint duration: 15 ms DC network
- Ambient air temperature for storage: -40...185 °F (-40...85 °C)
- Safety reliability level: B10d 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
- Fire resistance: 1202 °F (650 °C) conforming to IEC 60695-2-121760 °F (960 °C) parts supporting live components conforming to IEC 60695-2-12
- Resistance to electrostatic discharge: 8 kV level 3 in open air conforming to IEC 61000-4-28 kV level 4 on contact conforming to IEC 61000-4-2
- Resistance to radiated fields: 9.14 V/yd (10 V/m) 3 conforming to IEC 61000-4-3
- Safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
- Resistance to fast transients: 2 kV class 3 serial link conforming to IEC 61000-4-44 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
- Non-dissipating shock wave: 0 kV 24 V DC1 kV serial mode 48...220 V DC conforming to IEC 60947-6-22 kV common mode 24...240 V AC conforming to IEC 60947-6-2
- Immunity to radio electric fields: 10 V conforming to IEC 61000-4-6
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LU2B12BL . Santa Clara Systems carries 10,416 items from Telemecanique.
- Power Base - Tesys U - 12 A - 24 V Dc Screw Clamps Control
Alternates
Common Typos
- LU2B1281
- LU2B128I
- LU2B128L
- LU2B12B1
- LU2B12BI
- LU2B1Z81
- LU2B1Z8I
- LU2B1Z8L
- LU2B1ZB1
- LU2B1ZBI
- LU2B1ZBL
- LU2BI281
- LU2BI28I
- LU2BI28L
- LU2BI2B1
- LU2BI2BI
- LU2BI2BL
- LU2BIZ81
- LU2BIZ8I
- LU2BIZ8L
- LU2BIZB1
- LU2BIZBI
- LU2BIZBL
- LU2BL2B1
- LU2BL2BI
- LU2BL2BL
Appended Numbers
- LU2B12BL-A
- LU2B12BL-B
- LU2B12BL-C
- LU2B12BL-D
- LU2B12BL-E
- LU2B12BL-F
- LU2B12BL-G
- LU2B12BL-H
- LU2B12BL-I
- LU2B12BL-J
- LU2B12BL-K
- LU2B12BL-L
- LU2B12BL-M
- LU2B12BL-N
- LU2B12BL-O
- LU2B12BL-P
- LU2B12BL-Q
- LU2B12BL-R
- LU2B12BL-S
- LU2B12BL-T
- LU2B12BL-U
- LU2B12BL-V
- LU2B12BL-W
- LU2B12BL-X
- LU2B12BL-Y
- LU2B12BL-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier