- Description: TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 50 A - 110 V AC 50/60 Hz coil
- Product weight: 1.88 lb(US) (0.855 kg)
- Range of product: TeSys D
- IP degree of protection: IP20 front face conforming to IEC 60529
- Standards: CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508
- Device short name: LC1D
- Width: 2.17 in (55 mm)
- Height: 4.8 in (122 mm)
- Depth: 4.72 in (120 mm)
- Protective treatment: TH conforming to IEC 60068-2-30
- [Ui] rated insulation voltage: 600 V power circuit certifications CSA600 V power circuit certifications UL690 V power circuit conforming to IEC 60947-4-1690 V signaling circuit conforming to IEC 60947-1600 V signaling circuit certifications CSA600 V signaling circuit certifications UL
- [Uimp] rated impulse withstand voltage: Conforming to IEC 60947
- Operating altitude: 9842.52 ft. (3000 m) without derating in temperature
- Mechanical durability: 6 Mcycles
- Tightening torque: Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2Power circuit: 70.8 lbf.in (8 N.m) - on EverLink BTR screw connectors - cable 0.04...0.05 in² (25...35 mm²) hexagonal 0.16 in (4 mm)Power circuit : 5 N.m - on EverLink BTR screw connectors - cable 1...25 mm² hexagonal 4 mm
- Connections - terminals: Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable endControl circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable endPower circuit : screw connection 2 cable(s) 1...25 mm² - cable stiffness: flexible - with cable endPower circuit : screw connection 2 cable(s) 1...25 mm² - cable stiffness: solid - without cable endPower circuit : screw connection 2 cable(s) 1...25 mm² - cable stiffness: flexible - without cable endPower circuit : screw connection 1 cable(s) 1...35 mm² - cable stiffness: solid - without cable endPower circuit : screw connection 1 cable(s) 1...35 mm² - cable stiffness: flexible - without cable endPower circuit : screw connection 1 cable(s) 1...35 mm² - cable stiffness: flexible - with cable end
- Range: TeSys
- Mounting support: RailPlate
- [Ith] conventional free air thermal current: 80 A at <= 140 °F (60 °C) power circuit10 A at <= 140 °F (60 °C) signaling circuit
- System Voltage: <= 300 V DC power circuit<= 690 V AC 25...400 Hz power circuit
- Operating rate: 3600 cyc/h at <= 140 °F (60 °C)
- Product name: TeSys D
- [Uc] control circuit voltage: 110 V AC 50/60 Hz
- Electrical durability: 1.45 Mcycles 50 A AC-3 at Ue <= 440 V1.1 Mcycles 80 A AC-1 at Ue <= 440 V
- Insulation resistance: > 10 MOhm signaling circuit
- motor power kW: 22 kW at 380...400 V AC 50/60 Hz AC-325 kW at 415 V AC 50/60 Hz AC-330 kW at 440 V AC 50/60 Hz AC-330 kW at 500 V AC 50/60 Hz AC-333 kW at 660...690 V AC 50/60 Hz AC-315 kW at 220...230 V AC 50/60 Hz AC-311 kW at 400 V AC 50/60 Hz AC-4
- [Ie] rated operational current: 50 A (<= 140 °F (60 °C)) at <= 440 V AC AC-3 power circuit80 A (<= 140 °F (60 °C)) at <= 440 V AC AC-1 power circuit
- Utilization category: AC-3AC-1AC-4
- Control circuit voltage limits: 0.3...0.6 Uc drop-out at 140 °F (60 °C), AC 50/60 Hz0.8...1.1 Uc operational at 140 °F (60 °C), AC 50 Hz0.85...1.1 Uc operational at 140 °F (60 °C), AC 60 Hz
- Poles description: 3P
- Overvoltage category: III
- Operating time: 12...26 ms closing4...19 ms opening
- Associated fuse rating: 100 A gG at <= 690 V coordination type 1 power circuit100 A gG at <= 690 V coordination type 2 power circuit10 A gG signaling circuit conforming to IEC 60947-5-1
- Control circuit type: AC 50/60 Hz
- Coil technology: Without built-in suppressor module
- inrush power in VA: 140 VA at 68 °F (20 °C) (cos ? 0.75) 60 Hz160 VA at 68 °F (20 °C) (cos ? 0.75) 50 Hz
- Pollution degree: 3
- Product or component type: Contactor
- hold-in power consumption in VA: 13 VA at 68 °F (20 °C) (cos ? 0.3) 60 Hz15 VA at 68 °F (20 °C) (cos ? 0.3) 50 Hz
- Ambient air temperature for operation: 23...140 °F (-5...60 °C)
- Heat dissipation: 4...5 W at 50/60 Hz
- Ambient air temperature for storage: -76...176 °F (-60...80 °C)
- Contactor application: Resistive loadMotor control
- Auxiliary contacts type: Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1Type mirror contact (1 NC) conforming to IEC 60947-4-1
- Permissible ambient air temperature around the device: -40...158 °F (-40...70 °C) at Uc
- Signaling circuit frequency: 25...400 Hz
- Minimum switching current: 5 mA signaling circuit
- Fire resistance: 1562 °F (850 °C) conforming to IEC 60695-2-1
- Pole contact composition: 3 NO
- Minimum switching voltage: 17 V signaling circuit
- Flame retardance: V1 conforming to UL 94
- Non-overlap time: 1.5 ms on de-energisation (between NC and NO contact)1.5 ms on energisation (between NC and NO contact)
- Mechanical robustness: Vibrations contactor open 2 Gn, 5...300 HzVibrations contactor closed 4 Gn, 5...300 HzShocks contactor open 10 Gn for 11 msShocks contactor closed 15 Gn for 11 ms
- Power range: 7...11 kW 200...240 V 3 phases15...25 kW 200...240 V 3 phases15...25 kW 380...440 V 3 phases30...50 kW 380...440 V 3 phases30...50 kW 480...500 V 3 phases
- Motor power hp: 3 hp at 115 V AC 50/60 Hz 1 phase motors7.5 hp at 230/240 V AC 50/60 Hz 1 phase motors15 hp at 200/208 V AC 50/60 Hz 3 phases motors15 hp at 230/240 V AC 50/60 Hz 3 phases motors40 hp at 460/480 V AC 50/60 Hz 3 phases motors40 hp at 575/600 V AC 50/60 Hz 3 phases motors
- Motor starter type: Direct on-line contactor
- Contactor coil voltage: 110 V AC standard
- Auxiliary contact composition: 1 NO + 1 NC
- Irms rated making capacity: 900 A at 440 V power circuit conforming to IEC 60947140 A AC signaling circuit conforming to IEC 60947-5-1250 A DC signaling circuit conforming to IEC 60947-5-1
- Rated breaking capacity: 900 A at 440 V power circuit conforming to IEC 60947
- [Icw] rated short-time withstand current: 100 A 1 s signaling circuit120 A 500 ms signaling circuit140 A 100 ms signaling circuit400 A <= 104 °F (40 °C) 10 s power circuit810 A <= 104 °F (40 °C) 1 s power circuit84 A <= 104 °F (40 °C) 10 min power circuit208 A <= 104 °F (40 °C) 1 min power circuit
- Average impedance: 1.5 mOhm at 50 Hz - Ith 80 A power circuit
- Power dissipation per pole: 3.7 W AC-39.6 W AC-1
- Protective cover: With
- Product certifications: ULCSABVGOSTDNVGLRINACCCLROS (Lloyds register of shipping)
- Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1D50AF7 . Santa Clara Systems carries 10,416 items from Telemecanique.
- Tesys D Contactor - 3p(3 No) - Ac-3 - <= 440 V 50 A - 110 V Ac 50/60 Hz Coil
Alternates
Common Typos
- 1C1D50AF7
- 1C1D5OAF7
- 1C1DS0AF7
- 1C1DSOAF7
- 1CID50AF7
- 1CID5OAF7
- 1CIDS0AF7
- 1CIDSOAF7
- 1CLD50AF7
- 1CLD5OAF7
- 1CLDS0AF7
- 1CLDSOAF7
- IC1D50AF7
- IC1D5OAF7
- IC1DS0AF7
- LC1D5OAF7
- LC1DS0AF7
- LC1DSOAF7
- LCID50AF7
- LCID5OAF7
- LCIDS0AF7
- LCIDSOAF7
- LCLD50AF7
- LCLD5OAF7
- LCLDS0AF7
- LCLDSOAF7
Appended Numbers
- LC1D50AF7-A
- LC1D50AF7-B
- LC1D50AF7-C
- LC1D50AF7-D
- LC1D50AF7-E
- LC1D50AF7-F
- LC1D50AF7-G
- LC1D50AF7-H
- LC1D50AF7-I
- LC1D50AF7-J
- LC1D50AF7-K
- LC1D50AF7-L
- LC1D50AF7-M
- LC1D50AF7-N
- LC1D50AF7-O
- LC1D50AF7-P
- LC1D50AF7-Q
- LC1D50AF7-R
- LC1D50AF7-S
- LC1D50AF7-T
- LC1D50AF7-U
- LC1D50AF7-V
- LC1D50AF7-W
- LC1D50AF7-X
- LC1D50AF7-Y
- LC1D50AF7-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier