- Description: TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil
- Product weight: 1.18 lb(US) (0.535 kg)
- Range of product: TeSys D
- IP degree of protection: IP20 front face conforming to IEC 60529
- Standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
- Device short name: LC1D
- Width: 1.77 in (45 mm)
- Height: 3.35 in (85 mm)
- Depth: 3.98 in (101 mm)
- Protective treatment: TH conforming to IEC 60068-2-30
- [Ui] rated insulation voltage: 600 V power circuit certifications CSA, 600 V power circuit certifications UL, 690 V power circuit conforming to IEC 60947-4-1, 690 V signaling circuit conforming to IEC 60947-1, 600 V signaling circuit certifications CSA, 600 V signaling circuit certifications UL
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947
- Operating altitude: 9842.52 ft. (3000 m) without derating in temperature
- Mechanical durability: 30 Mcycles
- Tightening torque: Control circuit: 15.04 lbf.in (1.7 N.m) - on lugs-ring terminals - with screwdriver flat 6 mm screw : M3.5, Control circuit: 15.04 lbf.in (1.7 N.m) - on lugs-ring terminals - with screwdriver Philips No 2 screw : M3.5, Power circuit: 22.12 lbf.in (2.5 N.m) - on lugs-ring terminals - with screwdriver flat 8 mm screw : M4, Power circuit: 22.12 lbf.in (2.5 N.m) - on lugs-ring terminals - with screwdriver Philips No 2 screw : M4
- Connections - terminals: Control circuit: lugs-ring terminals - external diameter: 0.31 in (8 mm), Power circuit: lugs-ring terminals - external diameter: 0.39 in (10 mm)
- Range: TeSys
- Mounting support: Rail, Plate
- [Ith] conventional free air thermal current: 50 A at <= 140 F (60 C) power circuit, 10 A at <= 140 F (60 C) signaling circuit
- System Voltage: <= 300 V DC power circuit, <= 690 V AC 25...400 Hz power circuit
- Operating rate: 3600 cyc/h at <= 140 F (60 C)
- Product name: TeSys D
- [Uc] control circuit voltage: 24 V DC
- Electrical durability: 1.65 Mcycles 32 A AC-3 at Ue <= 440 V, 1.4 Mcycles 50 A AC-1 at Ue <= 440 V
- Insulation resistance: > 10 MOhm signaling circuit
- motor power kW: 15 kW at 380...400 V AC 50/60 Hz AC-3, 7.5 kW at 220...230 V AC 50/60 Hz AC-3, 18.5 kW at 500 V AC 50/60 Hz AC-3, 18.5 kW at 660...690 V AC 50/60 Hz AC-3, 15 kW at 415...440 V AC 50/60 Hz AC-3, 7.5 kW at 400 V AC 50/60 Hz AC-4
- [Ie] rated operational current: 32 A (<= 140 F (60 C)) at <= 440 V AC AC-3 power circuit, 50 A (<= 140 F (60 C)) at <= 440 V AC AC-1 power circuit
- Utilization category: AC-4, AC-1, AC-3
- Control circuit voltage limits: 0.1...0.3 Uc drop-out at 140 F (60 C), DC, 0.8...1.25 Uc operational at 140 F (60 C), DC
- Poles description: 3P
- Overvoltage category: III
- Operating time: 65.45...88.55 ms closing, 20...30 ms opening
- Associated fuse rating: 63 A gG at <= 690 V coordination type 1 power circuit, 63 A gG at <= 690 V coordination type 2 power circuit, 10 A gG signaling circuit conforming to IEC 60947-5-1
- Control circuit type: DC low consumption
- Coil technology: Built-in bidirectional peak limiting diode suppressor
- Time constant: 40 ms
- Pollution degree: 3
- Product or component type: Contactor
- inrush power in W: 2.4 W at 68 F (20 C)
- Ambient air temperature for operation: 23...140 F (-5...60 C)
- hold-in power consumption in W: 2.4 W at 68 F (20 C)
- Ambient air temperature for storage: -76...176 F (-60...80 C)
- Contactor application: Resistive load, Motor control
- Auxiliary contacts type: Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1, Type mirror contact (1 NC) conforming to IEC 60947-4-1
- Permissible ambient air temperature around the device: -40...158 F (-40...70 C) at Uc
- Signaling circuit frequency: 25...400 Hz
- Minimum switching current: 5 mA signaling circuit
- Fire resistance: 1562 F (850 C) conforming to IEC 60695-2-1
- Pole contact composition: 3 NO
- Minimum switching voltage: 17 V signaling circuit
- Flame retardance: V1 conforming to UL 94
- Non-overlap time: 1.5 ms on energisation between NC and NO contact, 1.5 ms on de-energisation between NC and NO contact
- Mechanical robustness: Vibrations contactor open 2 Gn, 5...300 Hz, Vibrations contactor closed 4 Gn, 5...300 Hz, Shocks contactor closed 15 Gn for 11 ms, Shocks contactor open 8 Gn for 11 ms
- Motor power hp: 2 hp at 115 V AC 50/60 Hz 1 phase motors, 5 hp at 230/240 V AC 50/60 Hz 1 phase motors, 7.5 hp at 200/208 V AC 50/60 Hz 3 phases motors, 10 hp at 230/240 V AC 50/60 Hz 3 phases motors, 20 hp at 460/480 V AC 50/60 Hz 3 phases motors, 30 hp at 575/600 V AC 50/60 Hz 3 phases motors
- Auxiliary contact composition: 1 NO + 1 NC
- Irms rated making capacity: 550 A at 440 V power circuit conforming to IEC 60947, 140 A AC signaling circuit conforming to IEC 60947-5-1, 250 A DC signaling circuit conforming to IEC 60947-5-1
- Rated breaking capacity: 550 A at 440 V power circuit conforming to IEC 60947
- [Icw] rated short-time withstand current: 138 A <= 104 F (40 C) 1 min power circuit, 260 A <= 104 F (40 C) 10 s power circuit, 430 A <= 104 F (40 C) 1 s power circuit, 60 A <= 104 F (40 C) 10 min power circuit, 100 A 1 s signaling circuit, 120 A 500 ms signaling circuit, 140 A 100 ms signaling circuit
- Average impedance: 2 mOhm at 50 Hz - Ith 50 A power circuit
- Power dissipation per pole: 2 W AC-3, 5 W AC-1
- Protective cover: With
- Product certifications: CCC, UL, GOST, BV, GL, DNV, CSA, LROS (Lloyds register of shipping), RINA
- Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1D326BL . Santa Clara Systems carries 10,416 items from Telemecanique.
- Tesys D Contactor - 3p(3 No) - Ac-3 - <= 440 V 32 A - 24 V Dc Coil
Alternates
Common Typos
- LC1D32681
- LC1D3268I
- LC1D3268L
- LC1D326B1
- LC1D326BI
- LC1D32G81
- LC1D32G8I
- LC1D32G8L
- LC1D32GB1
- LC1D32GBI
- LC1D32GBL
- LC1D3Z681
- LC1D3Z68I
- LC1D3Z68L
- LC1D3Z6B1
- LC1D3Z6BI
- LC1D3Z6BL
- LC1D3ZG81
- LC1D3ZG8I
- LC1D3ZG8L
- LC1D3ZGB1
- LC1D3ZGBI
- LC1D3ZGBL
- LCID326B1
- LCID326BI
- LCID326BL
Appended Numbers
- LC1D326BL-A
- LC1D326BL-B
- LC1D326BL-C
- LC1D326BL-D
- LC1D326BL-E
- LC1D326BL-F
- LC1D326BL-G
- LC1D326BL-H
- LC1D326BL-I
- LC1D326BL-J
- LC1D326BL-K
- LC1D326BL-L
- LC1D326BL-M
- LC1D326BL-N
- LC1D326BL-O
- LC1D326BL-P
- LC1D326BL-Q
- LC1D326BL-R
- LC1D326BL-S
- LC1D326BL-T
- LC1D326BL-U
- LC1D326BL-V
- LC1D326BL-W
- LC1D326BL-X
- LC1D326BL-Y
- LC1D326BL-Z
More Products Like This
-
LC1 D326B7
Telemecanique
-
LC1 D326G7
Telemecanique
-
LC1 D323JD
Telemecanique
-
LC1 D32JD
Telemecanique
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier