- Description: TeSys D contactor - 4P(2 NO + 2 NC) - AC-1 - <= 440 V 40 A - 110 V AC coil
- Product weight: 0.94 lb(US) (0.425 kg)
- Range of product: TeSys D
- IP degree of protection: IP20 front face conforming to IEC 60529
- Standards: CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508
- Device short name: LC1D
- Width: 1.77 in (45 mm)
- Height: 4.13 in (105 mm)
- Depth: 3.9 in (99 mm)
- Protective treatment: TH conforming to IEC 60068-2-30
- [Ui] rated insulation voltage: 600 V power circuit certifications CSA600 V power circuit certifications UL690 V power circuit conforming to IEC 60947-4-1690 V signaling circuit conforming to IEC 60947-1600 V signaling circuit certifications CSA600 V signaling circuit certifications UL
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947
- Operating altitude: 9842.52 ft. (3000 m) without derating in temperature
- Mechanical durability: 15 Mcycles
- Tightening torque: Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mmControl circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2Power circuit: 15.93 lbf.in (1.8 N.m) - on connector - with screwdriver flat Ø 6 mmPower circuit: 15.93 lbf.in (1.8 N.m) - on connector - with screwdriver Philips No 2
- Connections - terminals: Control circuit: screw clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable endControl circuit: screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable endControl circuit: screw clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable endPower circuit: connector 1 cable(s) 0...0.02 in² (2.5...10 mm²) - cable stiffness: flexible - without cable endPower circuit: connector 2 cable(s) 0...0.02 in² (2.5...10 mm²) - cable stiffness: flexible - without cable endPower circuit: connector 1 cable(s) 0...0.02 in² (2.5...10 mm²) - cable stiffness: flexible - with cable endPower circuit: connector 2 cable(s) 0...0.02 in² (2.5...10 mm²) - cable stiffness: flexible - with cable endPower circuit: connector 1 cable(s) 0...0.02 in² (2.5...16 mm²) - cable stiffness: solid - without cable endPower circuit: connector 2 cable(s) 0...0.02 in² (2.5...16 mm²) - cable stiffness: solid - without cable end
- Range: TeSys
- Mounting support: RailPlate
- [Ith] conventional free air thermal current: 40 A at <= 140 °F (60 °C) power circuit10 A at <= 140 °F (60 °C) signaling circuit
- System Voltage: <= 300 V DC power circuit<= 690 V AC 25...400 Hz power circuit
- Operating rate: 3600 cyc/h at <= 140 °F (60 °C)
- Product name: TeSys D
- [Uc] control circuit voltage: 110 V AC 50/60 Hz
- Electrical durability: 1.4 Mcycles 40 A AC-1 at Ue <= 440 V
- Insulation resistance: > 10 MOhm signaling circuit
- [Ie] rated operational current: 40 A (<= 140 °F (60 °C)) at <= 440 V AC AC-1 power circuit
- Utilization category: AC-1
- Control circuit voltage limits: 0.3...0.6 Uc drop-out at 140 °F (60 °C), AC 50/60 Hz0.8...1.1 Uc operational at 140 °F (60 °C), AC 50 Hz0.85...1.1 Uc operational at 140 °F (60 °C), AC 60 Hz
- Poles description: 4P
- Overvoltage category: III
- Operating time: 4...19 ms opening12...22 ms closing
- Associated fuse rating: 40 A gG at <= 690 V coordination type 2 power circuit63 A gG at <= 690 V coordination type 1 power circuit10 A gG signaling circuit conforming to IEC 60947-5-1
- Control circuit type: AC 50/60 Hz
- Coil technology: Without built-in suppressor module
- inrush power in VA: 70 VA at 68 °F (20 °C) (cos ? 0.75) 60 Hz70 VA at 68 °F (20 °C) (cos ? 0.75) 50 Hz
- Pollution degree: 3
- Product or component type: Contactor
- hold-in power consumption in VA: 7.5 VA at 68 °F (20 °C) (cos ? 0.3) 60 Hz7 VA at 68 °F (20 °C) (cos ? 0.3) 50 Hz
- Ambient air temperature for operation: 23...140 °F (-5...60 °C)
- Heat dissipation: 2...3 W at 50/60 Hz
- Ambient air temperature for storage: -76...176 °F (-60...80 °C)
- Contactor application: Resistive load
- Auxiliary contacts type: Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1Type mirror contact (1 NC) conforming to IEC 60947-4-1
- Permissible ambient air temperature around the device: -40...158 °F (-40...70 °C) at Uc
- Signaling circuit frequency: 25...400 Hz
- Minimum switching current: 5 mA signaling circuit
- Fire resistance: 1562 °F (850 °C) conforming to IEC 60695-2-1
- Pole contact composition: 2 NO + 2 NC
- Minimum switching voltage: 17 V signaling circuit
- Flame retardance: V1 conforming to UL 94
- Non-overlap time: 1.5 ms on energisation between NC and NO contact1.5 ms on de-energisation between NC and NO contact
- Mechanical robustness: Vibrations contactor open 2 Gn, 5...300 HzVibrations contactor closed 4 Gn, 5...300 HzShocks contactor closed 15 Gn for 11 msShocks contactor open 8 Gn for 11 ms
- Auxiliary contact composition: 1 NO + 1 NC
- Irms rated making capacity: 450 A at 440 V power circuit conforming to IEC 60947140 A AC signaling circuit conforming to IEC 60947-5-1250 A DC signaling circuit conforming to IEC 60947-5-1
- Rated breaking capacity: 450 A at 440 V power circuit conforming to IEC 60947
- [Icw] rated short-time withstand current: 120 A <= 104 °F (40 °C) 1 min power circuit240 A <= 104 °F (40 °C) 10 s power circuit380 A <= 104 °F (40 °C) 1 s power circuit50 A <= 104 °F (40 °C) 10 min power circuit100 A 1 s signaling circuit120 A 500 ms signaling circuit140 A 100 ms signaling circuit
- Average impedance: 2 mOhm at 50 Hz - Ith 40 A power circuit
- Power dissipation per pole: 3.2 W AC-1
- Protective cover: With
- Product certifications: CCCLROS (Lloyds register of shipping)BVDNVGOSTRINAULCSAGL
- Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1D258F7 . Santa Clara Systems carries 10,416 items from Telemecanique.
- Tesys D Contactor - 4p(2 No + 2 Nc) - Ac-1 - <= 440 V 40 A - 110 V Ac Coil
Alternates
Common Typos
- 1C1D258F7
- 1C1D25BF7
- 1C1D2S8F7
- LC1D25BF7
- LC1D2S8F7
- LC1D2SBF7
- LC1DZ58F7
- LC1DZ5BF7
- LC1DZS8F7
- LC1DZSBF7
- LCID258F7
- LCID25BF7
- LCID2S8F7
- LCID2SBF7
- LCIDZ58F7
- LCIDZ5BF7
- LCIDZS8F7
- LCIDZSBF7
- LCLD258F7
- LCLD25BF7
- LCLD2S8F7
- LCLD2SBF7
- LCLDZ58F7
- LCLDZ5BF7
- LCLDZS8F7
- LCLDZSBF7
Appended Numbers
- LC1D258F7-A
- LC1D258F7-B
- LC1D258F7-C
- LC1D258F7-D
- LC1D258F7-E
- LC1D258F7-F
- LC1D258F7-G
- LC1D258F7-H
- LC1D258F7-I
- LC1D258F7-J
- LC1D258F7-K
- LC1D258F7-L
- LC1D258F7-M
- LC1D258F7-N
- LC1D258F7-O
- LC1D258F7-P
- LC1D258F7-Q
- LC1D258F7-R
- LC1D258F7-S
- LC1D258F7-T
- LC1D258F7-U
- LC1D258F7-V
- LC1D258F7-W
- LC1D258F7-X
- LC1D258F7-Y
- LC1D258F7-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier