- Description: TeSys GV2 - Motor circuit breaker - thermal-magnetic - 13?18 A
- IP degree of protection: IP20 conforming to IEC 60529
- Standards: CSA C22.2UL 508NF C 63-650IEC 60947-2VDE 0113IEC 60947-1VDE 0660NF C 63-120EN 60204NF C 79-130IEC 60947-4-1
- Device short name: GV2P
- Width: 1.77 in (45 mm)
- Height: 3.5 in (89 mm)
- Depth: 3.82 in (97 mm)
- Protective treatment: TH
- [Ui] rated insulation voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-2
- Operating altitude: 6561.68 ft. (2000 m)
- Mechanical durability: 100000 cycles
- Tightening torque: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals
- Connections - terminals: Screw clamp terminals 2 cable(s) 0...0.01 in² (1...6 mm²) - cable stiffness : solidScrew clamp terminals 2 cable(s) 0...0.01 in² (1.5...6 mm²) - cable stiffness : flexible - without cable endScrew clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness : flexible - with cable end
- Range: TeSys
- Mounting support: RailPlate
- [Ith] conventional free air thermal current: 18 A conforming to IEC 60947-4-1
- System Voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2
- Operating rate: 25 cyc/h
- Product name: TeSys GV2
- Electrical durability: 100000 cycles AC-3 at 440 V
- motor power kW: 15 kW at 690 V AC 50/60 Hz9 kW at 500 V AC 50/60 Hz7.5 kW at 400/415 V AC 50/60 Hz
- Utilization category: AC-3 conforming to IEC 60947-4-1Category A conforming to IEC 60947-2
- Poles description: 3P
- Control type: Rotary knob
- Breaking capacity: 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-220 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-24 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-250 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
- Mounting position: VerticalHorizontal
- Network type: AC
- Product certifications: LROS (Lloyds register of shipping)CCCBVULCSARINAATEXUL 508 type EDNVEACEZUGLTSE
- Product or component type: Circuit breaker
- Network frequency: 50/60 Hz conforming to IEC 60947-4-1
- Device application: Motor
- Mounting mode: By Clips / By Screws
- IK degree of protection: IK04
- Trip unit technology: Thermal-magnetic
- Ambient air temperature for operation: -4...140 °F (-20...60 °C)
- Ambient air temperature for storage: -40...176 °F (-40...80 °C)
- Fire resistance: 1760 °F (960 °C) conforming to IEC 60695-2-1
- [Ics] rated service short-circuit breaking capacity: 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2100 % at 690 V AC 50/60 Hz conforming to IEC 60947-250 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-275 % at 440 V AC 50/60 Hz conforming to IEC 60947-275 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
- [In] rated current: 13...18 A
- Trip unit rating: 13...18 A
- Magnetic tripping current: 223 A
- Power dissipation per pole: 2.5 W
- Rated duty: Continuous conforming to IEC 60947-4-1
- Suitability for isolation: Yes conforming to IEC 60947-1
- Phase failure sensitivity: Yes conforming to IEC 60947-4-1
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on GV2P20 . Santa Clara Systems carries 10,431 items from Telemecanique.
- Tesys Gv2 - Motor Circuit Breaker - Thermal-Magnetic - 13?18 A
Alternates
- GV2P20H7
Common Typos
- 6V2P20
- 6V2P2O
- 6V2PZ0
- 6V2PZO
- 6VZP20
- 6VZP2O
- 6VZPZ0
- 6VZPZO
- GV2P2O
- GV2PZ0
- GV2PZO
- GVZP20
- GVZP2O
- GVZPZ0
- GVZPZO
Appended Numbers
- GV2P20-A
- GV2P20-B
- GV2P20-C
- GV2P20-D
- GV2P20-E
- GV2P20-F
- GV2P20-G
- GV2P20-H
- GV2P20-I
- GV2P20-J
- GV2P20-K
- GV2P20-L
- GV2P20-M
- GV2P20-N
- GV2P20-O
- GV2P20-P
- GV2P20-Q
- GV2P20-R
- GV2P20-S
- GV2P20-T
- GV2P20-U
- GV2P20-V
- GV2P20-W
- GV2P20-X
- GV2P20-Y
- GV2P20-Z
More Products Like This
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier