- Description: Key for interlock forced opening device - for preventa Safety detection
- Product weight: 0.21 lb(US) (0.095 kg)
- Range of product: OsiSense XC
- IP degree of protection: IP66 conforming to IEC 60529, IP67 conforming to IEC 60529
- Standards: EN/IEC 60947-5-1, CSA C22.2 No 14, UL 508, EN/IEC 60204-1
- Device short name: XCKP
- Width: 1.22 in (31 mm)
- Height: 2.56 in (65 mm)
- Depth: 1.18 in (30 mm)
- Protective treatment: TC
- [Ui] rated insulation voltage: 50 V conforming to CSA C22.2 No 14, 50 V, pollution degree 3 conforming to IEC 60947-1, 50 V conforming to UL 508
- [Uimp] rated impulse withstand voltage: 1.5 kV conforming to IEC 60664, 1.5 kV conforming to IEC 60947-1
- Mechanical durability: 15000000 cycles
- Shock resistance: 50 gn 11 ms conforming to IEC 60068-2-27
- Vibration resistance: 25 gn (f = 10...500 Hz) conforming to IEC 60068-2-6
- Electrical durability: 5000000 cycles DC-13, 24 V at 10 W, <= 60 cyc/mn operating rate at 0.5 load factor conforming to IEC 60947-5-1 appendix C, 5000000 cycles DC-13, 48 V at 7 W, <= 60 cyc/mn operating rate at 0.5 load factor conforming to IEC 60947-5-1 appendix C
- Electrical connection: DEUTSCH connector male 4 pins
- [Ie] rated operational current: 3 A at 50 V - utilisation category AC-15 conforming to EN/IEC 60947-5-1 appendix A, 0.27 A at 50 V - utilisation category DC-13 conforming to EN/IEC 60947-5-1 appendix A
- Material: Plastic
- Number of poles: 2
- Head type: Plunger head
- Series name: Standard format
- Body material: Plastic
- Product or component type: Limit switch
- Head material: Zamak
- Fixing mode: By the body
- IK degree of protection: IK04 conforming to EN 50102
- Sensor design: Compact form C conforming to CENELEC EN 50047
- Movement of operating head: Linear
- Electrical shock protection class: Class II conforming to IEC 61140, Class II conforming to NF C 20-030
- Body type: Fixed
- Type of operator: Metal spring return roller plunger
- Ambient air temperature for operation: -13...158 F (-25...70 C)
- Switch actuation: By 30 cam
- Ambient air temperature for storage: -40...158 F (-40...70 C)
- Type of approach: 2 directions lateral approach
- Product certifications: CCC, cURus
- Contacts type and composition: 1 NC + 1 NO
- Contacts insulation form: Zb
- Contact operation: Snap action
- Positive opening: With
- Positive opening minimum force: 36 N
- Minimum force for tripping: 12 N
- Maximum actuation speed: 1.64 ft/s (0.5 m/s)
- Repeat accuracy: 0.1 mm on the tripping points with 1 million operating cycles
- [Ithe] conventional enclosed thermal current: 5:00 AM
- Resistance across terminals: <= 25 MOhm conforming to IEC 60255-7 category 3
- Short-circuit protection: 6 A gG cartridge fuse
- terminals description ISO n1: (13-14)NO, (21-22)NC
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on XCKY04 . Santa Clara Systems carries 10,327 items from Telemecanique.
- Key For Interlock Forced Opening Device - For Preventa Safety Detection
Alternates
Common Typos
- XCKYO4
Appended Numbers
- XCKY04-A
- XCKY04-B
- XCKY04-C
- XCKY04-D
- XCKY04-E
- XCKY04-F
- XCKY04-G
- XCKY04-H
- XCKY04-I
- XCKY04-J
- XCKY04-K
- XCKY04-L
- XCKY04-M
- XCKY04-N
- XCKY04-O
- XCKY04-P
- XCKY04-Q
- XCKY04-R
- XCKY04-S
- XCKY04-T
- XCKY04-U
- XCKY04-V
- XCKY04-W
- XCKY04-X
- XCKY04-Y
- XCKY04-Z
More Products Like This
-
XCK J1424485
Telemecanique
-
XCK Y01
Telemecanique
-
XCK Y02
Telemecanique
-
XCK Y03
Telemecanique
Customers Are Also Buying
-
440K-C21061
Allen Bradley
-
440R-D22R2
Allen Bradley
-
140M-C2E-C10
Allen Bradley
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier