- Description: standard control unit LUCA - class 10 - 0.35...1.4 A - 110...220 V DC/AC
- Product weight: 0.3 lb(US) (0.135 kg)
- IP degree of protection: IP20 front panel and wired terminals conforming to IEC 60947-1, IP20 other faces conforming to IEC 60947-1, IP40 front panel outside connection zone conforming to IEC 60947-1
- Standards: CSA C22.2 No 14 type E, EN 60947-6-2, IEC 60947-6-2, UL 508 type E with phase barrier
- Device short name: LUCA
- Protective treatment: TH conforming to IEC 60068
- [Ui] rated insulation voltage: 600 V conforming to CSA C22.2 No 14, 600 V conforming to UL 508, 690 V conforming to IEC 60947-1
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-6-2
- Operating altitude: 6561.68 ft. (2000 m)
- Range: TeSys
- Product name: TeSys U
- [Uc] control circuit voltage: 110...220 V DC, 110...240 V AC
- Shock resistance: 10 gn power poles open conforming to IEC 60068-2-27, 15 gn power poles closed conforming to IEC 60068-2-27
- Vibration resistance: 2 gn 5...300 Hz power poles open conforming to IEC 60068-2-6, 4 gn 5...300 Hz power poles closed conforming to IEC 60068-2-6
- motor power kW: 0.25 kW at 400...440 V AC 50/60 Hz
- Utilization category: AC-44, AC-41, AC-43
- Control circuit voltage limits: 88...242 V DC circuit 110...220 V in operation, 88...264 V AC circuit 110...240 V in operation
- Operating time: 35 ms opening with LUB12 control circuit, 35 ms opening with LUB32 control circuit, 50 ms closing with LUB12 control circuit, 50 ms closing with LUB32 control circuit
- Function available: Manual reset, Earth fault protection, Protection against phase failure and phase imbalance, Protection against overload and short-circuit
- Heat dissipation: 2 W control circuit with LUB12, 3 W control circuit with LUB32
- Mounting mode: Plug-in
- Immunity to micro breaks: 3 ms
- Mounting location: Front side
- Immunity to voltage dips: 70 % 500 ms conforming to IEC 61000-4-11
- Product or component type: Standard control unit
- Product specific application: Basic protection requirements for motor starters: overload and short-circuit
- Typical current consumption: 25 mA at 110...240 V AC I rms sealed with LUB12, 25 mA at 110...240 V AC I rms sealed with LUB32, 280 mA at 110...220 V DC I maximum while closing with LUB12, 280 mA at 110...220 V DC I maximum while closing with LUB32, 280 mA at 110...240 V AC I maximum while closing with LUB12, 280 mA at 110...240 V AC I maximum while closing with LUB32, 35 mA at 110...220 V DC I rms sealed with LUB12, 35 mA at 110...220 V DC I rms sealed with LUB32
- Product certifications: BV, GL, ASEFA, CSA, DNV, ATEX, LROS (Lloyds register of shipping), UL, GOST, CCC, ABS
- Product compatibility: LUFC00, LUFN
- Load type: 3-phase motor - cooling: self-cooled
- Tripping threshold: 14.2 x Ir +/- 20 %
- Ambient air temperature for operation: -13...158 F (-25...70 C)
- Thermal protection adjustment range: 0.35...1.4 A
- Ambient air temperature for storage: -40...185 F (-40...85 C)
- Thermal overload class: Class 10 - frequency limit: 40...60 Hz - temperature compensation: -13...158 F (-25...70 C) - conforming to IEC 60947-6-2, Class 10 - frequency limit: 40...60 Hz - temperature compensation: -13...158 F (-25...70 C) - conforming to UL 508, Class 20 - frequency limit: 40...60 Hz - temperature compensation: -13...158 F (-25...70 C) - conforming to IEC 60947-6-2, Class 20 - frequency limit: 40...60 Hz - temperature compensation: -13...158 F (-25...70 C) - conforming to UL 508
- Safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
- Fire resistance: 1202 F (650 C) conforming to IEC 60695-2-12, 1760 F (960 C) parts supporting live components conforming to IEC 60695-2-12
- Resistance to electrostatic discharge: 8 kV level 3 in open air conforming to IEC 61000-4-2, 8 kV level 4 on contact conforming to IEC 61000-4-2
- Non-dissipating shock wave: 1 kV serial mode conforming to IEC 60947-6-2, 2 kV common mode conforming to IEC 60947-6-2
- Resistance to radiated fields: 9.14 V/yd (10 V/m) 3 conforming to IEC 61000-4-3
- Resistance to fast transients: 2 kV class 3 serial link conforming to IEC 61000-4-4, 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
- Immunity to radio electric fields: 10 V conforming to IEC 61000-4-6
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LUCA1XFU . Santa Clara Systems carries 10,326 items from Telemecanique.
- Standard Control Unit Luca - Class 10 - 0.35...1.4 A - 110...220 V Dc/ac
Alternates
Common Typos
- 1UCA1XFU
- 1UCAIXFU
- 1UCALXFU
- IUCA1XFU
- IUCAIXFU
- IUCALXFU
- LUCAIXFU
- LUCALXFU
Appended Numbers
- LUCA1XFU-A
- LUCA1XFU-B
- LUCA1XFU-C
- LUCA1XFU-D
- LUCA1XFU-E
- LUCA1XFU-F
- LUCA1XFU-G
- LUCA1XFU-H
- LUCA1XFU-I
- LUCA1XFU-J
- LUCA1XFU-K
- LUCA1XFU-L
- LUCA1XFU-M
- LUCA1XFU-N
- LUCA1XFU-O
- LUCA1XFU-P
- LUCA1XFU-Q
- LUCA1XFU-R
- LUCA1XFU-S
- LUCA1XFU-T
- LUCA1XFU-U
- LUCA1XFU-V
- LUCA1XFU-W
- LUCA1XFU-X
- LUCA1XFU-Y
- LUCA1XFU-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier