- Description: TeSys K contactor - 4P (2 NO + 2 NC) - AC-1 <= 440 V 20 A - 110 V AC coil
- Product weight: 0.4 lb(US) (0.18 kg)
- Range of product: TeSys K
- IP degree of protection: IP2x conforming to VDE 0106
- Standards: BS 5424, IEC 60947, NF C 63-110, VDE 0660
- Device short name: LC1K
- Width: 1.77 in (45 mm)
- Height: 2.28 in (58 mm)
- Depth: 2.24 in (57 mm)
- Protective treatment: TC conforming to IEC 60068, TC conforming to DIN 50016
- [Ui] rated insulation voltage: 600 V power circuit conforming to CSA C22.2 No 14, 690 V power circuit conforming to IEC 60947-4-1, 600 V power circuit conforming to UL 508
- [Uimp] rated impulse withstand voltage: 8 kV
- Operating altitude: 6561.68 ft. (2000 m) without derating in temperature
- Mechanical durability: 10 Mcycles
- Tightening torque: 11.5 lbf.in (1.3 N.m) - on screw clamp terminals - with screwdriver Philips No 2, 11.5 lbf.in (1.3 N.m) - on screw clamp terminals - with screwdriver flat 6 mm
- Connections - terminals: Screw clamp terminals 1 cable(s) 0...0.01 in (1.5...4 mm) - cable stiffness: solid, Screw clamp terminals 1 cable(s) 0...0.01 in (0.75...4 mm) - cable stiffness: flexible - without cable end, Screw clamp terminals 1 cable(s) 0...0 in (0.34...2.5 mm) - cable stiffness: flexible - with cable end, Screw clamp terminals 2 cable(s) 0...0.01 in (1.5...4 mm) - cable stiffness: solid, Screw clamp terminals 2 cable(s) 0...0.01 in (0.75...4 mm) - cable stiffness: flexible - without cable end, Screw clamp terminals 2 cable(s) 0...0 in (0.34...1.5 mm) - cable stiffness: flexible - with cable end
- Range: TeSys
- Mounting support: Plate, Rail
- [Ith] conventional free air thermal current: 20 A at <= 122 F (50 C) power circuit
- System Voltage: 690 V AC 50/60 Hz power circuit
- Operating rate: 3600 cyc/h
- Product name: TeSys K
- [Uc] control circuit voltage: 110 V AC 50/60 Hz
- Electrical durability: 0.18 Mcycles 20 A AC-1 at Ue <= 440 V
- [Ie] rated operational current: 20 A (<= 122 F (50 C)) at <= 440 V AC AC-1 power circuit, 16 A (<= 158 F (70 C)) at 690 V AC AC-1 power circuit
- Utilization category: AC-1
- Control circuit voltage limits: 0.2...0.75 Uc at <= 122 F (50 C) drop-out, 0.8...1.15 Uc at <= 122 F (50 C) operational
- Poles description: 4P
- Overvoltage category: III
- Operating time: 10...20 ms coil de-energisation and NO opening, 5...15 ms coil energisation and NC opening, 10...20 ms coil energisation and NO closing, 15...25 ms coil de-energisation and NC closing
- Associated fuse rating: 25 A gG at <= 440 V power circuit, 25 A aM power circuit
- Control circuit type: AC 50/60 Hz
- Product certifications: UL, CSA
- Product or component type: Contactor
- Pole contact composition: 2 NO + 2 NC
- Ambient air temperature for operation: -13...122 F (-25...50 C)
- Device application: Control
- Ambient air temperature for storage: -58...176 F (-50...80 C)
- Contactor application: Resistive load
- Flame retardance: V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102
- Irms rated making capacity: 110 A AC power circuit conforming to NF C 63-110, 110 A AC power circuit conforming to IEC 60947
- Rated breaking capacity: 110 A at 415 V conforming to IEC 60947, 110 A at 440 V conforming to IEC 60947, 80 A at 500 V conforming to IEC 60947, 110 A at 220...230 V conforming to IEC 60947, 110 A at 380...400 V conforming to IEC 60947, 70 A at 660...690 V conforming to IEC 60947
- [Icw] rated short-time withstand current: 20 A <= 50 C >= 15 min power circuit, 90 A <= 122 F (50 C) 1 s power circuit, 85 A <= 122 F (50 C) 5 s power circuit, 80 A <= 122 F (50 C) 10 s power circuit, 60 A <= 122 F (50 C) 30 s power circuit, 45 A <= 122 F (50 C) 1 min power circuit, 40 A <= 122 F (50 C) 3 min power circuit
- Average impedance: 3 mOhm at 50 Hz - Ith 20 A power circuit
- inrush power in VA: 30 VA at 68 F (20 C)
- hold-in power consumption in VA: 4.5 VA at 68 F (20 C)
- Heat dissipation: 1.3 W
- Signaling circuit frequency: <= 400 Hz
- Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
- Mechanical robustness: Shocks contactor closed, on X axis 10 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis 15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Z axis 15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on X axis 6 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis 10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis 10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed 4 Gn, 5...300 Hz IEC 60068-2-6, Vibrations contactor opened 2 Gn, 5...300 Hz IEC 60068-2-6
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1K09008F7 . Santa Clara Systems carries 10,327 items from Telemecanique.
- Tesys K Contactor - 4p (2 No + 2 Nc) - Ac-1 <= 440 V 20 A - 110 V Ac Coil
Alternates
Common Typos
- LC1K0900BF7
- LC1K090O8F7
- LC1K090OBF7
- LC1K09O08F7
- LC1K09O0BF7
- LC1K09OO8F7
- LC1K09OOBF7
- LC1KO9008F7
- LC1KO900BF7
- LC1KO90O8F7
- LC1KO90OBF7
- LC1KO9O08F7
- LC1KO9O0BF7
- LC1KO9OO8F7
- LC1KO9OOBF7
- LCIK09008F7
- LCIK0900BF7
- LCIK090O8F7
- LCIK090OBF7
- LCIK09O08F7
- LCIK09O0BF7
- LCIK09OO8F7
- LCIK09OOBF7
- LCIKO9008F7
- LCIKO900BF7
- LCIKO90O8F7
Appended Numbers
- LC1K09008F7-A
- LC1K09008F7-B
- LC1K09008F7-C
- LC1K09008F7-D
- LC1K09008F7-E
- LC1K09008F7-F
- LC1K09008F7-G
- LC1K09008F7-H
- LC1K09008F7-I
- LC1K09008F7-J
- LC1K09008F7-K
- LC1K09008F7-L
- LC1K09008F7-M
- LC1K09008F7-N
- LC1K09008F7-O
- LC1K09008F7-P
- LC1K09008F7-Q
- LC1K09008F7-R
- LC1K09008F7-S
- LC1K09008F7-T
- LC1K09008F7-U
- LC1K09008F7-V
- LC1K09008F7-W
- LC1K09008F7-X
- LC1K09008F7-Y
- LC1K09008F7-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier