- Description: TeSys F contactor - 3P(3 NO) - AC-3 - <= 440 V 265 A - without coil
- Product weight: 18.83 lb(US) (8.54 kg)
- IP degree of protection: IP20 front face with shrouds (ordered separately) conforming to IEC 60529, IP20 front face with shrouds (ordered separately) conforming to VDE 0106
- Standards: EN 60947-1, IEC 60947-1, EN 60947-4-1, JIS C8201-4-1, IEC 60947-4-1
- Device short name: LC1F
- Width: 7.93 in (201.5 mm)
- Height: 7.99 in (203 mm)
- Depth: 8.39 in (213 mm)
- Protective treatment: TH
- [Ui] rated insulation voltage: 1000 V conforming to IEC 60947-4-1, 1500 V conforming to VDE 0110 group C
- [Uimp] rated impulse withstand voltage: 8 kV
- Operating altitude: 9842.52 ft. (3000 m) without derating in temperature
- Tightening torque: Power circuit: 309.73 lbf.in (35 N.m)
- Connections - terminals: Power circuit: connector 1 cable(s) 0.37 in (240 mm), Power circuit: lugs-ring terminals 1 cable(s) 0.37 in (240 mm), Power circuit: bar 2 x ( 32 x 4 mm), Power circuit : bolted connection
- Range: TeSys
- Mounting support: Plate
- [Ith] conventional free air thermal current: 350 A at <= 104 F (40 C)
- System Voltage: <= 1000 V AC 50/60 Hz, <= 460 V DC
- Product name: TeSys F
- motor power kW: 132 kW at 380...400 V AC 50/60 Hz AC-3, 140 kW at 415 V AC 50/60 Hz AC-3, 140 kW at 440 V AC 50/60 Hz AC-3, 160 kW at 500 V AC 50/60 Hz AC-3, 160 kW at 660?690 V AC 50/60 Hz AC-3, 147 kW at 1000 V AC 50/60 Hz AC-3, 51 kW at 400 V AC 50/60 Hz AC-4, 75 kW at 220...240 V AC 50/60 Hz AC-3
- [Ie] rated operational current: 350 A (<= 104 F (40 C)) at <= 440 V AC AC-1, 265 A (<= 131 F (55 C)) at <= 440 V AC AC-3
- Utilization category: AC-1, AC-4, AC-3
- Poles description: 3P
- Overvoltage category: III
- Associated fuse rating: 315 A aM at <= 440 V, 400 A gG at <= 440 V
- Product or component type: Contactor
- Ambient air temperature for operation: 23...131 F (-5...55 C)
- Irms rated making capacity: 2650 A AC conforming to IEC 60947-4-1
- Ambient air temperature for storage: -76...176 F (-60...80 C)
- Contactor application: Motor control, Resistive load
- Rated breaking capacity: 2120 A conforming to IEC 60947-4-1
- Permissible ambient air temperature around the device: -40...158 F (-40...70 C)
- [Icw] rated short-time withstand current: 2200 A <= 104 F (40 C) 10 s, 1230 A <= 104 F (40 C) 30 s, 950 A <= 104 F (40 C) 1 min, 620 A <= 104 F (40 C) 3 min, 480 A <= 104 F (40 C) 10 min
- Mechanical robustness: Vibrations contactor closed 5 Gn, 5...300 Hz, Vibrations contactor open 2 Gn, 5...300 Hz, Shocks contactor closed 15 Gn for 11 ms, Shocks contactor open 6 Gn for 11 ms
- Pole contact composition: 3 NO
- Average impedance: 0.3 mOhm at 50 Hz - Ith 350 A
- Power dissipation per pole: 21 W AC-3, 37 W AC-1
- Product certifications: RMRoS, DNV, CSA, RINA, ABS, CB, BV, LROS (Lloyds register of shipping), UL
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1F265 . Santa Clara Systems carries 10,416 items from Telemecanique.
- Tesys F Contactor - 3p(3 No) - Ac-3 - <= 440 V 265 A - Without Coil
Alternates
Common Typos
- 1C1F265
- 1C1F26S
- 1C1F2G5
- LC1F26S
- LC1F2G5
- LC1F2GS
- LC1FZ65
- LC1FZ6S
- LC1FZG5
- LC1FZGS
- LCIF265
- LCIF26S
- LCIF2G5
- LCIF2GS
- LCIFZ65
- LCIFZ6S
- LCIFZG5
- LCIFZGS
- LCLF265
- LCLF26S
- LCLF2G5
- LCLF2GS
- LCLFZ65
- LCLFZ6S
- LCLFZG5
- LCLFZGS
Appended Numbers
- LC1F265-A
- LC1F265-B
- LC1F265-C
- LC1F265-D
- LC1F265-E
- LC1F265-F
- LC1F265-G
- LC1F265-H
- LC1F265-I
- LC1F265-J
- LC1F265-K
- LC1F265-L
- LC1F265-M
- LC1F265-N
- LC1F265-O
- LC1F265-P
- LC1F265-Q
- LC1F265-R
- LC1F265-S
- LC1F265-T
- LC1F265-U
- LC1F265-V
- LC1F265-W
- LC1F265-X
- LC1F265-Y
- LC1F265-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier