• Telemecanique LC1 D150M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 220 V AC 50/60 Hz coil Product Image
  • Telemecanique LC1 D150M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 220 V AC 50/60 Hz coil Product Image
  • Telemecanique LC1 D150M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 220 V AC 50/60 Hz coil Product Image
  • Telemecanique LC1 D150M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 220 V AC 50/60 Hz coil Product Image
  • Telemecanique LC1 D150M7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 220 V AC 50/60 Hz coil Product Image
  • Telemecanique LC1 D150M7 Barcode

LC1D150M7

Get a Quote

Current response time:

9 Minutes 29 Seconds
  • Description: TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 150 A - 220 V AC 50/60 Hz coil
  • Product weight: 5.51 lb(US) (2.5 kg)
  • Range of product: TeSys D
  • IP degree of protection: IP20 front face conforming to IEC 60529
  • Standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
  • Device short name: LC1D
  • Width: 4.72 in (120 mm)
  • Height: 6.22 in (158 mm)
  • Depth: 5.35 in (136 mm)
  • Protective treatment: TH conforming to IEC 60068-2-30
  • [Ui] rated insulation voltage: 1000 V power circuit conforming to IEC 60947-4-1, 600 V power circuit certifications CSA, 600 V power circuit certifications UL, 690 V signaling circuit conforming to IEC 60947-1, 600 V signaling circuit certifications CSA, 600 V signaling circuit certifications UL
  • [Uimp] rated impulse withstand voltage: Conforming to IEC 60947
  • Operating altitude: 9842.52 ft. (3000 m) without derating in temperature
  • Mechanical durability: 8 Mcycles
  • Tightening torque: Control circuit: 10.62 lbf.in (1.2 N.m) - on screw clamp terminals - with screwdriver flat 6 mm, Control circuit: 10.62 lbf.in (1.2 N.m) - on screw clamp terminals - with screwdriver Philips No 2, Power circuit: 106.19 lbf.in (12 N.m) - on connector hexagonal 0.16 in (4 mm)
  • Connections - terminals: Control circuit: screw clamp terminals 2 cable(s) 0...0 in (1...2.5 mm) - cable stiffness: flexible - without cable end, Control circuit: screw clamp terminals 2 cable(s) 0...0 in (1...2.5 mm) - cable stiffness: flexible - with cable end, Control circuit: screw clamp terminals 2 cable(s) 0...0 in (1...2.5 mm) - cable stiffness: solid - without cable end, Control circuit: screw clamp terminals 1 cable(s) 0...0 in (1...2.5 mm) - cable stiffness: flexible - with cable end, Control circuit: screw clamp terminals 1 cable(s) 0...0 in (1...2.5 mm) - cable stiffness: flexible - without cable end, Control circuit: screw clamp terminals 1 cable(s) 0...0 in (1...2.5 mm) - cable stiffness: solid - without cable end, Power circuit: connector 1 cable(s) 0.02...0.19 in (10...120 mm) - cable stiffness: flexible - without cable end, Power circuit: connector 2 cable(s) 0.02...0.08 in (10...50 mm) - cable stiffness: flexible - without cable end, Power circuit: connector 1 cable(s) 0.02...0.19 in (10...120 mm) - cable stiffness: flexible - with cable end, Power circuit: connector 2 cable(s) 0.02...0.08 in (10...50 mm) - cable stiffness: flexible - with cable end, Power circuit: connector 1 cable(s) 0.02...0.19 in (10...120 mm) - cable stiffness: solid - without cable end, Power circuit: connector 2 cable(s) 0.02...0.08 in (10...50 mm) - cable stiffness: solid - without cable end
  • Range: TeSys
  • Mounting support: Plate, Rail
  • [Ith] conventional free air thermal current: 200 A at <= 140 F (60 C) power circuit
  • System Voltage: <= 300 V DC power circuit, <= 1000 V AC 25...400 Hz power circuit
  • Operating rate: 1200 cyc/h at <= 140 F (60 C)
  • Product name: TeSys D
  • [Uc] control circuit voltage: 220 V AC 50/60 Hz
  • Electrical durability: 0.85 Mcycles 150 A AC-3 at Ue <= 440 V, 1 Mcycles 200 A AC-1 at Ue <= 440 V
  • Insulation resistance: > 10 MOhm signaling circuit
  • motor power kW: 40 kW at 220...230 V AC 50/60 Hz AC-3, 75 kW at 380...400 V AC 50/60 Hz AC-3, 80 kW at 415...440 V AC 50/60 Hz AC-3, 90 kW at 500 V AC 50/60 Hz AC-3, 100 kW at 660...690 V AC 50/60 Hz AC-3, 75 kW at 1000 V AC 50/60 Hz AC-3, 22 kW at 400 V AC 50/60 Hz AC-4
  • [Ie] rated operational current: 200 A (<= 140 F (60 C)) at <= 440 V AC AC-1 power circuit, 150 A (<= 140 F (60 C)) at <= 440 V AC AC-3 power circuit
  • Utilization category: AC-4, AC-1, AC-3
  • Control circuit voltage limits: 0.3...0.5 Uc drop-out at 131 F (55 C), AC 50/60 Hz, 0.8...1.15 Uc operational at 131 F (55 C), AC 50/60 Hz
  • Poles description: 3P
  • Overvoltage category: III
  • Operating time: 20...35 ms closing, 40...75 ms opening
  • Associated fuse rating: 250 A gG at <= 690 V coordination type 2 power circuit, 315 A gG at <= 690 V coordination type 1 power circuit, 10 A gG signaling circuit conforming to IEC 60947-5-1
  • Control circuit type: AC 50/60 Hz
  • Coil technology: Built-in bidirectional peak limiting diode suppressor
  • inrush power in VA: 280...350 VA at 68 F (20 C) (cos ? 0.9) 60 Hz, 280...350 VA at 68 F (20 C) (cos ? 0.9) 50 Hz
  • Pollution degree: 3
  • Product or component type: Contactor
  • hold-in power consumption in VA: 2...18 VA at 68 F (20 C) (cos ? 0.9) 60 Hz, 2...18 VA at 68 F (20 C) (cos ? 0.9) 50 Hz
  • Ambient air temperature for operation: 23...140 F (-5...60 C)
  • Heat dissipation: 3...4.5 W at 50/60 Hz
  • Ambient air temperature for storage: -76...176 F (-60...80 C)
  • Contactor application: Resistive load, Motor control
  • Auxiliary contacts type: Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1, Type mirror contact (1 NC) conforming to IEC 60947-4-1
  • Permissible ambient air temperature around the device: -40...158 F (-40...70 C) at Uc
  • Signaling circuit frequency: 25...400 Hz
  • Minimum switching current: 5 mA signaling circuit
  • Fire resistance: 1562 F (850 C) conforming to IEC 60695-2-1
  • Pole contact composition: 3 NO
  • Minimum switching voltage: 17 V signaling circuit
  • Flame retardance: V1 conforming to UL 94
  • Non-overlap time: 1.5 ms on de-energisation (between NC and NO contact), 1.5 ms on energisation (between NC and NO contact)
  • Mechanical robustness: Vibrations contactor open 2 Gn, 5...300 Hz, Vibrations contactor closed 4 Gn, 5...300 Hz, Shocks contactor closed 15 Gn for 11 ms, Shocks contactor open 6 Gn for 11 ms
  • Power range: 30...50 kW 200...240 V 3 phases, 55...100 kW 380...440 V 3 phases, 55...100 kW 480...500 V 3 phases
  • Motor power hp: 40 hp at 200/208 V AC 50/60 Hz 3 phases motors, 50 hp at 230/240 V AC 50/60 Hz 3 phases motors, 100 hp at 460/480 V AC 50/60 Hz 3 phases motors, 125 hp at 575/600 V AC 50/60 Hz 3 phases motors
  • Motor starter type: Direct on-line contactor
  • Contactor coil voltage: 220 V AC standard
  • Auxiliary contact composition: 1 NO + 1 NC
  • Irms rated making capacity: 1660 A at 440 V power circuit conforming to IEC 60947, 140 A AC signaling circuit conforming to IEC 60947-5-1, 250 A DC signaling circuit conforming to IEC 60947-5-1
  • Rated breaking capacity: 1400 A at 440 V power circuit conforming to IEC 60947
  • [Icw] rated short-time withstand current: 100 A 1 s signaling circuit, 120 A 500 ms signaling circuit, 140 A 100 ms signaling circuit, 250 A <= 104 F (40 C) 10 min power circuit, 580 A <= 104 F (40 C) 1 min power circuit, 1200 A <= 104 F (40 C) 10 s power circuit, 1400 A <= 104 F (40 C) 1 s power circuit
  • Average impedance: 0.6 mOhm at 50 Hz - Ith 200 A power circuit
  • Power dissipation per pole: 24 W AC-1, 13.5 W AC-3
  • Protective cover: With
  • Product certifications: BV, RINA, DNV, CSA, LROS (Lloyds register of shipping), GOST, CCC, UL, GL
  • Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1D150M7 . Santa Clara Systems carries 10,327 items from Telemecanique.
  • Tesys D Contactor - 3p(3 No) - Ac-3 - <= 440 V 150 A - 220 V Ac 50/60 Hz Coil

Alternates

    Common Typos

    • LC1D15OM7
    • LC1D1S0M7
    • LC1D1SOM7
    • LC1DI50M7
    • LC1DI5OM7
    • LC1DIS0M7
    • LC1DISOM7
    • LC1DL50M7
    • LC1DL5OM7
    • LC1DLS0M7
    • LC1DLSOM7
    • LCID150M7
    • LCID15OM7
    • LCID1S0M7
    • LCID1SOM7
    • LCIDI50M7
    • LCIDI5OM7
    • LCIDIS0M7
    • LCIDISOM7
    • LCIDL50M7
    • LCIDL5OM7
    • LCIDLS0M7
    • LCIDLSOM7
    • LCLD150M7
    • LCLD15OM7
    • LCLD1S0M7

    Appended Numbers

    • LC1D150M7-A
    • LC1D150M7-B
    • LC1D150M7-C
    • LC1D150M7-D
    • LC1D150M7-E
    • LC1D150M7-F
    • LC1D150M7-G
    • LC1D150M7-H
    • LC1D150M7-I
    • LC1D150M7-J
    • LC1D150M7-K
    • LC1D150M7-L
    • LC1D150M7-M
    • LC1D150M7-N
    • LC1D150M7-O
    • LC1D150M7-P
    • LC1D150M7-Q
    • LC1D150M7-R
    • LC1D150M7-S
    • LC1D150M7-T
    • LC1D150M7-U
    • LC1D150M7-V
    • LC1D150M7-W
    • LC1D150M7-X
    • LC1D150M7-Y
    • LC1D150M7-Z

    More Products Like This

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo