- Description: TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 115 A - 220 V AC 50/60 Hz coil
- Product weight: 5.51 lb(US) (2.5 kg)
- Range of product: TeSys D
- IP degree of protection: IP20 front face conforming to IEC 60529
- Standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
- Device short name: LC1D
- Width: 4.72 in (120 mm)
- Height: 6.22 in (158 mm)
- Depth: 5.35 in (136 mm)
- Protective treatment: TH conforming to IEC 60068-2-30
- [Ui] rated insulation voltage: 1000 V power circuit conforming to IEC 60947-4-1, 600 V power circuit certifications CSA, 600 V power circuit certifications UL, 690 V signaling circuit conforming to IEC 60947-1, 600 V signaling circuit certifications CSA, 600 V signaling circuit certifications UL
- [Uimp] rated impulse withstand voltage: Conforming to IEC 60947
- Operating altitude: 9842.52 ft. (3000 m) without derating in temperature
- Mechanical durability: 8 Mcycles
- Tightening torque: Control circuit: 10.62 lbf.in (1.2 N.m) - on screw clamp terminals - with screwdriver flat 6 mm, Control circuit: 10.62 lbf.in (1.2 N.m) - on screw clamp terminals - with screwdriver Philips No 2, Power circuit: 106.19 lbf.in (12 N.m) - on connector hexagonal 0.16 in (4 mm)
- Connections - terminals: Control circuit: screw clamp terminals 2 cable(s) 0...0 in (1...2.5 mm) - cable stiffness: flexible - without cable end, Control circuit: screw clamp terminals 2 cable(s) 0...0 in (1...2.5 mm) - cable stiffness: flexible - with cable end, Control circuit: screw clamp terminals 2 cable(s) 0...0 in (1...2.5 mm) - cable stiffness: solid - without cable end, Control circuit: screw clamp terminals 1 cable(s) 0...0 in (1...2.5 mm) - cable stiffness: flexible - with cable end, Control circuit: screw clamp terminals 1 cable(s) 0...0 in (1...2.5 mm) - cable stiffness: flexible - without cable end, Control circuit: screw clamp terminals 1 cable(s) 0...0 in (1...2.5 mm) - cable stiffness: solid - without cable end, Power circuit: connector 1 cable(s) 0.02...0.19 in (10...120 mm) - cable stiffness: flexible - without cable end, Power circuit: connector 2 cable(s) 0.02...0.08 in (10...50 mm) - cable stiffness: flexible - without cable end, Power circuit: connector 1 cable(s) 0.02...0.19 in (10...120 mm) - cable stiffness: flexible - with cable end, Power circuit: connector 2 cable(s) 0.02...0.08 in (10...50 mm) - cable stiffness: flexible - with cable end, Power circuit: connector 1 cable(s) 0.02...0.19 in (10...120 mm) - cable stiffness: solid - without cable end, Power circuit: connector 2 cable(s) 0.02...0.08 in (10...50 mm) - cable stiffness: solid - without cable end
- Range: TeSys
- Mounting support: Plate, Rail
- [Ith] conventional free air thermal current: 200 A at <= 140 F (60 C) power circuit
- System Voltage: <= 300 V DC power circuit, <= 1000 V AC 25...400 Hz power circuit
- Operating rate: 2400 cyc/h at <= 140 F (60 C)
- Product name: TeSys D
- [Uc] control circuit voltage: 220 V AC 50/60 Hz
- Electrical durability: 0.8 Mcycles 200 A AC-1 at Ue <= 440 V, 0.95 Mcycles 115 A AC-3 at Ue <= 440 V
- Insulation resistance: > 10 MOhm signaling circuit
- motor power kW: 55 kW at 380...400 V AC 50/60 Hz AC-3, 75 kW at 500 V AC 50/60 Hz AC-3, 80 kW at 660...690 V AC 50/60 Hz AC-3, 30 kW at 220...230 V AC 50/60 Hz AC-3, 59 kW at 415...440 V AC 50/60 Hz AC-3, 65 kW at 1000 V AC 50/60 Hz AC-3, 18.5 kW at 400 V AC 50/60 Hz AC-4
- [Ie] rated operational current: 200 A (<= 140 F (60 C)) at <= 440 V AC AC-1 power circuit, 115 A (<= 140 F (60 C)) at <= 440 V AC AC-3 power circuit
- Utilization category: AC-1, AC-4, AC-3
- Control circuit voltage limits: 0.3...0.5 Uc drop-out at 131 F (55 C), AC 50/60 Hz, 0.8...1.15 Uc operational at 131 F (55 C), AC 50/60 Hz
- Poles description: 3P
- Overvoltage category: III
- Operating time: 6...20 ms opening, 20...50 ms closing
- Associated fuse rating: 200 A gG at <= 690 V coordination type 2 power circuit, 250 A gG at <= 690 V coordination type 1 power circuit, 10 A gG signaling circuit
- Control circuit type: AC 50/60 Hz
- Coil technology: Built-in bidirectional peak limiting diode suppressor
- inrush power in VA: 280...350 VA at 68 F (20 C) (cos ? 0.8) 60 Hz, 280...350 VA at 68 F (20 C) (cos ? 0.8) 50 Hz
- Pollution degree: 3
- Product or component type: Contactor
- hold-in power consumption in VA: 2...18 VA at 68 F (20 C) (cos ? 0.3) 60 Hz, 2...18 VA at 68 F (20 C) (cos ? 0.3) 50 Hz
- Ambient air temperature for operation: 23...140 F (-5...60 C)
- Heat dissipation: 3...8 W at 50/60 Hz
- Ambient air temperature for storage: -76...176 F (-60...80 C)
- Contactor application: Resistive load, Motor control
- Auxiliary contacts type: Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1, Type mirror contact (1 NC) conforming to IEC 60947-4-1
- Permissible ambient air temperature around the device: -40...158 F (-40...70 C) at Uc
- Signaling circuit frequency: 25...400 Hz
- Minimum switching current: 5 mA signaling circuit
- Fire resistance: 1562 F (850 C) conforming to IEC 60695-2-1
- Pole contact composition: 3 NO
- Minimum switching voltage: 17 V signaling circuit
- Flame retardance: V1 conforming to UL 94
- Non-overlap time: 1.5 ms on de-energisation (between NC and NO contact), 1.5 ms on energisation (between NC and NO contact)
- Mechanical robustness: Vibrations contactor open 2 Gn, 5...300 Hz, Vibrations contactor closed 4 Gn, 5...300 Hz, Shocks contactor closed 15 Gn for 11 ms, Shocks contactor open 6 Gn for 11 ms
- Power range: 30...50 kW 200...240 V 3 phases, 55...100 kW 380...440 V 3 phases, 55...100 kW 480...500 V 3 phases
- Motor power hp: 30 hp at 200/208 V AC 50/60 Hz 3 phases motors, 40 hp at 230/240 V AC 50/60 Hz 3 phases motors, 75 hp at 460/480 V AC 50/60 Hz 3 phases motors, 100 hp at 575/600 V AC 50/60 Hz 3 phases motors
- Motor starter type: Direct on-line contactor
- Contactor coil voltage: 220 V AC standard
- Auxiliary contact composition: 1 NO + 1 NC
- Irms rated making capacity: 1260 A at 440 V power circuit conforming to IEC 60947, 140 A AC signaling circuit conforming to IEC 60947-5-1, 250 A DC signaling circuit conforming to IEC 60947-5-1
- Rated breaking capacity: 1100 A at 440 V power circuit conforming to IEC 60947
- [Icw] rated short-time withstand current: 1100 A <= 104 F (40 C) 1 s power circuit, 100 A 1 s signaling circuit, 120 A 500 ms signaling circuit, 140 A 100 ms signaling circuit, 250 A <= 104 F (40 C) 10 min power circuit, 550 A <= 104 F (40 C) 1 min power circuit, 950 A <= 104 F (40 C) 10 s power circuit
- Average impedance: 0.6 mOhm at 50 Hz - Ith 200 A power circuit
- Power dissipation per pole: 24 W AC-1, 7.9 W AC-3
- Protective cover: With
- Product certifications: GL, RINA, UL, CSA, GOST, CCC, BV, LROS (Lloyds register of shipping), DNV
- Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1D115M7 . Santa Clara Systems carries 10,327 items from Telemecanique.
- Tesys D Contactor - 3p(3 No) - Ac-3 - <= 440 V 115 A - 220 V Ac 50/60 Hz Coil
Alternates
Common Typos
- LC1D11SM7
- LC1D1I5M7
- LC1D1ISM7
- LC1D1L5M7
- LC1D1LSM7
- LC1DI15M7
- LC1DI1SM7
- LC1DII5M7
- LC1DIISM7
- LC1DIL5M7
- LC1DILSM7
- LC1DL15M7
- LC1DL1SM7
- LC1DLI5M7
- LC1DLISM7
- LC1DLL5M7
- LC1DLLSM7
- LCID115M7
- LCID11SM7
- LCID1I5M7
- LCID1ISM7
- LCID1L5M7
- LCID1LSM7
- LCIDI15M7
- LCIDI1SM7
- LCIDII5M7
Appended Numbers
- LC1D115M7-A
- LC1D115M7-B
- LC1D115M7-C
- LC1D115M7-D
- LC1D115M7-E
- LC1D115M7-F
- LC1D115M7-G
- LC1D115M7-H
- LC1D115M7-I
- LC1D115M7-J
- LC1D115M7-K
- LC1D115M7-L
- LC1D115M7-M
- LC1D115M7-N
- LC1D115M7-O
- LC1D115M7-P
- LC1D115M7-Q
- LC1D115M7-R
- LC1D115M7-S
- LC1D115M7-T
- LC1D115M7-U
- LC1D115M7-V
- LC1D115M7-W
- LC1D115M7-X
- LC1D115M7-Y
- LC1D115M7-Z
Customers Are Also Buying
-
22-JBAB
Allen Bradley
-
140M-C2E-C10
Allen Bradley
-
872C-N20NP18-D4
Allen Bradley
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier