- Description:
- IP degree of protection: IP2x conforming to VDE 0106
- Standards: BS 5424
- Device short name: LC1K
- Width: 45 mm
- Height: 58 mm
- Depth: 57 mm
- Protective treatment: TC conforming to IEC 60068
- [Ui] rated insulation voltage: Power circuit: 600 V conforming to UL 508
- [Uimp] rated impulse withstand voltage: 8 kV
- Operating altitude: 2000 m without
- Mechanical durability: 10 Mcycles
- Connections - terminals: Spring terminals 1 cable(s) 0.751.5 mmsolid
- Range: TeSys
- Mounting support: Rail
- [Ith] conventional free air thermal current: 20 A (at 50 C) for power circuit
- Product name: TeSys K
- [Uc] control circuit voltage: 220...230 V AC 50/60 Hz
- Electrical durability: 0.3 Mcycles 20 A AC-1 at Ue <= 440 V
- Insulation resistance: > 10 MOhm for signalling circuit
- motor power kW: 4 kW at 480 V AC 50/60 Hz AC-3
- [Ie] rated operational current: 20 A (at <50 C) at <= 440 V AC AC-1 for power circuit
- Control circuit voltage limits: Operational: 0.8...1.15 Uc (at <50 C)
- Poles description: 3P
- Overvoltage category: III
- Operating time: 10...20 ms coil de-energisation and NO opening
- Associated fuse rating: 25 A gG at <= 440 V for power circuit
- Control circuit type: AC at 50/60 Hz
- Product or component type: Contactor
- Device application: Control
- Contactor application: Motor control
- Utilisation category: AC-3
- Power pole contact composition: 3 NO
- [Ue] rated operational voltage: Power circuit: 690 V AC 50/60 Hz
- Auxiliary contact composition: 1 NO
- Irms rated making capacity: 110 A AC for signalling circuit conforming to IEC 60947
- Rated breaking capacity: 110 A at 440 V conforming to IEC 60947
- [Icw] rated short-time withstand current: 115 A 50 C - 1 s for power circuit
- Average impedance: 3 mOhm - Ith 20 A 50 Hz for power circuit
- inrush power in VA: 30 VA (at 20 C)
- hold-in power consumption in VA: 4.5 VA (at 20 C)
- Heat dissipation: 1.3 W
- Maximum operating rate: 3600 cyc/h
- Auxiliary contacts type: type instantaneous 1 NO
- Signalling circuit frequency: <= 400 Hz
- Minimum switching current: 5 mA for signalling circuit
- Minimum switching voltage: 17 V for signalling circuit
- Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
- Non overlap distance: 0.5 mm
- Mechanical robustness: Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
- Net weight: 0.18 kg
- Ambient air temperature for storage: -5080 C
- Flame retardance: V1 conforming to UL 94
- Circularity Profile: End of Life Information
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1K12103M7 . Santa Clara Systems carries 10,327 items from Telemecanique.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.
Alternates
Common Typos
- LC1K121O3M7
- LC1K12I03M7
- LC1K12IO3M7
- LC1K12L03M7
- LC1K12LO3M7
- LC1K1Z103M7
- LC1K1Z1O3M7
- LC1K1ZI03M7
- LC1K1ZIO3M7
- LC1K1ZL03M7
- LC1K1ZLO3M7
- LC1KI2103M7
- LC1KI21O3M7
- LC1KI2I03M7
- LC1KI2IO3M7
- LC1KI2L03M7
- LC1KI2LO3M7
- LC1KIZ103M7
- LC1KIZ1O3M7
- LC1KIZI03M7
- LC1KIZIO3M7
- LC1KIZL03M7
- LC1KIZLO3M7
- LC1KL2103M7
- LC1KL21O3M7
- LC1KL2I03M7
Appended Numbers
- LC1K12103M7-A
- LC1K12103M7-B
- LC1K12103M7-C
- LC1K12103M7-D
- LC1K12103M7-E
- LC1K12103M7-F
- LC1K12103M7-G
- LC1K12103M7-H
- LC1K12103M7-I
- LC1K12103M7-J
- LC1K12103M7-K
- LC1K12103M7-L
- LC1K12103M7-M
- LC1K12103M7-N
- LC1K12103M7-O
- LC1K12103M7-P
- LC1K12103M7-Q
- LC1K12103M7-R
- LC1K12103M7-S
- LC1K12103M7-T
- LC1K12103M7-U
- LC1K12103M7-V
- LC1K12103M7-W
- LC1K12103M7-X
- LC1K12103M7-Y
- LC1K12103M7-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier