- Description: TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 40 A - 24 V AC 50/60 Hz coil
- Product weight: 1.87 lb(US) (0.85 kg)
- Range of product: TeSys D
- IP degree of protection: IP20 front face conforming to IEC 60529
- Standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508
- Device short name: LC1D
- Width: 2.17 in (55 mm)
- Height: 4.8 in (122 mm)
- Depth: 4.72 in (120 mm)
- Protective treatment: TH conforming to IEC 60068-2-30
- [Ui] rated insulation voltage: 600 V power circuit certifications CSA, 600 V power circuit certifications UL, 690 V power circuit conforming to IEC 60947-4-1, 690 V signaling circuit conforming to IEC 60947-1, 600 V signaling circuit certifications CSA, 600 V signaling circuit certifications UL
- [Uimp] rated impulse withstand voltage: Conforming to IEC 60947
- Operating altitude: 9842.52 ft. (3000 m) without derating in temperature
- Mechanical durability: 6 Mcycles
- Tightening torque: Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver flat 6 mm, Control circuit: 15.04 lbf.in (1.7 N.m) - on screw clamp terminals - with screwdriver Philips No 2, Power circuit: 70.8 lbf.in (8 N.m) - on EverLink BTR screw connectors - cable 0.04...0.05 in (25...35 mm) hexagonal 0.16 in (4 mm), Power circuit : 5 N.m - on EverLink BTR screw connectors - cable 1...25 mm hexagonal 4 mm
- Connections - terminals: Control circuit: screw clamp terminals 2 cable(s) 0...0 in (1...2.5 mm) - cable stiffness: flexible - with cable end, Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in (1...4 mm) - cable stiffness: flexible - without cable end, Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in (1...4 mm) - cable stiffness: flexible - without cable end, Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in (1...4 mm) - cable stiffness: flexible - with cable end, Control circuit: screw clamp terminals 1 cable(s) 0...0.01 in (1...4 mm) - cable stiffness: solid - without cable end, Control circuit: screw clamp terminals 2 cable(s) 0...0.01 in (1...4 mm) - cable stiffness: solid - without cable end, Power circuit : screw connection 2 cable(s) 1...25 mm - cable stiffness: flexible - with cable end, Power circuit : screw connection 2 cable(s) 1...25 mm - cable stiffness: solid - without cable end, Power circuit : screw connection 2 cable(s) 1...25 mm - cable stiffness: flexible - without cable end, Power circuit : screw connection 1 cable(s) 1...35 mm - cable stiffness: solid - without cable end, Power circuit : screw connection 1 cable(s) 1...35 mm - cable stiffness: flexible - without cable end, Power circuit : screw connection 1 cable(s) 1...35 mm - cable stiffness: flexible - with cable end
- Range: TeSys
- Mounting support: Plate, Rail
- [Ith] conventional free air thermal current: 60 A at <= 140 F (60 C) power circuit, 10 A at <= 140 F (60 C) signaling circuit
- System Voltage: <= 300 V DC power circuit, <= 690 V AC 25...400 Hz power circuit
- Operating rate: 3600 cyc/h at <= 140 F (60 C)
- Product name: TeSys D
- [Uc] control circuit voltage: 24 V AC 50/60 Hz
- Electrical durability: 1.5 Mcycles 40 A AC-3 at Ue <= 440 V, 1.4 Mcycles 60 A AC-1 at Ue <= 440 V
- Insulation resistance: > 10 MOhm signaling circuit
- motor power kW: 18.5 kW at 380...400 V AC 50/60 Hz AC-3, 22 kW at 500 V AC 50/60 Hz AC-3, 30 kW at 660...690 V AC 50/60 Hz AC-3, 11 kW at 220...230 V AC 50/60 Hz AC-3, 9 kW at 400 V AC 50/60 Hz AC-4, 22 kW at 415...440 V AC 50/60 Hz AC-3
- [Ie] rated operational current: 40 A (<= 140 F (60 C)) at <= 440 V AC AC-3 power circuit, 60 A (<= 140 F (60 C)) at <= 440 V AC AC-1 power circuit
- Utilization category: AC-3, AC-1, AC-4
- Control circuit voltage limits: 0.3...0.6 Uc drop-out at 140 F (60 C), AC 50/60 Hz, 0.8...1.1 Uc operational at 140 F (60 C), AC 50 Hz, 0.85...1.1 Uc operational at 140 F (60 C), AC 60 Hz
- Poles description: 3P
- Overvoltage category: III
- Operating time: 12...26 ms closing, 4...19 ms opening
- Associated fuse rating: 80 A gG at <= 690 V coordination type 1 power circuit, 80 A gG at <= 690 V coordination type 2 power circuit, 10 A gG signaling circuit conforming to IEC 60947-5-1
- Control circuit type: AC 50/60 Hz
- Coil technology: Without built-in suppressor module
- inrush power in VA: 140 VA at 68 F (20 C) (cos ? 0.75) 60 Hz, 160 VA at 68 F (20 C) (cos ? 0.75) 50 Hz
- Pollution degree: 3
- Product or component type: Contactor
- hold-in power consumption in VA: 13 VA at 68 F (20 C) (cos ? 0.3) 60 Hz, 15 VA at 68 F (20 C) (cos ? 0.3) 50 Hz
- Ambient air temperature for operation: 23...140 F (-5...60 C)
- Heat dissipation: 4...5 W at 50/60 Hz
- Ambient air temperature for storage: -76...176 F (-60...80 C)
- Contactor application: Resistive load, Motor control
- Auxiliary contacts type: Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1, Type mirror contact (1 NC) conforming to IEC 60947-4-1
- Permissible ambient air temperature around the device: -40...158 F (-40...70 C) at Uc
- Signaling circuit frequency: 25...400 Hz
- Minimum switching current: 5 mA signaling circuit
- Fire resistance: 1562 F (850 C) conforming to IEC 60695-2-1
- Pole contact composition: 3 NO
- Minimum switching voltage: 17 V signaling circuit
- Flame retardance: V1 conforming to UL 94
- Non-overlap time: 1.5 ms on de-energisation (between NC and NO contact), 1.5 ms on energisation (between NC and NO contact)
- Mechanical robustness: Vibrations contactor open 2 Gn, 5...300 Hz, Vibrations contactor closed 4 Gn, 5...300 Hz, Shocks contactor open 10 Gn for 11 ms, Shocks contactor closed 15 Gn for 11 ms
- Power range: 7...11 kW 200...240 V 3 phases, 15...25 kW 380...440 V 3 phases, 15...25 kW 480...500 V 3 phases
- Motor power hp: 5 hp at 230/240 V AC 50/60 Hz 1 phase motors, 10 hp at 230/240 V AC 50/60 Hz 3 phases motors, 30 hp at 575/600 V AC 50/60 Hz 3 phases motors, 3 hp at 115 V AC 50/60 Hz 1 phase motors, 10 hp at 200/208 V AC 50/60 Hz 3 phases motors, 30 hp at 460/480 V AC 50/60 Hz 3 phases motors
- Motor starter type: Direct on-line contactor
- Contactor coil voltage: 24 V AC standard
- Auxiliary contact composition: 1 NO + 1 NC
- Irms rated making capacity: 800 A at 440 V power circuit conforming to IEC 60947, 140 A AC signaling circuit conforming to IEC 60947-5-1, 250 A DC signaling circuit conforming to IEC 60947-5-1
- Rated breaking capacity: 800 A at 440 V power circuit conforming to IEC 60947
- [Icw] rated short-time withstand current: 100 A 1 s signaling circuit, 120 A 500 ms signaling circuit, 140 A 100 ms signaling circuit, 320 A <= 104 F (40 C) 10 s power circuit, 720 A <= 104 F (40 C) 1 s power circuit, 72 A <= 104 F (40 C) 10 min power circuit, 165 A <= 104 F (40 C) 1 min power circuit
- Average impedance: 1.5 mOhm at 50 Hz - Ith 60 A power circuit
- Power dissipation per pole: 5.4 W AC-1, 2.4 W AC-3
- Protective cover: With
- Product certifications: UL, CCC, CSA, GOST
- Safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LC1D40AB7 . Santa Clara Systems carries 10,400 items from Telemecanique.
- Tesys D Contactor - 3p(3 No) - Ac-3 - <= 440 V 40 A - 24 V Ac 50/60 Hz Coil
Alternates
Common Typos
- 1C1D40A87
- 1C1D40AB7
- 1C1D4OA87
- 1C1D4OAB7
- 1CID40A87
- 1CID40AB7
- 1CID4OA87
- 1CID4OAB7
- 1CLD40A87
- 1CLD40AB7
- 1CLD4OA87
- 1CLD4OAB7
- IC1D40A87
- IC1D40AB7
- IC1D4OAB7
- LC1D40A87
- LC1D4OA87
- LC1D4OAB7
- LCID40A87
- LCID40AB7
- LCID4OA87
- LCID4OAB7
- LCLD40A87
- LCLD40AB7
- LCLD4OA87
- LCLD4OAB7
Appended Numbers
- LC1D40AB7-A
- LC1D40AB7-B
- LC1D40AB7-C
- LC1D40AB7-D
- LC1D40AB7-E
- LC1D40AB7-F
- LC1D40AB7-G
- LC1D40AB7-H
- LC1D40AB7-I
- LC1D40AB7-J
- LC1D40AB7-K
- LC1D40AB7-L
- LC1D40AB7-M
- LC1D40AB7-N
- LC1D40AB7-O
- LC1D40AB7-P
- LC1D40AB7-Q
- LC1D40AB7-R
- LC1D40AB7-S
- LC1D40AB7-T
- LC1D40AB7-U
- LC1D40AB7-V
- LC1D40AB7-W
- LC1D40AB7-X
- LC1D40AB7-Y
- LC1D40AB7-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier