- Description: Keyence Laser Sensor
- Weight: Approx. 80 g (with 2 m cable)
- Footnotes: *1 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less. 1 or 2 Units: -10 to 55C 14 to 131F, 3 to 10 Units: -10 to 50C 14 to 122F, 11 to 16 Units: -10 to 45C 14 to 113F *2 When more than 8 units connected, be sure to use supply voltage 24 VDC Ripple (P-P) 10% max. *3 When extended, the ambient usage temperature varies according to the following conditions. Be sure to mount units on a DIN rail (attached to a metal plate) and ensure that the output current is 20 mA or less. When 1 to 2 units: -10 to +55C 14 to 131F When 3 to 10 units: -10 to +50C 14 to 122F When 11 to 16 units: -10 to +45C 14 to 113F
- Type: Expansion unit (1 line)
- Main unit/expansion unit: Expansion unit (1 line)
- Applicable model: LV-S61/S41/S41L/S31/S71/S72
- Control output: NPN open-collector 2 channels, 40 VDC maximum, 100 mA or less per output
- Response time - ExceptLV-S31 - ULTRA: 4 ms
- Response time - ExceptLV-S31 - SUPER: 2 ms
- Response time - ExceptLV-S31 - TURBO: 500 ?s
- Response time - ExceptLV-S31 - FINE: 250 ?s
- Response time - ExceptLV-S31 - HSP: 80 ?s
- Response time - LV-S31standard mode: 500 ?s
- Response time - LV-S31standard mode - SPED2: 2 ms
- Response time - LV-S31standard mode - SPED3: 8 ms
- Response time - LV-S31standard mode - SPED4: 32 ms
- Response time - LV-S31High-speed mode: 250 ?s
- Control input: Light emission stop input, external calibration, set value bank selection input, or received light intensity shift input
- Number of interference prevention units - ULTRA: 4
- Number of interference prevention units - SUPER: 4
- Number of interference prevention units - TURBO: 2
- Number of interference prevention units - FINE: 2
- Number of interference prevention units - HSP: 0
- Unit expansion: Up to 16 expansion units can be connected (a total of 17 units).*1
- Rating - Power voltage: 12 to 24 VDC ripple (P-P) 10% max. Class 2*2
- Rating - Power consumption - Normal: 1.5 W or less (62.5 mA or less at 24 V)
- Environmental resistance - Ambient temperature: -10 to 55C 14 to 131F, No freezing*3
- Environmental resistance - Vibration: 10 to 55 Hz, 1.5 mm 0.06" double amplitude for 2 hours in each of the X, Y, and Z directions
- Material - Main unit: Main body, cover: Polycarbonate
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LV-12SA . Santa Clara Systems carries 2,103 items from Keyence.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.
Alternates
Common Typos
- 1V-125A
- 1V-12SA
- 1V-1Z5A
- 1V-1ZSA
- 1V-I25A
- 1V-I2SA
- 1V-IZ5A
- 1V-IZSA
- 1V-L25A
- 1V-L2SA
- 1V-LZ5A
- 1V-LZSA
- IV-125A
- IV-12SA
- IV-1ZSA
- LV-125A
- LV-1Z5A
- LV-1ZSA
- LV-I25A
- LV-I2SA
- LV-IZ5A
- LV-IZSA
- LV-L25A
- LV-L2SA
- LV-LZ5A
- LV-LZSA
Appended Numbers
- LV-12SA-A
- LV-12SA-B
- LV-12SA-C
- LV-12SA-D
- LV-12SA-E
- LV-12SA-F
- LV-12SA-G
- LV-12SA-H
- LV-12SA-I
- LV-12SA-J
- LV-12SA-K
- LV-12SA-L
- LV-12SA-M
- LV-12SA-N
- LV-12SA-O
- LV-12SA-P
- LV-12SA-Q
- LV-12SA-R
- LV-12SA-S
- LV-12SA-T
- LV-12SA-U
- LV-12SA-V
- LV-12SA-W
- LV-12SA-X
- LV-12SA-Y
- LV-12SA-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier