- Description: Flow Sensor
- Weight: Approx. 640 g (including mounting bracket)
- Response time: 0.5 s/1.0 s/ 2.5 s/ 5 s/ 10 s/ 30 s/ 60 s
- Supported pipe diameter: 1 1/2" (40 A), 44 to 52 (mm), 2" (50A), 52 to 64 (mm)
- Supported pipe materials: Metal pipe/Resin pipe
- Supported fluids: Various liquid [i.e. water (including DI), oils, chemicals, etc.]
- Supported fluid temperture: 0 to 85*C 32 to 185*F (no freezing on the pipe surface)
- Maximum rated flow: 1 1/2: (40 A): 400 L/min, 105.7 G/min. 2" (50 A): 500 L/min, 132.1 G/min
- Zero cut flow rate: 25 L/min (default)
- Display method: Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stabililty level indicator
- Display update cycle: Approx. 3 Hz
- Display resolution: 0.1/1 (default: 1) (L/min)
- Hysteresis: Variable
- Integrated flow unit display: 1/ 10/ 100/ 1000/ 10000 (default: 1) (L)
- Ingerated flow data storage cycle: Save to memory every 10 seconds
- Memory backup: EEPROM (data storage length: 10 years or longer, data read/write frequency: 1million times or more)
- Power I/O connector: M12 4-pin connector
- Input/Output (selectable) - Output (ch.1/ch.2): Control output/pulse output/error output (selectable, default: ch.1 control output/ ch.2 not used). NPN/PNP setting switchable, open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less
- Input/Output (selectable) - Analog output (ch.2): 4 to 20 mA / 0 to 20 mA (selectable, default: not used), load resistance 500 or less
- Input/Output (selectable) - External input (ch.2): Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (selectable. Default: not used). short-circuit current 1.5 mA or less, input time 20 ms or more
- Power source - Power supply voltage: 20 to 30 V DC, ripple (P-P) 10% max, Class2/LPS
- Protection circuit: Power supply reverse connection protection, power supply surge protection, each output short-circuit protection, each output surge protection
- Enviromental resistance - Enclosure rating: IP65/IP67 (IEC60529)
- Enviromental resistance - Ambient temperture: -10 to 60*C 14 to 140*F, no freezing
- Enviromental resistance - Ambient humidity: 35 to 85% RH, no condensation
- Enviromental resistance - Vibration resistance: 10 to 55 Hz, compound amplitude 1.5 mm 0.06", XYZ axes 2 hours for each axis
- Enviromental resistance - Shock resistance: 100 m/s/ 16 ms pulse, X, Y, Z 1000 times for each axis
- Material - Sensor main unit: PPS/PES/PBT/SUS303/SUS304/SUSXM7
- Material - Sensor surface: Rubber
- Material - Mounting bracket: SUS304/PA/POM/SUSXM7
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on FD-Q50C . Santa Clara Systems carries 2,109 items from Keyence.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.
Alternates
Common Typos
- FD-Q5OC
- FD-QS0C
- FD-QSOC
Appended Numbers
- FD-Q50C-A
- FD-Q50C-B
- FD-Q50C-C
- FD-Q50C-D
- FD-Q50C-E
- FD-Q50C-F
- FD-Q50C-G
- FD-Q50C-H
- FD-Q50C-I
- FD-Q50C-J
- FD-Q50C-K
- FD-Q50C-L
- FD-Q50C-M
- FD-Q50C-N
- FD-Q50C-O
- FD-Q50C-P
- FD-Q50C-Q
- FD-Q50C-R
- FD-Q50C-S
- FD-Q50C-T
- FD-Q50C-U
- FD-Q50C-V
- FD-Q50C-W
- FD-Q50C-X
- FD-Q50C-Y
- FD-Q50C-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier