- Description: Level Sensor | LK0264A-A-00KQPKG/US
- Electrical Design: Pnp/Npn
- Output Function: Normally Open / Closed; (Configurable)
- Material: Stainless Steel (1.4301 / 304); Stainless Steel (1.4404 / 316L); Fkm; Nbr; Pbt; Pc; Pa; Pp; Tpv
- Operating Voltage [V]: 12...30 Dc
- Set point SP [mm]: 25...200
- Reset point rP [mm]: 20...195
- In steps of [mm]: 5
- Ambient Temperature [C]: 0...60
- Media: Hydrous Coolants; Oils; Oil-Based Media; Water; Media Similar To Water
- Dielectric Constant Of The Medium: > 2
- Cannot Be Used For: Extremely Conductive Media; Adhering Media; Granulates; Bulk Material; Acids; Alkali; Hygienic Areas And Electroplating Applications
- Maximum Speed Of The Change Of Level [Mm/S]: 100
- Tank Pressure [Bar]: 0.5; (When Mounting With Mounting Accessories: E43001 - E43007, E43019)
- Medium Temperature [C]: 0...35; (With Climate Tube E43100: 35...65 C)
- Medium Temperature Short Time [C]: 0...90; (< 1 H)
- Current Consumption [Ma]: < 50
- Protection Class: Iii
- Reverse Polarity Protection: Yes
- Power-On Delay Time [S]: < 3
- Number Of Inputs And Outputs: Number Of Digital Outputs: 2
- Total Number Of Outputs: 2
- Output Signal: Switching Signal; Io-Link
- Number Of Digital Outputs: 2
- Max. Voltage Drop Switching Output Dc [V]: 2.5
- Permanent Current Rating Of Switching Output Dc [Ma]: 200
- Short-Circuit Protection: Yes
- Type Of Short-Circuit Protection: Thermal, Pulsed
- Overload Protection: Yes
- Factory Setting: Automatic Medium Detection
- Probe Length L [Mm]: 264
- Active Range A [Mm]: 195
- Inactive Range I1 / I2 [Mm]: 53 / 16
- Reference Point Op [Mm]: 69 - 82 - 94 - 106 - 118 - 130 - 143 - 155 - 167 - 179 - 191 - 204 - Off
- Hysteresis, Op [Mm]: 2
- Measuring Error [% Of The Final Value]: 5
- Repeatability: 2
- Resolution [Mm]: 5
- Parameter Setting Options: Hysteresis / Window; Normally Open / Closed; Switching Logic; Sp/Rp Position; Adjustment Op; Medium Selection; Offset Setting; Switch-On/Switch-Off Delay
- Communication Interface: Io-Link
- Transmission Type: Com2 (38,4 Kbaud)
- Io-Link Revision: 1.1
- Sdci Standard: Iec 61131-9
- Io-Link Device Id: 0X00028F
- Profiles: Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
- Sio Mode: Yes
- Required Master Port Class: A
- Process Data Analogue: 2
- Process Data Binary: 2
- Min. Process Cycle Time [Ms]: 3.2
- Storage Temperature [C]: -25...80
- Protection: Ip 67
- Emc: Din En 61000-6-2 Din En 61000-6-4
- Shock Resistance: Din En 60068-2-27 15 G (11 Ms)
- Vibration Resistance: Din En 60068-2-6 5 G (10...2000 Hz)
- Dimensions [Mm]: 16
- Materials (Wetted Parts): Pp
- Display: Display Unit 2 X Led, Green (Cm, Inch) Switching Status 2 X Led, Yellow Measured Values Alphanumeric Display, 4-Digit Parameter Setting Alphanumeric Display, 4-Digit
- Connection: Connector: 1 X M12; Contacts: Gold-Plated
- Alternate Manufacturer Name: IFM
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LK7022 . Santa Clara Systems carries 2,278 items from Efector.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.
Alternates
- LK0264A-A-00KQPKG/US
Common Typos
- 1K7022
- 1K702Z
- 1K70Z2
- 1K70ZZ
- 1K7O22
- 1K7O2Z
- 1K7OZ2
- 1K7OZZ
- IK7022
- IK702Z
- IK70Z2
- IK70ZZ
- IK7O22
- IK7O2Z
- IK7OZ2
- IK7OZZ
- LK702Z
- LK70Z2
- LK70ZZ
- LK7O22
- LK7O2Z
- LK7OZ2
- LK7OZZ
Appended Numbers
- LK7022-A
- LK7022-B
- LK7022-C
- LK7022-D
- LK7022-E
- LK7022-F
- LK7022-G
- LK7022-H
- LK7022-I
- LK7022-J
- LK7022-K
- LK7022-L
- LK7022-M
- LK7022-N
- LK7022-O
- LK7022-P
- LK7022-Q
- LK7022-R
- LK7022-S
- LK7022-T
- LK7022-U
- LK7022-V
- LK7022-W
- LK7022-X
- LK7022-Y
- LK7022-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier