- Description: module XPS-MP - 2 independent functions - 24 V DC
- Product weight: 0.71 lb(US) (0.32 kg)
- Range of product: Preventa Safety automation
- IP degree of protection: IP20 (terminals), IP40 (enclosure)
- Standards: DIN V VDE 801 + A1, EN/IEC 60204-1, EN/IEC 60947-1 + A11, EN/IEC 60947-5-1
- Width: 1.77 in (45 mm)
- Height: 3.9 in (99 mm)
- Depth: 4.49 in (114 mm)
- [Ui] rated insulation voltage: 300 V, degree of pollution 2 conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
- [Uimp] rated impulse withstand voltage: 4 kV overvoltage category III conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
- Connections - terminals: Captive screw clamp terminals, removable terminal block: 0.2...1 mm, 2 wires solid without cable end, Captive screw clamp terminals, removable terminal block: 0.2...1.5 mm, 2 wires flexible without cable end, Captive screw clamp terminals, removable terminal block: 0.2...2.5 mm, 1 wire flexible without cable end, Captive screw clamp terminals, removable terminal block: 0.2...2.5 mm, 1 wire solid without cable end, Captive screw clamp terminals, removable terminal block: 0.25...1 mm, 2 wires flexible with cable end, without bezel, Captive screw clamp terminals, removable terminal block: 0.25...2.5 mm, 1 wire flexible with cable end, with bezel, Captive screw clamp terminals, removable terminal block: 0.25...2.5 mm, 1 wire flexible with cable end, without bezel, Captive screw clamp terminals, removable terminal block: 0.5...1.5 mm, 2 wires flexible with cable end, with double bezel
- Mounting support: 35 mm symmetrical DIN rail
- [Ith] conventional free air thermal current: <= 20 A
- [Uc] control circuit voltage: 24 V
- [Us] rated supply voltage: 24 V DC (- 20...20 %)
- Associated fuse rating: 4 A gG relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200, 6 A fast blow relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
- Breaking capacity: 20 mA/24 V for static output circuit, 1.5 A/24 V - L/R = 50 ms, DC-13 relay output
- Function of module: Configuration 0: functions disabled (factory setting), Configuration 1: emergency stop monitoring 1-channel wiring, category 2, Configuration 10: enabling grip switch monitoring (3-position switch), category 4, Configuration 11: sensing mat and edges monitoring, category 3, Configuration 12: sensing mat and edges monitoring, category 3, Configuration 13: relay output safety light curtain monitoring, category 4, Configuration 14: coded magnetic switch monitoring, category 4, Configuration 15: coded magnetic switch monitoring, category 4, Configuration 2: emergency stop monitoring 1-channel wiring, category 2, Configuration 3: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4, Configuration 4: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4, Configuration 5: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4, Configuration 6: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4, Configuration 7: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4, Configuration 8: emergency stop monitoring 2-channel wiring, or guard monitoring, category 4, Configuration 9: guard monitoring for injection presses and blowing machines, category 4
- Product or component type: Safety controller with pre-defined function
- Synchronisation time between inputs: 0.5 s (configuration 13), 1.5 s (configuration 14), 1.5 s (configuration 15), 1.5 s (configuration 5), 1.5 s (configuration 6), 1.5 s (configuration 9), Unlimited (configuration 3), Unlimited (configuration 4), Unlimited (configuration 7), Unlimited (configuration 8)
- Ambient air temperature for operation: 14...131 F (-10...55 C)
- Safety module name: XPSMP
- power consumption in W: <= 5 W
- Ambient air temperature for storage: -13...185 F (-25...85 C)
- Safety module application: 2 independent functions
- Input protection type: Internal, electronic
- Safety use category: Category 4 maximum conforming to EN/IEC 60954-1
- Type of start: Automatic or unmonitored (configuration 1), Automatic or unmonitored (configuration 10), Automatic or unmonitored (configuration 11), Automatic or unmonitored (configuration 14), Automatic or unmonitored (configuration 3), Automatic or unmonitored (configuration 5), Automatic or unmonitored (configuration 7), Monitored (configuration 12), Monitored (configuration 13), Monitored (configuration 15), Monitored (configuration 2), Monitored (configuration 4), Monitored (configuration 6), Monitored (configuration 8), Monitored (configuration 9)
- Line resistance: 100 Ohm 2000 m
- Checks: Configuration (configuration 10), Configuration (configuration 13), Configuration (configuration 3), Configuration (configuration 4), Configuration (configuration 5), Configuration (configuration 6), Configuration (configuration 9)
- Number of safety circuits: 3 NO relays per function (6 NO total), volt-free
- Number of additional circuits: 3 solid state outputs
- Product certifications: BIA, CSA, UL
- Output thermal current: 2 A for 1 output and 4 A for the other 2 outputs relay, 3.3 A for all 3 outputs relay simultaneously, 6 A for 1 output and 2 A for the other 2 outputs relay
- Safety level: Can reach SIL 3 conforming to EN/IEC 62061, Can reach PL e/category 4 conforming to EN/ISO 13849-1
- Minimum output current: 10 mA relay output
- Minimum output voltage: 17 V relay output
- Response time on input open: < 30 ms
- Local signalling: 12 LEDs
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on XPSMP11123P . Santa Clara Systems carries 10,327 items from Telemecanique.
- Module Xps-Mp - 2 Independent Functions - 24 V Dc
Alternates
Common Typos
- XPSMP111Z3P
- XPSMP11I23P
- XPSMP11IZ3P
- XPSMP11L23P
- XPSMP11LZ3P
- XPSMP1I123P
- XPSMP1I1Z3P
- XPSMP1II23P
- XPSMP1IIZ3P
- XPSMP1IL23P
- XPSMP1ILZ3P
- XPSMP1L123P
- XPSMP1L1Z3P
- XPSMP1LI23P
- XPSMP1LIZ3P
- XPSMP1LL23P
- XPSMP1LLZ3P
- XPSMPI1123P
- XPSMPI11Z3P
- XPSMPI1I23P
- XPSMPI1IZ3P
- XPSMPI1L23P
- XPSMPI1LZ3P
- XPSMPII123P
- XPSMPII1Z3P
- XPSMPIII23P
Appended Numbers
- XPSMP11123P-A
- XPSMP11123P-B
- XPSMP11123P-C
- XPSMP11123P-D
- XPSMP11123P-E
- XPSMP11123P-F
- XPSMP11123P-G
- XPSMP11123P-H
- XPSMP11123P-I
- XPSMP11123P-J
- XPSMP11123P-K
- XPSMP11123P-L
- XPSMP11123P-M
- XPSMP11123P-N
- XPSMP11123P-O
- XPSMP11123P-P
- XPSMP11123P-Q
- XPSMP11123P-R
- XPSMP11123P-S
- XPSMP11123P-T
- XPSMP11123P-U
- XPSMP11123P-V
- XPSMP11123P-W
- XPSMP11123P-X
- XPSMP11123P-Y
- XPSMP11123P-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier