  • Description: current control relay RM17-J - range: 2..20 A
  • Product weight: 0.29 lb(US) (0.13 kg)
  • Range of product: Zelio Control
  • IP degree of protection: IP20(terminals) conforming to IEC 60529, IP30 (casing) conforming to IEC 60529
  • Standards: EN/IEC 60255-6
  • Width: 0.69 in (17.5 mm)
  • [Ui] rated insulation voltage: 400 V conforming to IEC 60664-1
  • Mechanical durability: 30000000 cycles
  • Tightening torque: 5.31...8.85 lbf.in (0.6...1 N.m) conforming to IEC 60947-1
  • Connections - terminals: Screw terminals 1 x 0.5...1 x 4 mm - AWG 20...AWG 11, solid cable without cable end, Screw terminals 2 x 0.5...2 x 2.5 mm - AWG 20...AWG 14, solid cable without cable end, Screw terminals 1 x 0.2...1 x 2.5 mm - AWG 24...AWG 12, flexible cable with cable end, Screw terminals 2 x 0.2...2 x 1.5 mm - AWG 24...AWG 16, flexible cable with cable end
  • Mounting support: 35 mm symmetrical DIN rail conforming to EN/IEC 60715
  • Operating rate: <= 360 operations/hour under full load
  • Vibration resistance: 0.35 mm (f = 5...57.6 Hz) conforming to IEC 60068-2-6, 1 gn (f = 57.6...150 Hz) conforming to IEC 60255-21-1
  • Shock resistance: 15 gn 11 ms conforming to IEC 60255-21-1
  • Electrical durability: 100000 cycles
  • Insulation resistance: > 500 MOhm at 500 V DC conforming to IEC 60255-5, > 500 MOhm at 500 V DC conforming to IEC 60664-1
  • Utilization category: AC-12 conforming to IEC 60947-5-1, AC-13 conforming to IEC 60947-5-1, AC-14 conforming to IEC 60947-5-1, AC-15 conforming to IEC 60947-5-1, DC-12 conforming to IEC 60947-5-1, DC-13 conforming to IEC 60947-5-1, DC-14 conforming to IEC 60947-5-1
  • Control circuit voltage limits: - 15 % + 10 % Un
  • [Us] rated supply voltage: 24...240 V AC/DC, 50/60 Hz +/- 10 %
  • Overvoltage category: III conforming to IEC 60664-1
  • Relative humidity: 95 % at 131 F (55 C) conforming to IEC 60068-2-30
  • Response time: < 200 ms in the event of a fault
  • Housing material: Self-extinguishing plastic
  • Dielectric test voltage: 2 kV AC 50 Hz
  • Maximum switching voltage: 250 V AC/DC
  • Immunity to micro breaks: 10 ms
  • Product or component type: Modular measurement and control relays
  • Electromagnetic compatibility: Emission standard for industrial environments conforming to EN/IEC 61000-6-4, Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3, Immunity for industrial environments conforming to NF EN/IEC 61000-6-2
  • Relay type: Current control relay
  • Supply voltage limits: 20.4...264 V AC/DC
  • Relay name: RM17JC
  • Product certifications: GOST, GL, C-Tick, UL, CSA
  • Relay monitored parameters: Overcurrent detection
  • power consumption in W: <= 1 W
  • Ambient air temperature for storage: -40...158 F (-40...70 C)
  • Time delay type: Without
  • Control circuit frequency: 40...70 Hz sinusoidal
  • Ambient air temperature for operation: -4...122 F (-20...50 C)
  • switching capacity in VA: 1250 VA
  • Output contacts: 1 C/O
  • Minimum switching current: 10 mA at 5 V DC
  • Nominal output current: 5:00 AM
  • power consumption in VA: <= 3 VA
  • Measuring cycle: <= 30 ms measurement cycle as true rms value
  • Measurement range: 2...20 A current
  • Hysteresis: 15 % fixed of threshold setting
  • Run-up delay at power-up: 0.5 s
  • Pollution degree: 3 conforming to IEC 60664-1
  • Measurement accuracy: +/- 10 % of the full scale value
  • Repeat accuracy: +/- 0.5 % input and measurement circuit
  • Non-dissipating shock wave: 4 kV
  • Measurement error: +/- 0.05 %/C with temperature variation, < 1 % over the whole range with voltage variation
  • Polarity: Yes DC
  • Threshold setting: 10...100 %
  • Input current: 100000 mA permanent at 25 C, 300000 mA non repetitive < 3 s at 25 C
  • Marking: CE : EMC 89/336/EEC, CE : 73/23/EEC
  • Insulation: Between supply and measurement
  • Operating position: Any position without derating
  • Local signaling: LED green power ON, LED yellow relay ON
  • Contacts material: Cadmium free
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on RM17JC00MW . Santa Clara Systems carries 10,327 items from Telemecanique.
  • Current Control Relay Rm17-J - Range: 2..20 A

Alternates

    Common Typos

    • RM17JC0OMW
    • RM17JCO0MW
    • RM17JCOOMW
    • RMI7JC00MW
    • RMI7JC0OMW
    • RMI7JCO0MW
    • RMI7JCOOMW
    • RML7JC00MW
    • RML7JC0OMW
    • RML7JCO0MW
    • RML7JCOOMW

    Appended Numbers

    • RM17JC00MW-A
    • RM17JC00MW-B
    • RM17JC00MW-C
    • RM17JC00MW-D
    • RM17JC00MW-E
    • RM17JC00MW-F
    • RM17JC00MW-G
    • RM17JC00MW-H
    • RM17JC00MW-I
    • RM17JC00MW-J
    • RM17JC00MW-K
    • RM17JC00MW-L
    • RM17JC00MW-M
    • RM17JC00MW-N
    • RM17JC00MW-O
    • RM17JC00MW-P
    • RM17JC00MW-Q
    • RM17JC00MW-R
    • RM17JC00MW-S
    • RM17JC00MW-T
    • RM17JC00MW-U
    • RM17JC00MW-V
    • RM17JC00MW-W
    • RM17JC00MW-X
    • RM17JC00MW-Y
    • RM17JC00MW-Z

    More Products Like This

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo