- Description: TeSys GB2 - thermal-magnetic circuit breaker - 1P + N - 4 A - Id = 52 A
- Product weight: 0.15 lb(US) (0.07 kg)
- IP degree of protection: IP20 conforming to IEC 60529
- Standards: IEC 60947-2, EN 60947-1, IEC 60947-1, EN 60947-2
- Device short name: GB2
- Width: 0.59 in (15 mm)
- Height: 2.91 in (74 mm)
- Depth: 2.64 in (67 mm)
- Protective treatment: TC
- [Uimp] rated impulse withstand voltage: 4 kV conforming to IEC 60947-2
- Operating altitude: 9842.52 ft. (3000 m)
- Mechanical durability: 8000 cycles
- Tightening torque: 10.62 lbf.in (1.2 N.m) - on connector
- Connections - terminals: Connector 1 cable(s) 0...0.01 in (0.75...6 mm) - cable stiffness : solid - without cable end, Connector 2 cable(s) 0...0.01 in (0.75...4 mm) - cable stiffness : solid - without cable end, Connector 1 cable(s) 0...0.01 in (0.75...4 mm) - cable stiffness : flexible - with cable end, Connector 2 cable(s) 0...0 in (0.75...2.5 mm) - cable stiffness : flexible - with cable end
- Range: TeSys
- Mounting support: Plate, Rail
- System Voltage: 48 V DC, 250 V AC 50/60 Hz conforming to IEC 60947-2
- Product name: TeSys GB2
- Electrical durability: 8000 cycles
- Utilization category: Category A conforming to IEC 60947-2, DC-12 conforming to IEC 60947-5-1, DC-13 conforming to IEC 60947-5-1
- Poles description: 1P + N
- Control type: Toggle
- Breaking capacity: Icu = 1 kAat 48 V DC conforming to IEC 60947-2, Icu = 6 kAat 110 V AC 50/60 Hz conforming to IEC 60947-2, Icu = 1.5 kAat 24 V DC conforming to IEC 60947-2, Icu = 3 kAat 230/240 V AC 50/60 Hz conforming to IEC 60947-2
- Mounting position: Horizontal, Vertical
- Mounting mode: By clips
- Product certifications: UL, NEMKO
- Product or component type: Circuit breaker
- Device application: Control
- [In] rated current: 4:00 AM
- Ambient air temperature for operation: -4...140 F (-20...60 C)
- Ambient air temperature for storage: -40...176 F (-40...80 C)
- Network type: AC/DC
- Fire resistance: 1760 F (960 C) conforming to IEC 60695-2-1
- Power dissipation per pole: 2 W
- Network frequency: 50/60 Hz conforming to IEC 60947-2
- [Ics] rated service short-circuit breaking capacity: 50 %at 110 V AC 50/60 Hz conforming to IEC 60947-2, 50 %at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
- Trip unit technology: Thermal-magnetic
- Magnetic tripping current: 52 A
- Mechanical robustness: Shocks 22 Gn for 20 ms conforming to IEC 60068-2-27, Vibrations 5 Gn, 5...110 Hz conforming to IEC 60068-2-6
- Quantity per set: Set of 6
- 9 mm pitches: 2
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on GB2CD09 . Santa Clara Systems carries 10,326 items from Telemecanique.
- Tesys Gb2 - Thermal-Magnetic Circuit Breaker - 1p + N - 4 A - Id = 52 A
Alternates
Common Typos
- 682CD09
- 682CDO9
- 68ZCD09
- 68ZCDO9
- 6B2CD09
- 6B2CDO9
- 6BZCD09
- 6BZCDO9
- G82CD09
- G82CDO9
- G8ZCD09
- G8ZCDO9
- GB2CDO9
- GBZCD09
- GBZCDO9
Appended Numbers
- GB2CD09-A
- GB2CD09-B
- GB2CD09-C
- GB2CD09-D
- GB2CD09-E
- GB2CD09-F
- GB2CD09-G
- GB2CD09-H
- GB2CD09-I
- GB2CD09-J
- GB2CD09-K
- GB2CD09-L
- GB2CD09-M
- GB2CD09-N
- GB2CD09-O
- GB2CD09-P
- GB2CD09-Q
- GB2CD09-R
- GB2CD09-S
- GB2CD09-T
- GB2CD09-U
- GB2CD09-V
- GB2CD09-W
- GB2CD09-X
- GB2CD09-Y
- GB2CD09-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier