- Description: A30-30-10 415-440V 50Hz / 440-460V 60Hz Contactor
- Product ID: 1SBL281001R8710
- Extended Product Type: 1SBL281001R8710
- Product Net Weight: 0.710 kg
- Product Net Width: 54 mm
- Product Net Height: 90 mm
- Product Net Depth: 108.3 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
- Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 C Close to Contactor for Storage -60 ... +80 C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 C Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 C
- Standards: Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): 8 kV
- Rated Insulation Voltage (U<sub>i</sub>): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
- Terminal Type: Screw Terminals
- Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz
- Number of Auxiliary Contacts NO: 1
- Number of Auxiliary Contacts NC: 0
- Connecting Capacity Main Circuit: Flexible with Cable End 2.5 ... 10 mm Rigid Cable 2.5 ... 16 mm
- GOST Certificate: GOST_POCCFRME77B07175
- Maximum Operating Altitude Permissible: 3000 m
- Rated Control Circuit Voltage (U<sub>c</sub>): 50 Hz 415 440 V 60 Hz 440 460 V
- Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
- Maximum Mechanical Switching Frequency: 3600 cycles per hour
- Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm
- Operate Time: Between Coil Energization and NO Contact Closing 8 ... 21 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms
- Number of Main Contacts NO: 3
- GL Certificate: DNV-GL_TAE00000TX
- Number of Main Contacts NC: 0
- Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 63 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
- Coil Consumption: Average Holding Value 50 / 60 Hz 12 V·A Average Holding Value 50 / 60 Hz 3 W Average Pull-in Value 50 Hz 125 V·A Average Pull-in Value 60 Hz 120 V·A
- Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at 55 C) C
- Connecting terminals (delivered in open position) Main poles: M 5 (+,-) pozidriv 2 screw with 2x (5.6x6.5 mm) connector
- EAN: 3471522071873
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85369085
- Package Level 1 Width: 101 mm
- Package Level 1 Length: 115 mm
- Package Level 1 Height: 61 mm
- Package Level 1 Gross Weight: 0.71 kg
- Package Level 1 EAN: 3471522071873
- Package Level 2 Units: 63 piece
- Package Level 3 Units: 576 piece
- Package Level 1 Units: 1 piece
- Rated Operational Voltage: Main Circuit 690 V
- Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 65 A acc. to IEC 60947-5-1, q = 40 C 16 A
- Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 40 C 55 A (690 V) 55 C 55 A (690 V) 70 C 39 A
- Rated Operational Current AC-3 (I<sub>e</sub>): (220 / 230 / 240 V) 55 C 33 A (380 / 400 V) 55 C 32 A (415 V) 55 C 32 A (440 V) 55 C 32 A (500 V) 55 C 28 A (690 V) 55 C 21 A
- Rated Operational Power AC-3 (P<sub>e</sub>): (220 / 230 / 240 V) 9 kW (380 / 400 V) 15 kW (415 V) 15 kW (440 V) 18.5 kW (500 V) 18.5 kW (690 V) 18.5 kW
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
- Rated Operational Current AC-15 (I<sub>e</sub>): (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
- Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 400 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 65 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 150 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 600 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 225 A for 0.1 s 140 A for 1 s 100 A
- Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour
- Rated Operational Current DC-13 (I<sub>e</sub>): (125 V) 1.1 / 138 A (24 V) 6 / 144 A (250 V) 0.55 / 138 A (48 V) 2.8 / 134 A (72 V) 2 / 144 A
- Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 20 g Closed, Shock Direction: B1 10 g Open, Shock Direction: B1 5 g Shock Direction: B2 15 g Shock Direction: C1 20 g Shock Direction: C2 20 g
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Instructions and Manuals: FPTC407722P0001
- BV Certificate: BV_2634H07559D0
- CB Certificate: CB_FR_602227A
- CCC Certificate: CCC_2013010304615752 CCC_2004010309133982
- CSA Certificate: CSA_1033838_LR056745
- cUL Certificate: UL_071301E39231
- Data Sheet, Technical Information: 1SBC100122C0202_Ch02
- Declaration of Conformity - CE: 1SBD250801U1000
- DNV Certificate: DNV-GL_TAE00000TX
- EAC Certificate: EAC_RU C-FR ME77 B01010
- LOVAG Certificate: LOVAG_FR97008
- LR Certificate: LRS_9830011E4
- RINA Certificate: RINA_ELE128713XG001
- RMRS Certificate: RMRS_0507015250
- RoHS Information: 1SBD350054R1000
- UL Certificate: UL_071301E39231
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- ETIM 6: EC000066 - Power contactor, AC switching
- UNSPSC: 39121529
- Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on A30-30-10-87 . Santa Clara Systems carries 36,879 items from ABB.
- 1 Built-In Auxiliary Contact
- Front And Side-Mounted Add-On Auxiliary Contact Blocks - Control Circuit: Ac Operated With Laminated Magnet Circuit - Accessories: A Wide Range Of Accessories Is Available.
- A30 Contactors Are Mainly Used For Controlling 3-Phase Motors And Generally For Controlling Power Circuits Up To 690 V Ac Or 220 V Dc. The Contactors Can Also Be Used For Many Other Applications Such As Isolation
- Capacitor Switching
- Lighting. The A... Series 1-Stack 3-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 3 Main Poles
Alternates
- 1SBL281001R8710
- A30 30 10 87
- A30301087
Common Typos
- A30-30-10-B7
- A30-30-1O-87
- A30-30-1O-B7
- A30-30-I0-87
- A30-30-I0-B7
- A30-30-IO-87
- A30-30-IO-B7
- A30-30-L0-87
- A30-30-L0-B7
- A30-30-LO-87
- A30-30-LO-B7
- A30-3O-10-87
- A30-3O-10-B7
- A30-3O-1O-87
- A30-3O-1O-B7
- A30-3O-I0-87
- A30-3O-I0-B7
- A30-3O-IO-87
- A30-3O-IO-B7
- A30-3O-L0-87
- A30-3O-L0-B7
- A30-3O-LO-87
- A30-3O-LO-B7
- A3O-30-10-87
- A3O-30-10-B7
- A3O-30-1O-87
Appended Numbers
- A30-30-10-87-A
- A30-30-10-87-B
- A30-30-10-87-C
- A30-30-10-87-D
- A30-30-10-87-E
- A30-30-10-87-F
- A30-30-10-87-G
- A30-30-10-87-H
- A30-30-10-87-I
- A30-30-10-87-J
- A30-30-10-87-K
- A30-30-10-87-L
- A30-30-10-87-M
- A30-30-10-87-N
- A30-30-10-87-O
- A30-30-10-87-P
- A30-30-10-87-Q
- A30-30-10-87-R
- A30-30-10-87-S
- A30-30-10-87-T
- A30-30-10-87-U
- A30-30-10-87-V
- A30-30-10-87-W
- A30-30-10-87-X
- A30-30-10-87-Y
- A30-30-10-87-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier